Wayne-Dalton series 3000 user manual Install Wired Infrared Safety Sensor Wall Mounting Brackets

Page 11

Step 14: Install Wired Infrared Safety Sensor Wall Mounting Brackets

Use the following instructions if your opener is equipped with Wired Infrared Safety Sensors. If you just installed the Wireless Infrared Safety Sen- sors go to step 19.

Select a mounting position 5 inches above the floor to center line of wall bracket. The sending and receiving units should be mounted inside the door opening to minimize any interference by the sun. However, the sensors should be mounted as close to the door track or inside edge of the door as possible to offer maxi- mum entrapment protection. It is very important that both wall brackets be mounted at the same height for proper alignment.

The brackets may be temporarily mounted to the jamb with a 1” flat head nail (provided), permanently mount the wall mounting bracket to both door jambs. In some installations it may be necessary to attach wooden spacers to the wall to achieve the required clear- ance. Expansion bolts (not included) may be required to attach brackets to walls constructed of materials other than wood or gyp- sum.

Step 15: Install Wired Infrared Safety Sensor Wall Mounting Brackets

Attach the “U” brackets to the wall brackets with a 1/4 -20 carriage bolt, washer and hex nut (provided). Insert the bolt from the inside of the “U” bracket and hand tighten only at this time.

11

Image 11
Contents Owner Installation Important Installation Instructions Page Features Important PRE-ASSEMBLY Check Positioning and Installing Front Wall Bracket Attaching Motor Power Head Unit to RailMounting Motor End of Opener Attach Unit to Front Wall BracketPositioning the Motor End of Operator Mounting Door Bracket Installing Light Installing Wired Wall Station if included Install Entrapment Warning Label Installing Deluxe Wireless Wall Station if includedInstall Wireless Infrared Safety Sensor Install Wireless Infrared Safety Sensor BracketInstall Wired Infrared Safety Sensor Wall Mounting Brackets Connecting Wired Infrared Safety Sensor to Opener Install Wiring for Wired Infrared Safety SensorConnecting Electrical Power Mount Wired Infrared Safety SensorsChanging Wireless Wall Station Code Wireless Wall Station Security Code Change and ProgrammingAlignment of the Wireless Infrared Safety Sensors Transmitter Security Code Change and Programming Alignment of the Wired Infrared Safety SensorsTwo Button Transmitter Security Code Change and Programming Programming Transmitter to Power Head UnitUpper Door Arm Positioning Setting Trolley Close Posi- tionConnecting Door Arm to Door Setting Door Opening Travel IMPORTANT! Test Contact Obstruction Sensing FeatureProgramming Wireless Keyless Entry If Included Infrared Safety Sensor Obstruction TestAdjustment # 1 Opening and Closing Force Installing Wireless Keyless Entry If IncludedAdjustment # 3 Positive Mechanical Door Lock Adjustment # 2 Contact Obstruction Sensing Closing DirectionImportant Safety Instructions Operation of Your Opener HOW to Operate the Wireless Keyless Entry if IncludedOpener Power Head Controls HOW to Operate the Wireless Wall Station If IncludedPage Once a Year Once a MonthTwice a Year Trouble Shooting Section Parts Breakdown Rail Assembly All Models Description Per Unit # Per Quantum Accessories Cut Template to Aid in Keyless Entry Installation See Step Limited Lifetime Warranty