Heat & Glo LifeStyle COSMO-I35, COSMO-I30 Placing, Securing and Leveling the Appli- ance

Page 22

CUT AND BEND

FLASHING AS NEEDED

TO FIT CHIMNEY

SEALANT

ADHESIVE

Figure 8.2

Trim chimney top plate to minimize excess overhang or bend over flue tile (see Figure 8.2).

Place 3/8 inch bead of 300º F silicone on flue tile top.

D.Placing, Securing and Leveling the Appli- ance

Install insert (without surround attached) into existing fireplace while pulling collar slide plate forward.

Install gas line into hole provided on insert side.

If applicable install remote control wires into insert side (see Section 8.E).

Secure collar slide plate to appliance by placing locking handle into position with locking tabs (see Figure 8.1) and secure with #8 screw.

Level the appliance from side to side and front to back. If necessary, use the leveling legs included with the manual bag to set each corner of the base.

Position any excess flexible vent pipe back up into chimney without sagging. Twist and push flex vent together to shorten.

Install fiberglass insulation pieces to back face of surround.

Attach surround. Follow instructions for surround installation included with the front.

Push insert into the opening so that it tightly overlaps the fireplace opening.

WARNING! Risk of Fire! Only an approved Hearth & Home Technologies surround may be used to cover inte- gral grills on solid fuel burning fireplaces. No other com- ponents such as shrouds, sheetmetal plates, etc., may be used to seal off vents.

WARNING! Risk of Explosion! Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

WARNING! Risk of Explosion/Combustion Fumes! Connect vent sections per installation instructions.

Connect exhaust vent pipe ONLY to exhaust starting collar and termination cap center collar.

Connect inlet air vent ONLY to inlet air collar on appliance and the termination cap inlet air collar.

DO NOT allow vent to sag below connection point to appliance.

E. Remote Control

If a remote control kit is used to control blower function, the Auxiliary 300 module can only be placed in the control cavity to the right of the control panel. See Figure 8.3.

AUXILIARY 300 MODULE

Figure 8.3 Location of AUX300 for Remote Control Blower Function

22

Heat & Glo • Cosmo-I30, Cosmo-I352239-900 Rev. H • 1/11

Image 22 Contents
Models Cosmo-I30 Cosmo-I35 What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceControl Module Operation Module ResetBefore Lighting Fireplace Lighting Instructions IPI Final inspection byFrequently Asked Questions After Appliance is LitGlass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection FireboxBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningMantel and Wall Projections Side ViewTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsLocation of AUX300 for Remote Control Blower Function Placing, Securing and Leveling the Appli- anceFactory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalGas Pressure Gas InformationFuel Conversion Gas ConnectionON/OFF Switch Wiring RequirementsIntelliFire Plus Ignition System Wiring Electrical InformationOptional Accessories Requirements BRN To Valve Bracket BLK Ground RE DFan Wiring with Remote See .H for control module operation instructionsFinishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup Air Shutter Setting Air Shutter SettingsSymptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System To remove any contaminants that may have accumulated on flame Appliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsPart number list on following Service PartsModern Metal Insert, IPI Service Parts List At DepotCOSMO-I35 COSMO-I35 StockedCOSMO-I30, COSMO-I35 Contact Information