NOTE: Confirm that the door has stopped in the UP position as a result of the Upper Limit Switch and not because the Trolley has hit the open Stop Bolt, which is mounted in the Rail near the power head. The correct condition can be verified by observing that the openers Convenience Light does not flash after the fully open door comes to a stop. The faulty condition may also be confirmed visu- ally by checking to see if the Trolley is resting against the stop bolt.

To confirm final OPEN travel adjustment, activate the opener to bring door to fully open position. The opener light should not be flashing.

Step 29: Infrared Safety Sensor Obstruction Test

Test Procedure

Starting with the door in the fully open posi- tion, place a 6” high object on the floor pro- gressively one foot from the left side of the door; center of door and one foot from the right side of door (as illustrated). In each position, activation of the opener with the wall station should cause the door to move approximately one foot, stop and then reverse to fully open position. The same 6” high object when placed on the floor should also cause a closing door to reverse.

If the door does not respond properly to these tests, the Infrared Safety Sensors must be adjusted (refer to step 21 or 22 depending on type of sensors used). Repeat this test procedure. If the door opener still will not respond properly and fails this test, the door may cause severe injury or death. Have a qualified service person make repairs.

Step 30: Programming Wireless Keyless Entry (If Included)

NOTE: To facilitate installation, program the Keyless Entry station to the opener before mounting to wall.

WARNING: During programming the garage door may operate. Keep people and objects clear of the moving door to prevent door damage or possible personal injury.

NOTE: Before programming ensure garage door is in the “down” position.

1.Press the PROGRAM Switch button located on the garage door power head unit once. The red PROGRAM STATUS light on the motor power head unit and overhead lamp will turn on and remain lit for one minute, indicating that it is ready to learn the Keyless Entry.

2.Press the desired five digit PIN (PERSONAL IDENTIFICATION NUM- BER), Example 1-2-3-4-5. The PROGRAM STATUS light will turn on and off three times indicating a successful learn.

3.Wait five seconds and press any button on the keyless entry. The door will move to the up position.

NOTE: If an error is made entering codes, simply press and hold both the “7/8” and “9/0” buttons for two seconds. The Keyless Entry will reset. Repeat programming procedure again.

A single Wireless Keyless Entry device may be programmed to operate multiple garage door openers. To program addi- tional openers, repeat programming steps using a different five digit PIN for each additional opener

20

Image 20
Contents Owner Installation Important Installation Instructions Page Features Important PRE-ASSEMBLY Check Attaching Motor Power Head Unit to Rail Positioning and Installing Front Wall BracketMounting Motor End of Opener Attach Unit to Front Wall BracketPositioning the Motor End of Operator Mounting Door Bracket Installing LightInstalling Wired Wall Station if included Installing Deluxe Wireless Wall Station if included Install Entrapment Warning LabelInstall Wireless Infrared Safety Sensor Bracket Install Wireless Infrared Safety SensorInstall Wired Infrared Safety Sensor Wall Mounting Brackets Install Wiring for Wired Infrared Safety Sensor Connecting Wired Infrared Safety Sensor to OpenerMount Wired Infrared Safety Sensors Connecting Electrical PowerWireless Wall Station Security Code Change and Programming Changing Wireless Wall Station CodeAlignment of the Wireless Infrared Safety Sensors Alignment of the Wired Infrared Safety Sensors Transmitter Security Code Change and ProgrammingProgramming Transmitter to Power Head Unit Two Button Transmitter Security Code Change and ProgrammingUpper Door Arm Positioning Setting Trolley Close Posi- tionConnecting Door Arm to Door IMPORTANT! Test Contact Obstruction Sensing Feature Setting Door Opening TravelInfrared Safety Sensor Obstruction Test Programming Wireless Keyless Entry If IncludedInstalling Wireless Keyless Entry If Included Adjustment # 1 Opening and Closing ForceAdjustment # 2 Contact Obstruction Sensing Closing Direction Adjustment # 3 Positive Mechanical Door LockImportant Safety Instructions HOW to Operate the Wireless Keyless Entry if Included Operation of Your OpenerHOW to Operate the Wireless Wall Station If Included Opener Power Head ControlsPage Once a Year Once a MonthTwice a Year Trouble Shooting Section Parts Breakdown Rail Assembly All Models Description Per Unit # Per Quantum Accessories Limited Lifetime Warranty Cut Template to Aid in Keyless Entry Installation See Step