Windsor CLP12IS manual Maintenance, Turn off all switches and unplug machine, Remove recovery tank

Page 19

MAINTENANCE

Vacuum Motor Carbon Brushes Replacement (Ametek)

ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS.

VACUUM MOTOR REPLACEMENT

1.

Turn off all switches and unplug machine.

2.

Remove recovery tank.

3.

Remove the (2) screws that fasten the solution

Carbon Brushes

End Cap

WARNING: The green ground wire must be

attached for safe operation. See wiring diagram.

 

tank to the frame, and tilt tank back to expose

 

the inside of the frame.

4.

Locate the vacuum motor wires and disconnect

 

at the connector. Close the solution tank.

5.

Remove the (6) screws holding the vacuum

 

motor cover 86003080 – PRV NO. 27809) to the

 

solution tank.

6.

Remove the vacuum motor.

7.

Reverse process to install vacuum motor.

Vacuum Motor Carbon Brushes Replacement (Windsor)

 

End Cap

Carbon

WARNING: The green

Brushes

ground wire must be

 

attached for safe operation.

 

See wiring diagram.

If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.

Important:

These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.

38 [9.5mm]

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.

Note: When replacing carbon brushes loosen wire terminal BEFORE removing screws on bracket.

Wire

Terminal

Wire Terminal

Note:

Place stop in groove.

If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.

Important:

These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.

3/8 (9.5mm)

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.

86038280 04/04/07

4-1ENG

Image 19
Contents Carpet Extractor Date of Purchase Serial Number Sales Representative # Machine Data LOGTable of Contents HOW to USE this Manual Connect to a properly grounded outlet Important Safety InstructionsHazard Intensity Level For SafetyWhen Servicing Machine Hazard Intensity LevelExtension Cords Grounding InstructionsThis Product is for Commercial USE Only ElectricalDIMENSION/CAPACITY Technical SpecificationsCONTROLS/COMPONENT Locations Vacuum Motor Switch. Turns on vacuum motorElectrical Cord 3ENG 4ENG Incorrect Operations6ENG Filling the Clipper Filling OperationsChemicals OFF Cleaning Procedure9ENG 10ENG Accessory Tool Usage Remove the 2 screws that fasten the solution MaintenanceTurn off all switches and unplug machine Remove recovery tankPump Replacement Parts for Shurflo 100 psi 86026400 PRV no Solution Pump ReplacementBelt Replacement Daily / Regular Maintenance Periodic MaintenanceProblem Cause Solution Troubleshooting Chart5ENG