Step 31: Installing Wireless Keyless Entry (If Included)

Install all wall controls out of the reach of children and in a location where the door can be seen before activating.

CAUTION: The keypad should be mounted a minimum of 5 feet from the floor to keep it out of the reach of small children.

Locate a convenient place to mount the Wireless Keyless Entry. Choose a convenient location that does not interfere with the normal opening and closing of the door. To keep keyless entry out of the reach of children, measure and mark a spot at least five feet up from the floor. Use the drill- ing template located on Page 32 to determine hole positions. Drill 5/64” pilot holes 3/4" deep at each screw location.

Snap open the Wireless Keyless Entry case with a coin. Se- cure keyless entry base into wood wall framing using the two screws provided. Snap the front case half with the base.

Remove paper backing from instruction label and apply to a clean surface inside garage.

NOTE: Two screws are included for mounting to wood structures. Ensure proper hardware is used for mounting to other materials.

Battery Replacement: Under normal operating conditions, the batteries should be changed once every 12 months. Dispose used batteries properly. To change batteries, snap open case with a coin and remove old batteries. Insert two CR2032 or equivalent coin cell batteries and snap case together.

ADJUSTMENTS

Adjustment # 1 Opening and Closing Force

This garage door opener is built with a safety system that allows the door to reverse in the close direction and stop in the open direction. This must be adjusted so your opener does not use excessive force in the down direction or react to the weight of the door during upward travel.

CLOSING FORCE ADJUSTMENT

To help determine that the closing door force is not excessive, grasp the door handle or bottom edge during downward travel. The opener should REVERSE to this force. NOTE: Do not stand under door during this test.

To adjust the closing force follow one of the two methods listed below.

Method A (manual)

1.Turn the FORCE ADJ. (see illustration) counter clockwise to decrease force and repeat reversal test until door reacts properly.

Method B (computer assisted)

1.Operate the door to the fully open position.

2.Turn the FORCE ADJ. (see illustration) counter clockwise to the minimal force setting.

3.Press the PROGRAM SWITCH button two times or the PROGRAM button on the Wireless Wall Station (if included) until the LED turns on solid (5 sec.). The STATUS LED and the overhead lamp will flash on and off at a slow rate.

4.Operate the door to the fully closed position.

5.Turn the FORCE ADJ. clockwise until the STATUS LED flickers or just turns off.

6.Press the PROGRAM SWITCH once to confirm setting.

21

Image 21
Contents Owner Installation Important Installation Instructions Page Features Important PRE-ASSEMBLY Check Positioning and Installing Front Wall Bracket Attaching Motor Power Head Unit to RailAttach Unit to Front Wall Bracket Positioning the Motor End of OperatorMounting Motor End of Opener Installing Light Installing Wired Wall Station if includedMounting Door Bracket Install Entrapment Warning Label Installing Deluxe Wireless Wall Station if includedInstall Wireless Infrared Safety Sensor Install Wireless Infrared Safety Sensor BracketInstall Wired Infrared Safety Sensor Wall Mounting Brackets Connecting Wired Infrared Safety Sensor to Opener Install Wiring for Wired Infrared Safety SensorConnecting Electrical Power Mount Wired Infrared Safety SensorsChanging Wireless Wall Station Code Wireless Wall Station Security Code Change and ProgrammingAlignment of the Wireless Infrared Safety Sensors Transmitter Security Code Change and Programming Alignment of the Wired Infrared Safety SensorsTwo Button Transmitter Security Code Change and Programming Programming Transmitter to Power Head UnitSetting Trolley Close Posi- tion Connecting Door Arm to DoorUpper Door Arm Positioning Setting Door Opening Travel IMPORTANT! Test Contact Obstruction Sensing FeatureProgramming Wireless Keyless Entry If Included Infrared Safety Sensor Obstruction TestAdjustment # 1 Opening and Closing Force Installing Wireless Keyless Entry If IncludedAdjustment # 3 Positive Mechanical Door Lock Adjustment # 2 Contact Obstruction Sensing Closing DirectionImportant Safety Instructions Operation of Your Opener HOW to Operate the Wireless Keyless Entry if IncludedOpener Power Head Controls HOW to Operate the Wireless Wall Station If IncludedPage Once a Month Twice a YearOnce a Year Trouble Shooting Section Parts Breakdown Rail Assembly All Models Description Per Unit # Per Quantum Accessories Cut Template to Aid in Keyless Entry Installation See Step Limited Lifetime Warranty