Weil-McLain manual BCP-3 Plumbing Diagrams

Page 15

BCP-3 Installation and Operation Manual

BCP-3 Plumbing Diagrams

 

Outdoor

 

 

BCP-3

 

 

 

SYSTEM

=

 

 

147F

 

 

TARGET

=

 

 

150F

 

 

Sensor

Boiler

 

SYS

DHW

3)

 

 

Pump

Pump

 

Output 1

Output 2

Output 3

 

 

 

 

 

 

 

 

 

 

 

SET

 

 

 

White Wires (Output

Piping 1 On/Off Boiler +

 

} System Sensor

} Outdoor Sensor

} DHW Call Dry Contact

} Enable Dry Contact

} Setback Dry Contact

System Pump + DHW Pump

 

Yellow(OutputWires1)

System

T1 COM

T2 COM

T3+

T3-

EXT+ EXT-

P+ P- COM 24VAC

Pump

Building

 

 

 

 

 

 

 

2)

Heat

 

System

 

 

 

 

 

(Output

NOTES:

 

Sensor

 

 

 

 

 

 

 

 

 

 

 

 

• The BCP-3 does not source any output power to any of its

 

 

 

 

 

 

 

relays. A power source must supply pumps with power and

 

 

 

 

 

 

 

Wires

the control can break the hot leg.

 

Boiler

 

 

 

 

 

• Weil McLain recommends using a separate power source

 

 

 

 

 

 

to the control from any pumps, boilers, heavy electric

 

 

 

 

 

 

 

Blue

equipment.

 

 

 

 

 

 

 

• When wiring a sensor to the BCP-3, connect the Shield to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the COM terminal on the BCP-3 end. DO NOT connect

 

 

 

 

 

 

 

 

the Shield at the sensor end.

 

 

 

 

 

 

 

 

• Weil McLain is aware that each installation is unique.

 

 

 

 

 

DHW Pump

 

 

 

 

Thus, any wiring or piping diagrams in this document

 

 

 

 

 

 

 

 

 

 

are to represent control operation concept only.

 

 

 

 

Aquastat

DHW

Indirect

BCP-3

SYSTEM

=

147F

 

TARGET

=

150F

 

Boiler

SYS

DHW

3

Output 1

OutputPump

2 OutputP mp

Outdoor

Sensor

 

 

 

 

 

SET

 

 

 

 

 

1)

2)

WhiteWires

(Output3)

 

 

 

 

 

 

 

Wires(Output

Wires(Output

T1 COM T2

COM T3+

-T3 EXT+

-EXT

P+ -P

COM 24VAC

 

 

 

 

 

SensorSystem

SensorOutdoor

ContactDryCallDHW

ContactDryEnable

ContactDrySetback

 

Piping 3 On/Off Boilers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

} } } } }

 

 

Yellow

Blue

 

 

 

 

 

 

 

System

 

Building

 

 

 

 

 

 

 

 

Pump

 

 

 

 

 

 

 

 

 

 

 

Heat

 

 

 

 

 

 

 

 

System

 

 

 

 

 

 

 

 

 

 

Sensor

 

 

Boiler1

 

 

Boiler2

 

 

Boiler3

Aquastat

 

 

 

 

 

 

 

 

 

 

DHW

 

 

 

 

 

 

 

 

 

 

Indirect

 

 

 

 

 

 

 

 

 

 

DHW

 

 

 

 

 

 

 

 

 

 

Pump

15

Image 15
Contents Hydronic Multi-Stage Boiler Control BCP-3DHW Pump Operation Operation ConceptBoiler Operation System Pump OperationHeating System Sensor HSS Installation T1, COM WiringWiring Input Terminals Wiring Power InputWiring Outputs Output Mode Table Wiring the Boiler OutputWiring the System and DHW Pump Outputs BCP-3 BCP-3 Output Modes WiringStartup Menu MenusStartup Options Button and Navigating MenusOperating Menu Options Click SET Button Setting the Control to Factory DefaultDefault Display Set Point Available when Startup Control Mode = Set PointSet Point/Cutoff SET /Set Point/Out. Reset/Cutoff Custom Reset RatioOptions From -40ºF/-22ºC to +40ºF/+22ºC Default 0ºF/0ºC Options Off, 30ºF/0ºC to 75ºF/25ºC, On Default 60ºF/16ºCStage Menu Options SET /Set Point/Out. Reset/Min. TgtSET /Set Point/Out. Reset/Max. Tgt Settings/StageSettings/Stage/Lead/Rotate Single On/Off Boiler and System Pump SettingsRun-On Not Available for 3-On/Off Output Mode Options Output 1, Output 2, or Output Default OutputBoost Enable/Disable Tstat InputDomestic Hot Water DHW Priority SetbackTroubleshooting BCP-3 Plumbing Diagrams Specifications