PERIODIC MAINTENANCE

Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti- browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system. If spray jets become clogged, remove the spray tips, wash them thoroughly, and blow-dry.

NOTE: Do not use pins, wire, etc. to clean nozzles as this could destroy spray pattern.

Periodically inspect all hoses, electrical cables and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. If the cable insulation is broken or frayed, repair or replace it immediately. Don’t take chances with electrical fire or shock.

MAINTENANCE

DAILY / REGULAR MAINTENANCE

Before making any adjustments or repairs to the machine, disconnect the power cord from electrical source.

1.Empty unused cleaning solution from the solution tank.

2.Inspect and clean filter screen in solution tank.

3.Flush pumping system with 4 or 7 liters of clean, hot water.

4.After each use, rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a 1-10 bleach to water solution. Waste water should be disposed of properly.

5.Check for and remove any lint or debris around vac shoe.

6.Check spray jets for full spray pattern.

7.Remove lint and dirt build-up from brush and housing. NOTE: Brush removal.

a.To remove brush, grab and pull brush out from end opposite drive belt (operator’s right). Remove other end from brush driver.

b.To install brush, line up slots in brush core with pin in driver on drive belt side (operator’s left) and push brush onto driver. Then snap bearing end (opposite end) of brush into retaining clip.

8.Check cooling air screen (located on frame behind left wheel) for lint or debris.

9.Check float and shut-off screen and clean as necessary.

NOTE: Always store machine with brush in “Store” position.

86038280 04/04/07

4-3ENG

Image 21
Contents Carpet Extractor Date of Purchase Serial Number Sales Representative # Machine Data LOGTable of Contents HOW to USE this Manual Connect to a properly grounded outlet Important Safety InstructionsWhen Servicing Machine For SafetyHazard Intensity Level Hazard Intensity LevelThis Product is for Commercial USE Only Grounding InstructionsElectrical Extension CordsDIMENSION/CAPACITY Technical SpecificationsVacuum Motor Switch. Turns on vacuum motor CONTROLS/COMPONENT LocationsElectrical Cord 3ENG 4ENG Incorrect Operations6ENG Filling Operations Filling the ClipperChemicals OFF Cleaning Procedure9ENG 10ENG Accessory Tool Usage Turn off all switches and unplug machine MaintenanceRemove recovery tank Remove the 2 screws that fasten the solutionSolution Pump Replacement Pump Replacement Parts for Shurflo 100 psi 86026400 PRV noBelt Replacement Daily / Regular Maintenance Periodic MaintenanceProblem Cause Solution Troubleshooting Chart5ENG