Siemens CS 275 manual Remote bus connection subrack S5

Page 29

This catalog is out of date, see note on page 2

Remote bus connection subrack S5

Description and ordering data

1Mains terminals AC 230 V

2 Power supply modules

3 Bus converters UI 6DS4 400-8AB

Fig. 4/16 Remote bus connection subrack S5 6DS4 426-8CA

Application

The remote bus connection subrack S5 connects rack-mounted systems, especially SIMATIC S5-155U programmable control- lers, to a redundant or non--redundant remote bus. Electrical isolation between the local and remote buses is achieved at the same time.

Non--redundant or redundant DC 24 V or AC 230 V power sup- ply is possible.

Note: The remote bus connection subrack is not used in the basic cabinets of the AS 235 and AS 235 H automation systems and in the OS 265-3 operation and monitoring system (rack ver- sion) for DC 24 V.

Design

Single-tier 19-inch subrack with 2 slots for bus converter units UI, optionally with power supply module(s).

The power supply in the case of DV 24 V is from the cabinet supply of the programmable controller, in the case of AC 230 V via the power supply module C79451-A3276-A1 (redundant as option).

Technical data

Power supply

DC 24 V (20 to 33 V)

- 6DS4 426-8AA

- 6DS4 426-8BA and

permissible ripple 15 %

 

- 6DS4 426-8CA

AC 50 Hz/60 Hz 230 V + 6 %/ -10 %

Power consumption

Approx. 20 VA

 

with 2 bus converter units

Permissible ambient

 

temperature

0 to + 40 qC

- Operation

- Transport and storage

- 40 to + 70 qC

Degree of protection

IP 00

to DIN 40 050

Protection class

I

(6DS4 426-8BA and

6DS4 426-8CA)

 

Dimensions (h x w x d)

134 mm x 485 mm x 260 mm

Weight

Approx. 4.5 kg

- Subrack (empty)

- Power supply module

Approx. 1.5 kg

- Bus converter unit

Approx. 1.2 kg

 

 

E. g. SIMATIC

S5-155U

Remote bus connection subrack S5

 

Remote bus A

 

Remote bus B

 

 

AF

Connector board ”Remote bus” for converting the cable cross-section

FS

Front plug for 20-m local bus

SV

Power supply unit of bus converter

UI

Bus interface and inductive coupler of bus converter

Fig. 4/17 Remote bus connection subrack S5 6DS4 426-8CA, function diagram

Ordering data

 

 

Order No.

Remote bus connection subrack S5

 

 

with slots for 2 bus converters UI

 

 

¯ For connection to DC 24 V,

 

6DS4 426-8AA

non-redundant or redundant

 

 

¯ With 1 power supply module

 

6DS4 426-8BA

for AC 230 V for non-redundant supply

 

 

to 1 or 2 bus converters UI

 

 

¯ With 2 power supply modules

 

6DS4 426-8CA

for AC 230 V for redundant supply

 

 

to 2 bus converters UI

 

 

The following are required in addition for a

 

 

remote bus connection:

 

 

Bus converter UI

 

6DS4 400-8AB

 

Connector board AF ”Remote bus”

 

6DS9 203-8DA

 

with mounting plate

 

 

Overvoltage fine protection, can be retrofitted

 

6DS9 210-8AA

 

 

 

Instructions

 

 

Remote bus connection subrack S5

 

Order No.

German

 

C79000-B8000-C251

English

 

C79000-B8076-C251

French

 

C79000-B8077-C251

Spanish

 

C79000-B8078-C251

Bus converter, inductive

 

 

German

 

C79000-B8000-C4

English

 

C79000-B8076-C4

French

 

C79000-B8077-C4

Spanish

 

C79000-B8078-C4

4/12

Siemens PLT 130 . 1994

Image 29
Contents This catalog is out of date, see note on Teleperm M Summary Siemens PLT 130 This catalog is out of date, see note on Mode of operation Transfer control, data protection and transfer Mode of operationData protection Data transferTransmission modes Addressing, transmission modesAddressing Transmission reliability Time synchronizationConfiguring of communication This catalog is out of date, see note on Design Local range DesignGeneral notes, local range Bus components Remote range, bus componentsRemote range Bus system with linear structure Teleperm M Remote bus Technical data Bus components, technical dataBus configuration, examples Bus configurationsModules and ordering data Interface modules for 20-m local bus N-AS, 8 bit Interface module for 20-m local bus N-BK 6DS1 223-8AB Interface module for 20-m local bus N-BKInterface module for 20-m local bus N16-M, 16 bit Description Interface module for 20-m local bus N-V.24Technical data and ordering data Interface module for 20-m local bus N-S5 Interface module for 20-m local bus N-AT Description and ordering data Technical dataBus converter unit UI 13 Redundant remote bus with terminating resistors Connector board AFRemote bus connection unit FAE Remote bus connection subrack S5 Bus coupler 18 Bus coupler BK-FF, subrack configuration20 Bus coupler BK-FF, function diagram Front plug for 20-m local bus Cable connectors for 20-m local busApplication and ordering data Front plug with contact points 6DS9 200-8AA23 Coarse overvoltage protection 6DS9 208-8AA Overvoltage protectionConfiguring notes Configuring notes and ordering dataV45466-D21-B55 Remote bus cablesRemote bus cable with additional armouring V45466-D21-B65 Parts kit for splicing coaxial cables S45056-M125-A1 Connection of remote bus cablesC45197-A114-C330 Cable plug SPN684732-00This catalog is out of date, see note on Appendix SY-TRANS 300 CS gateway Description VMS/UNIX user interface Description SY-TRANS 300 CS converter GermanDocumentation for CS 275 bus system Ordering data AppendixSubject index