Wayne-Dalton series 3000 user manual Install Wireless Infrared Safety Sensor Bracket

Page 10

Step 11: Install Wireless Infrared Safety Sensors Wall Mounting Bracket (If Included)

Select a mounting position 5 inches above the floor to center line of wall bracket. The EMITTER and TRANSPONDER units must be mounted inside the door opening to minimize any interference by the sun; however, the sensors must be mounted against the door track. The brackets may be temporarily mounted to the wall (or jamb) with a #8 X1/2” screw provided and should be in contact with the door track. Leave this screw in place after installation is completed to prevent accidental rotation of beam sensor. It is very important that both wall brackets be mounted at the same height for proper alignment.

Using the 1/4” x 3/4” lag screw provided, attach the wall mounting bracket to the wall. In some installations it may be necessary to attach wooden spacers to the wall to achieve the required clearance. Expansion bolts (not supplied) may be required to attach brackets to walls constructed of materials other than wood or gypsum.

Step 12: Install Wireless Infrared Safety Sensor Bracket

Attach the sensor bracket to the wall bracket using the two #8 x 1-1/2” screws supplied (make sure that the curved hooks protruding from the bracket are positioned over and in firm contact with the door track).

Note: This opener is equipped with state-of-the-art wire- less infrared safety sensors which are activated by door movement. It is extremely important to position and mount the sensor brackets in firm contact with the door track so that the sensors are immediately activated by the door movement.

Step 13: Install Wireless Infrared Safety Sensor

Open hinged cover on infrared safety sensors and remove battery protective paper strip.

Observe proper battery polarity, as illustrated, in battery compartment.

Identify the TRANSPONDER (green LED) and mount this unit on the right side (from inside the garage looking to the outside) of the garage door and the EMITTER (red LED) on the left side. This same right/left mounting procedure must be fol- lowed on two and three door installations.

Mount the infrared safety sensors to the sensor bracket keeping the soft washer between the sensor and sen- sor bracket and then place the conical washer, lock washer and hex nut on the extender bolt, as illustrated.

Keeping the sensors pointing in towards door and aimed at each other, tighten nut until there is enough friction to hold in place. Do not fully tighten until the final alignment has been completed.

10

Image 10
Contents Owner Installation Important Installation Instructions Page Features Important PRE-ASSEMBLY Check Attaching Motor Power Head Unit to Rail Positioning and Installing Front Wall BracketPositioning the Motor End of Operator Attach Unit to Front Wall BracketMounting Motor End of Opener Installing Wired Wall Station if included Installing LightMounting Door Bracket Installing Deluxe Wireless Wall Station if included Install Entrapment Warning LabelInstall Wireless Infrared Safety Sensor Bracket Install Wireless Infrared Safety SensorInstall Wired Infrared Safety Sensor Wall Mounting Brackets Install Wiring for Wired Infrared Safety Sensor Connecting Wired Infrared Safety Sensor to OpenerMount Wired Infrared Safety Sensors Connecting Electrical PowerWireless Wall Station Security Code Change and Programming Changing Wireless Wall Station CodeAlignment of the Wireless Infrared Safety Sensors Alignment of the Wired Infrared Safety Sensors Transmitter Security Code Change and ProgrammingProgramming Transmitter to Power Head Unit Two Button Transmitter Security Code Change and ProgrammingConnecting Door Arm to Door Setting Trolley Close Posi- tionUpper Door Arm Positioning IMPORTANT! Test Contact Obstruction Sensing Feature Setting Door Opening TravelInfrared Safety Sensor Obstruction Test Programming Wireless Keyless Entry If IncludedInstalling Wireless Keyless Entry If Included Adjustment # 1 Opening and Closing ForceAdjustment # 2 Contact Obstruction Sensing Closing Direction Adjustment # 3 Positive Mechanical Door LockImportant Safety Instructions HOW to Operate the Wireless Keyless Entry if Included Operation of Your OpenerHOW to Operate the Wireless Wall Station If Included Opener Power Head ControlsPage Twice a Year Once a MonthOnce a Year Trouble Shooting Section Parts Breakdown Rail Assembly All Models Description Per Unit # Per Quantum Accessories Limited Lifetime Warranty Cut Template to Aid in Keyless Entry Installation See Step