Heat & Glo LifeStyle COSMO-I30, COSMO-I35 owner manual Models Cosmo-I30 Cosmo-I35

Page 1

Models:

Cosmo-I30

Cosmo-I35

Owner’s Manual

Installation and Operation

NOTICE

DO NOT DISCARD THIS MANUAL

• Important operating

• Read, understand and follow

• Leave this manual with

and maintenance

these instructions for safe

party responsible for use

instructions included.

installation and operation.

and operation.

DO DISCARDNOT

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.

DO NOT store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.

What to do if you smell gas

-DO NOT try to light any appliance.

-DO NOT touch any electrical switch. DO NOT use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppli- er’s instructions.

-If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installation in Mobile Homes, CAN/CSA Z240MH, in Canada.

This appliance is only for use with the type(s) of gas indicated on the rating plate.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter.

A CO detector shall be installed in the room where the appliance in installed.

Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certified or factory trained professionals, or technicians supervised by an NFI certified professional.

Heat & Glo • Cosmo-I30, Cosmo-I352239-900 Rev. H • 1/11

1

Image 1 Contents
What to do if you smell gas Models Cosmo-I30 Cosmo-I35Homeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyIPI Battery Tray/Battery Installation Clear SpaceControl Module Operation Module ResetBefore Lighting Fireplace Final inspection by Lighting Instructions IPIAfter Appliance is Lit Frequently Asked QuestionsMaintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianVenting FireboxIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsSide View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsPlacing, Securing and Leveling the Appli- ance Location of AUX300 for Remote Control Blower FunctionMasonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversion Gas InformationGas Pressure Gas ConnectionIntelliFire Plus Ignition System Wiring Wiring RequirementsON/OFF Switch Electrical InformationBRN To Valve Bracket BLK Ground RE D Optional Accessories RequirementsSee .H for control module operation instructions Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Air Shutter Settings Air Shutter SettingSymptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System To remove any contaminants that may have accumulated on flame Reference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsPart number list on following Service PartsModern Metal Insert, IPI At Depot Service Parts ListCOSMO-I35 Stocked COSMO-I35COSMO-I30, COSMO-I35 Contact Information