Windsor CLP12IB, CLP12IE, CLP12IA, CLP12IS manual Solution Pump Replacement, Belt Replacement

Page 20

MAINTENANCE

SOLUTION PUMP REPLACEMENT

1.Turn off all switches and unplug the machine.

2.Remove recovery tank.

3.Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.

4.Remove solution hoses from fittings in pump.

5.Remove the (2) screws that fasten the pump to the frame.

6.Reverse process to install pump.

Pump Replacement Parts for Shurflo 100 psi (86026400 – PRV NO. 65254)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump Head

 

Pressure Switch

 

Valve Asm

 

 

 

Diaphram

86251040

 

86161980

 

86258830 - PRV NO. 84161

86235100 - PRV NO. 29206

PRV NO. 65187

PRV NO. 42-809332

 

 

 

 

 

 

 

 

Pump Head

Pump Replacement Parts for Flojet 100 psi 230v (86004770 – PRV NO. 47477) Motor

86247370 - PRV NO. 53246

86251090 – PRV NO. 65204

Valve Asm

Diaphragm

86258860 - PRV NO. 84166

86235120 - PRV NO. 29219

ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE

FOLLOWING REPAIRS.

BELT REPLACEMENT

1.Turn off all switches and unplug machine.

2.Remove recovery tank and brush.

3.Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.

4.Loosen the (4) screws that hold the brush motor in place and slide motor forward to release tension in belt.

5.Remove the (2) screws that fasten the vacuum shoe links (86227350 - PRV NO. 05016) to the brush housing.

6.Remove the (3) screws that fasten the side plate (86249420 – PRV NO. 62759) to the brush housing to remove belt. NOTE: All components associated with driving the brush will come out with the side plate.

7.Reverse process to install belt.

86249420

PRV NO. 62759

86227350

PRV NO. 05016

4-2ENG

86038280 04/04/07

Image 20
Contents Carpet Extractor Machine Data LOG Date of Purchase Serial Number Sales Representative #Table of Contents HOW to USE this Manual Important Safety Instructions Connect to a properly grounded outletFor Safety When Servicing MachineHazard Intensity Level Hazard Intensity LevelGrounding Instructions This Product is for Commercial USE OnlyElectrical Extension CordsTechnical Specifications DIMENSION/CAPACITYElectrical Cord Vacuum Motor Switch. Turns on vacuum motorCONTROLS/COMPONENT Locations 3ENG 4ENG Operations Incorrect6ENG Chemicals Filling OperationsFilling the Clipper Cleaning Procedure OFF9ENG 10ENG Accessory Tool Usage Maintenance Turn off all switches and unplug machineRemove recovery tank Remove the 2 screws that fasten the solutionBelt Replacement Solution Pump ReplacementPump Replacement Parts for Shurflo 100 psi 86026400 PRV no Periodic Maintenance Daily / Regular MaintenanceTroubleshooting Chart Problem Cause Solution5ENG