CLEANING PROCEDURE

Start at wall closest to power outlet. For large areas flip handle and operate machine in parallel passes, overlapping brush path. Clean perimeter last.

During operation, observe the following: The Clipper is equipped with clear internal covers to facilitate operator viewing of dirty solution and vacuum air flow. During operation, observe the vacuum intake cover. Large amounts of water or foam entering the vacuum system can damage the vacuum motor. If you notice either condition, shut down the machine immediately. Empty recovery tank and/or add defoamer to recovery tank.

OR

STEP

1

STEP

4

SOLUTION

INTAKE COVER

VACUUM

INTAKE COVER

Use right side of machine for cleaning against walls.

STEP

5

After cleaning, turn off all controls, return brush to storage position and carefully unplug machine.

STEP

6

OFF

OFF OFF

3-9ENG

86038280 04/04/07

Image 16
Contents Carpet Extractor Machine Data LOG Date of Purchase Serial Number Sales Representative #Table of Contents HOW to USE this Manual Important Safety Instructions Connect to a properly grounded outletFor Safety When Servicing MachineHazard Intensity Level Hazard Intensity LevelGrounding Instructions This Product is for Commercial USE OnlyElectrical Extension CordsTechnical Specifications DIMENSION/CAPACITYCONTROLS/COMPONENT Locations Vacuum Motor Switch. Turns on vacuum motorElectrical Cord 3ENG 4ENG Operations Incorrect6ENG Filling the Clipper Filling OperationsChemicals Cleaning Procedure OFF9ENG 10ENG Accessory Tool Usage Maintenance Turn off all switches and unplug machineRemove recovery tank Remove the 2 screws that fasten the solutionPump Replacement Parts for Shurflo 100 psi 86026400 PRV no Solution Pump ReplacementBelt Replacement Periodic Maintenance Daily / Regular MaintenanceTroubleshooting Chart Problem Cause Solution5ENG