When draining the water | When draining the water |
|
| ||
tub float is not open | tub the float is not open |
|
| ||
within 8 minutes | within 4 hours |
|
| ||
|
|
|
|
|
|
Red |
| Red |
| Drain valve | Check/clean or |
flashes |
| lights |
| blocked/defective or | replace drain valve. |
|
|
|
| clogged. |
|
|
|
|
|
|
|
|
|
|
| Siphon clogged. | Clean siphon. |
|
|
|
|
|
|
|
|
|
| Relay defective | Replace control |
|
|
|
| board. | |
|
|
|
|
|
|
|
|
|
| Level sensor stucked | Clean/Replace |
|
|
|
| or short circuited. | level sensor. |
|
|
|
|
|
|
|
|
|
| Backpressure in the | Install special |
|
|
|
| siphon. | siphon. |
|
|
|
|
|
|
Conductivity of the water in | Conductivity of the water |
|
| ||
the tub too high | in the tub too high |
|
| ||
Red |
| Red |
| Conductivity after | Increase the |
flashes |
| lights |
| draining, restart or | nominal value or |
|
|
|
| cleaning | enhance water |
|
|
|
| cycle during 10 | quality. |
|
|
|
| minutes higher than |
|
|
|
|
| the set nominal value. |
|
|
|
|
|
|
|
|
|
|
| Conductivity sensor | Replace |
|
|
|
| defective. | conductivity sensor. |
|
|
|
|
|
|
|
|
|
| Conductivity | Replace |
|
|
|
| transmitter defective. | conductivity |
|
|
|
|
| transmitter. |
|
|
|
|
|
|
10-30
Page 31