Remote bus connection unit FAE

1 Connection distributor for 20-m local bus, 6DS9 207-8AA; for commissioning and servicing, can be retrofitted

2 Bus converter 6DS4 400-8AB

3Connector board AF ”Remote bus” 6DS9 203-8CA

4 Power supply module

Fig. 4/14 Remote bus connection unit, redundant design; front door removed

Application

The remote bus connection unit connects desk-top systems, as e. g. the OS 265-3 operation and monitoring system or SICOMP industry-standard PC to a redundant or non-redundant remote bus. Electrical isolation between the local and the remote buses is achieved at the same time. Non-redundant AC 230 V power supply.

Design

The remote bus connection unit consists of a housing for floor or wall mounting, 2 single-height subracks, a mounting rail, mains filter and power supply module for AC 50 Hz 230 V.

It provides space for the 2 bus converters (cf. page 4/9) re- quired to convert the 20-m local bus interface to the remote bus interface. The connector boards AF for converting the cable cross-section (cf. page 4/10) are also fitted into the remote bus connection unit. One connector board is required for each bus converter.

The remote bus connection unit can be fitted with a connection distributor for 20-m local bus for commissioning and servi- cing.This is an open local bus interface for intermediate connec- tion of e. g. a SICOMP industry-standard PC with PROGRAF AS/OS program package for central configuring.

The remote bus connection unit is connected to the interface module for 20-m local bus fitted in the system to be connected via a cable connector.

AF

Connector board ”Remote bus”for converting the cable cross-section

AV

Connection dstributor for 20-m local bus

FS

Front plug for 20-m local bus

SV

Power supply unit of bus converter

UI

Bus interface and inductive coupler of bus converter

Fig. 4/15 Remote bus connection unit, function diagram

Technical data

 

 

 

 

Power supply

AC 50/60 Hz 230 V + 6 %/-10 %

 

Power consumption

Approx. 20 VA

 

 

 

(with 2 bus converters UI)

 

Permissible ambient

 

 

 

 

temperature

0 to + 40 qC

 

 

- Operation

 

 

- Transport and storage

- 40 to + 70 qC

 

 

Degree of protection to

IP 20

 

 

DIN 40 050

 

 

Dimensions (h x d)

500 mm x 236 mm x 313 mm

 

Weight

Approx. 13.5 kg (without bus conver-

 

 

ters and connector boards)

 

 

 

 

 

 

 

 

 

 

 

Ordering data

 

 

 

 

 

 

 

Order No.

 

Remote bus connection unit (basic unit)

 

6DS4 425-8AA

 

with slots for 2 bus converter units Ul

 

 

 

 

 

 

 

Options to be ordered in addition, twice in the

 

 

case of a redundant bus connection:

6DS4 400-8AB

 

Bus converter Ul

 

 

 

Connector board AF ”Remote bus”

6DS9 203-8CA

 

 

 

 

Overvoltage fine protection, can be retrofitted

 

6DS9 210-8AA

 

 

 

 

 

Connection distributor for 20-m local bus

6DS9 207-8AA

 

for commissioning and servicing

 

 

 

 

Cable connector with 1 plug, 0.3 m long

6DS8 201-8MB

 

for connection distributor for 20-m local bus

 

 

 

 

 

 

 

Instructions

 

 

 

 

Remote bus connection unit (FAE)

 

 

Order No.

 

German

 

 

C79000-B8000-C127

 

English

 

 

C79000-B8076-C127

 

French

 

 

C79000-B8077-C127

 

Spanish

 

 

C79000-B8078-C127

 

Bus converter unit, inductive

 

 

 

 

German

 

 

C79000-B8000-C4

 

English

 

 

C79000-B8076-C4

 

French

 

 

C79000-B8077-C4

 

Spanish

 

 

C79000-B8078-C4

 

Siemens PLT 130 . 1994

4/11

Image 28
Contents This catalog is out of date, see note on Teleperm M Summary Siemens PLT 130 This catalog is out of date, see note on Mode of operation Mode of operation Transfer control, data protection and transferData protection Data transferAddressing Addressing, transmission modesTransmission modes Time synchronization Transmission reliabilityConfiguring of communication This catalog is out of date, see note on Design General notes, local range DesignLocal range Remote range Remote range, bus componentsBus components Bus system with linear structure Teleperm M Remote bus Bus components, technical data Technical dataBus configurations Bus configuration, examplesModules and ordering data Interface modules for 20-m local bus N-AS, 8 bit Interface module for 20-m local bus N-BK Interface module for 20-m local bus N-BK 6DS1 223-8ABInterface module for 20-m local bus N16-M, 16 bit Interface module for 20-m local bus N-V.24 DescriptionTechnical data and ordering data Interface module for 20-m local bus N-S5 Description and ordering data Technical data Interface module for 20-m local bus N-ATBus converter unit UI Connector board AF 13 Redundant remote bus with terminating resistorsRemote bus connection unit FAE Remote bus connection subrack S5 18 Bus coupler BK-FF, subrack configuration Bus coupler20 Bus coupler BK-FF, function diagram Cable connectors for 20-m local bus Front plug for 20-m local busApplication and ordering data Front plug with contact points 6DS9 200-8AAOvervoltage protection 23 Coarse overvoltage protection 6DS9 208-8AAConfiguring notes and ordering data Configuring notesRemote bus cable with additional armouring V45466-D21-B65 Remote bus cablesV45466-D21-B55 Connection of remote bus cables Parts kit for splicing coaxial cables S45056-M125-A1C45197-A114-C330 Cable plug SPN684732-00This catalog is out of date, see note on Appendix SY-TRANS 300 CS gateway Description SY-TRANS 300 CS converter German Description VMS/UNIX user interfaceAppendix Documentation for CS 275 bus system Ordering dataSubject index