Wayne-Dalton series 3000 user manual Adjustment # 2 Contact Obstruction Sensing Closing Direction

Page 22

OPENING FORCE ADJUSTMENT

To determine that the opening force is not excessive, grasp the door handle or bottom edge during upward travel. If the opener does not stop or is hard to hold, decrease the open force setting. The opener should STOP without using exces- sive force.

To change the opening force follow the procedure listed below.

1.Operate the door to the fully closed position.

2.Press the PROGRAM SWITCH button three times. The STATUS LED and the overhead lamp will flash on and off. The blink rate which corresponds to the force setting will consist of 1 to 5 fast blinks follow with a long pause between blink sets.

3.The first time an attempt is made to increase the force, the setting will begin at the lightest setting (1 blink).

4.To increase the force, press and release the door up/down button on any control (The STATUS LED will remain lit during button press).

5.Continue to press and release the door button until the desired force setting is achieved.

6.Press the PROGRAM SWITCH once to confirm setting.

Adjustment # 2 Contact Obstruction Sensing (Closing Direction)

The opener is designed to automatically reverse the door during closing travel whenever it comes in contact with an object up to the last 1 inch of travel above the floor. An object on the floor with a height less than 1” will cause the door to stop. (Test according to instructions on Step 27.)

If opener reverses properly with a 1” high solid test object laid flat on garage floor (Step 27) and stops without the solid test object in the fully closed position, proceed to Adjustment # 3.

When door comes in contact with a 1” high solid test object laid flat on garage floor and stops instead of reversing, reset the door close limits according to instruction in Step 27, adjusting until door reverses upon contact with the 1” high solid test object.

If door reverses when it comes in contact with the floor, reset the door close limits according to instruction in Step 27.

Adjustment # 3 Positive Mechanical Door Lock

The garage door opener is designed with an automatic mechanical locking system. This lock secures the door in the fully closed position.

To adjust, activate the door opener and allow the door to go to its fully closed position. Loosen the two screws on the rail stop and move it behind the chain latch assembly with a gap of 3/4” between “stop” and “latch”. Retighten screws.

22

Image 22
Contents Owner Installation Important Installation Instructions Page Features Important PRE-ASSEMBLY Check Attaching Motor Power Head Unit to Rail Positioning and Installing Front Wall BracketPositioning the Motor End of Operator Attach Unit to Front Wall BracketMounting Motor End of Opener Installing Wired Wall Station if included Installing LightMounting Door Bracket Installing Deluxe Wireless Wall Station if included Install Entrapment Warning LabelInstall Wireless Infrared Safety Sensor Bracket Install Wireless Infrared Safety SensorInstall Wired Infrared Safety Sensor Wall Mounting Brackets Install Wiring for Wired Infrared Safety Sensor Connecting Wired Infrared Safety Sensor to OpenerMount Wired Infrared Safety Sensors Connecting Electrical PowerWireless Wall Station Security Code Change and Programming Changing Wireless Wall Station CodeAlignment of the Wireless Infrared Safety Sensors Alignment of the Wired Infrared Safety Sensors Transmitter Security Code Change and ProgrammingProgramming Transmitter to Power Head Unit Two Button Transmitter Security Code Change and ProgrammingConnecting Door Arm to Door Setting Trolley Close Posi- tionUpper Door Arm Positioning IMPORTANT! Test Contact Obstruction Sensing Feature Setting Door Opening TravelInfrared Safety Sensor Obstruction Test Programming Wireless Keyless Entry If IncludedInstalling Wireless Keyless Entry If Included Adjustment # 1 Opening and Closing ForceAdjustment # 2 Contact Obstruction Sensing Closing Direction Adjustment # 3 Positive Mechanical Door LockImportant Safety Instructions HOW to Operate the Wireless Keyless Entry if Included Operation of Your OpenerHOW to Operate the Wireless Wall Station If Included Opener Power Head ControlsPage Twice a Year Once a MonthOnce a Year Trouble Shooting Section Parts Breakdown Rail Assembly All Models Description Per Unit # Per Quantum Accessories Limited Lifetime Warranty Cut Template to Aid in Keyless Entry Installation See Step