Wayne-Dalton series 3000 Mount Wired Infrared Safety Sensors, Connecting Electrical Power

Page 13

Step 18: Mount Wired Infrared Safety Sensors

Attach the sending and receiv- ing units to the “U” brackets by inserting their tabs into their respective holes.

Step 19: Connecting Electrical Power

To reduce the risk of electrical shock, connect the power cord only to a properly grounded 3 prong, 120 volt outlet.

Do not use an extension cord or change the plug in any way. At this point, plug in the opener to an electrical outlet. If the plug does not fit into the outlet, or you require permanent wiring, contact a qualified electrician to install the proper outlet. As soon as power is applied to the unit, the light on the opener will blink

once to indicate a successful self-check of the controls.

Check your local electrical codes. If your local code requires permanent wiring, use the specifications called for and in- structions illustrated.

Permanent Wiring Procedure

1.Ensure line cord is disconnected from power source.

2.Cut line cord 1/2” – 1” from strain relief / bushing.

3.Use needle nose pliers to remove strain relief bushing from frame. Squeeze tabs in on underside of bushing and work bushing out of hole.

4.Pull or strip off remaining section of outer insulation from three conductors of line cord. Pull the three wires into the operator. Discard remaining line cord.

5.Strip 1/2" of insulation from the black, white, and green wires.

6.Using UL/CSA approved wire nuts for 14-18AWG wire, wire nut black-black, white-white, and green-green (earth) wires securely.

7.Replace Power Head Unit cover.

DO NOT USE AN ELECTRICAL EXTENSION CORD OF ANY TYPE

13

Image 13
Contents Owner Installation Important Installation Instructions Page Features Important PRE-ASSEMBLY Check Positioning and Installing Front Wall Bracket Attaching Motor Power Head Unit to RailPositioning the Motor End of Operator Attach Unit to Front Wall BracketMounting Motor End of Opener Installing Wired Wall Station if included Installing LightMounting Door Bracket Install Entrapment Warning Label Installing Deluxe Wireless Wall Station if includedInstall Wireless Infrared Safety Sensor Install Wireless Infrared Safety Sensor BracketInstall Wired Infrared Safety Sensor Wall Mounting Brackets Connecting Wired Infrared Safety Sensor to Opener Install Wiring for Wired Infrared Safety SensorConnecting Electrical Power Mount Wired Infrared Safety SensorsChanging Wireless Wall Station Code Wireless Wall Station Security Code Change and ProgrammingAlignment of the Wireless Infrared Safety Sensors Transmitter Security Code Change and Programming Alignment of the Wired Infrared Safety SensorsTwo Button Transmitter Security Code Change and Programming Programming Transmitter to Power Head UnitConnecting Door Arm to Door Setting Trolley Close Posi- tionUpper Door Arm Positioning Setting Door Opening Travel IMPORTANT! Test Contact Obstruction Sensing FeatureProgramming Wireless Keyless Entry If Included Infrared Safety Sensor Obstruction TestAdjustment # 1 Opening and Closing Force Installing Wireless Keyless Entry If IncludedAdjustment # 3 Positive Mechanical Door Lock Adjustment # 2 Contact Obstruction Sensing Closing DirectionImportant Safety Instructions Operation of Your Opener HOW to Operate the Wireless Keyless Entry if IncludedOpener Power Head Controls HOW to Operate the Wireless Wall Station If IncludedPage Twice a Year Once a MonthOnce a Year Trouble Shooting Section Parts Breakdown Rail Assembly All Models Description Per Unit # Per Quantum Accessories Cut Template to Aid in Keyless Entry Installation See Step Limited Lifetime Warranty