Windsor CLP12IE, CLP12IB, CLP12IA, CLP12IS manual CONTROLS/COMPONENT Locations, Electrical Cord

Page 9

8

9

4

5

6

7

2

3

10

CONTROLS/COMPONENT LOCATIONS

1.Main Handle. Used to pull and maneuver machine.

2.Handle Adjustment. Used to adjust height of handle, and allow machine to be used in “PUSH” or “PULL orientation.

3.Electrical Cord.

4.Solution Switch. Turns on pump. Continuous position (bottom) activates electro-valve to dispense solution to floor through jets. Intermittent position (up) requires operator to depress 1 of 3 trigger switches to dispense solution. Center position is off.

5.Brush Motor Switch. Turns on brush motor.

6.Vacuum Motor Switch. Turns on vacuum motor.

7.Trigger Switches. Activates electro-valve to dispense solution to floor through jets when solution switch is in the intermittent position.

8.Brush Motor Circuit Breaker. 4 amp. Breaker protecting brush motor.

9.Vacuum Motor Circuit Breaker. 7 amp. Breaker protecting vacuum motor.

10.Recovery Dump Hose. Facilitates draining dirty cleaning solution.

86038280 04/04/07

3-2ENG

Image 9
Contents Carpet Extractor Date of Purchase Serial Number Sales Representative # Machine Data LOGTable of Contents HOW to USE this Manual Connect to a properly grounded outlet Important Safety InstructionsWhen Servicing Machine For SafetyHazard Intensity Level Hazard Intensity LevelThis Product is for Commercial USE Only Grounding InstructionsElectrical Extension CordsDIMENSION/CAPACITY Technical SpecificationsVacuum Motor Switch. Turns on vacuum motor CONTROLS/COMPONENT LocationsElectrical Cord 3ENG 4ENG Incorrect Operations6ENG Filling Operations Filling the ClipperChemicals OFF Cleaning Procedure9ENG 10ENG Accessory Tool Usage Turn off all switches and unplug machine MaintenanceRemove recovery tank Remove the 2 screws that fasten the solutionSolution Pump Replacement Pump Replacement Parts for Shurflo 100 psi 86026400 PRV noBelt Replacement Daily / Regular Maintenance Periodic MaintenanceProblem Cause Solution Troubleshooting Chart5ENG