Heat & Glo LifeStyle COSMO-I30 Electrical Information, Wiring Requirements, Code CSA C22.1

Page 25

10 Electrical Information

A. Wiring Requirements

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.

This appliance comes standard with a 120 VAC cord assembly which has a female plug in to accommodate all control options and accessories. See Figure 10.1. This is required for proper operation of the appliance (IntelliFire Ignition). An outlet box may be installed in a bottom back corner of the existing solid fuel masonry or factory built fireplace to plug in the cord assembly, or the supplied power cord may be routed out onto the hearth to a nearby outlet.

A 120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Low voltage and 120 VAC voltage cannot be shared within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire 120V to the valve or to the appliance wall switch. Incor- rect wiring will damage controls.

An IntelliFire Plus™ ignition system is standard with this appliance.

B. IntelliFire Plus™ Ignition System Wiring

Wire an outlet box (120VAC) in the bottom back corner of the existing solid fuel masonry or factory built fireplace to plug in the cord assembly. The supplied cord assembly may also be routed out onto the hearth to a nearby outlet.

WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.

Refer to Figure 10.1, IPI Wiring Diagram.

This appliance is equipped with an IntelliFire Plus™ control valve which operates on a 6 volt/1.5 AMP system.

Plug the 6 volt transformer plug into the cord assembly to supply power to the insert OR install 4 AA cell batteries (not included) into the battery pack before use.

ON/OFF Switch

An ON/OFF switch is included with the appliance surround and should be attached to surround/facing. (See Installation instructions for remote control/fronts).

If desired an additional wall switch or thermostat may be added to system as shown in Figure 10.1.

 

 

INTERMITTENT

 

 

 

 

 

 

PILOT IGNITOR

 

 

 

 

 

 

 

 

RC100

RC200

RC300

TO CORD ASSEMBLY

 

 

 

(OPTIONAL WALL CONTROLS)

120VAC

 

MODULE

 

 

 

 

 

 

 

 

 

AUX2 NOT USED FOR INSERT MODELS.

 

 

ORG

 

AUX300 MODULE

 

 

 

 

 

PROTECTIVE COVER INCLUDED

 

 

WHT

 

 

 

FLAME

 

FAN

 

TO CORD

 

 

 

AUX1 AUX2

 

MODULATION

 

 

 

 

 

 

ASSEMBLY

 

 

 

 

 

 

 

 

 

 

 

 

(110V)

 

 

 

 

BATTERY PACK

 

 

 

 

RED

6V DC

 

 

ORANGE

GREEN

RED

BLK

 

 

ROCKER

(PILOT)

(MAIN)

BLK

 

 

 

SWITCH

 

 

BROWN

 

 

 

 

 

 

 

WALL SWITCH

 

 

 

 

 

OR REMOTE

 

 

 

 

GROUND

INSTALL

 

 

Figure 10.1 IPI Wiring Diagram

Heat & Glo • Cosmo-I30, Cosmo-I352239-900 Rev. H • 1/11

25

Image 25 Contents
What to do if you smell gas Models Cosmo-I30 Cosmo-I35Homeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyIPI Battery Tray/Battery Installation Clear SpaceControl Module Operation Module ResetBefore Lighting Fireplace Final inspection by Lighting Instructions IPIAfter Appliance is Lit Frequently Asked QuestionsMaintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianVenting FireboxIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsSide View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsPlacing, Securing and Leveling the Appli- ance Location of AUX300 for Remote Control Blower FunctionMasonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversion Gas InformationGas Pressure Gas ConnectionIntelliFire Plus Ignition System Wiring Wiring RequirementsON/OFF Switch Electrical InformationBRN To Valve Bracket BLK Ground RE D Optional Accessories RequirementsSee .H for control module operation instructions Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Air Shutter Settings Air Shutter SettingSymptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System To remove any contaminants that may have accumulated on flame Reference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsPart number list on following Service PartsModern Metal Insert, IPI At Depot Service Parts ListCOSMO-I35 Stocked COSMO-I35COSMO-I30, COSMO-I35 Contact Information