Step 20: Wireless Wall Station Security Code Change and Programming

Note: The following steps describe the process to change the Wireless Wall Station security code and to program the Wireless Wall Station to the opener.

IMPORTANT: You MUST change the Wireless Wall Station security code prior to programming the device to the power head unit.

WARNING: During programming the garage door may operate. Keep people and objects clear of the moving door to prevent door damage or possible personal injury.

Changing Wireless Wall Station Code

1.Press and hold the wall station’s light button for approximately 10 sec- onds until the wall station’s LED begins to blink rapidly. Release but- ton (LED will turn off).

2.Press and hold the wall station’s light button again (LED will light) for approximately 5 seconds until the wall station’s LED begins to blink rapidly. Release button.

3.LED will blink on and off three times indicating a successful security code change.

Programming Wireless Wall Station to Power Head Unit

Note: Do not press any button on the wall station until instructed

1.Press the PROGRAM Switch button located on the garage door power head unit once. The red PROGRAM STATUS light on the motor power head unit and overhead lamp will turn on and remain lit for one minute, indicating that it is ready to learn the wall station.

2.Press the light on/off button on the wall station. The PRO- GRAM STATUS light will turn on and off three times indicat- ing a successful learn.

3.Press the light on/off button on the wall station once more to confirm operation. The overhead light will toggle from on to off and from off to on.

At this point you will be able to activate the opener. It will open, but will not close the door. Before unit will close door the beam sensors must be aligned and programmed (next step).

Battery: If the LED (light) on wall station is dim or does not turn on, or the opener does not respond when a button is pressed, repeat “changing wireless wall station code” operation or replace the battery. To replace bat- tery, insert a coin in the coin slot and twist coin to access battery compartment. Replace battery with a single MN21 or equivalent battery. Snap case together after replacing. Reprogramming to the Power Head Unit may be necessary.

14

Image 14
Contents Owner Installation Important Installation Instructions Page Features Important PRE-ASSEMBLY Check Attaching Motor Power Head Unit to Rail Positioning and Installing Front Wall BracketMounting Motor End of Opener Attach Unit to Front Wall BracketPositioning the Motor End of Operator Mounting Door Bracket Installing LightInstalling Wired Wall Station if included Installing Deluxe Wireless Wall Station if included Install Entrapment Warning LabelInstall Wireless Infrared Safety Sensor Bracket Install Wireless Infrared Safety SensorInstall Wired Infrared Safety Sensor Wall Mounting Brackets Install Wiring for Wired Infrared Safety Sensor Connecting Wired Infrared Safety Sensor to OpenerMount Wired Infrared Safety Sensors Connecting Electrical PowerWireless Wall Station Security Code Change and Programming Changing Wireless Wall Station CodeAlignment of the Wireless Infrared Safety Sensors Alignment of the Wired Infrared Safety Sensors Transmitter Security Code Change and ProgrammingProgramming Transmitter to Power Head Unit Two Button Transmitter Security Code Change and ProgrammingUpper Door Arm Positioning Setting Trolley Close Posi- tionConnecting Door Arm to Door IMPORTANT! Test Contact Obstruction Sensing Feature Setting Door Opening TravelInfrared Safety Sensor Obstruction Test Programming Wireless Keyless Entry If IncludedInstalling Wireless Keyless Entry If Included Adjustment # 1 Opening and Closing ForceAdjustment # 2 Contact Obstruction Sensing Closing Direction Adjustment # 3 Positive Mechanical Door LockImportant Safety Instructions HOW to Operate the Wireless Keyless Entry if Included Operation of Your OpenerHOW to Operate the Wireless Wall Station If Included Opener Power Head ControlsPage Once a Year Once a MonthTwice a Year Trouble Shooting Section Parts Breakdown Rail Assembly All Models Description Per Unit # Per Quantum Accessories Limited Lifetime Warranty Cut Template to Aid in Keyless Entry Installation See Step