Energy Tech Laboratories 40 Series, F3, CL Series, F5 manual Connect Field Wiring

Page 12

Figure 10: Recommended Piping for Combination

Heating & Cooling (Refrigeration) Systems

in left rear corner on top of boiler as shown in Figure 1C. Tighten with wrench. Pipe discharge as shown in Figure 11. Installation of the relief valve must be consistent with ANSI/ASME Boiler and Pressure Vessel Code, Section IV.

2.Install ¾" drain valve in wet return piping as shown in Figure 11.

3.On boilers with rear tankless heater, factory wired L4006A Aquastat Heater Control was not installed in heater. Locate ¾" NPT Immersion Well, apply sealant and thread into ¾" NPT tapping on heater. Apply heat transfer paste (not furnished) to control bulb and insert bulb into immersion well. Tighten clamping screws to secure control to immersion well. Secure 18/2 Control Cable Wire to jacket right side panel with 5/16" cable clamp provided, refer to Figure 1C.

4.CONNECT FIELD WIRING

a.Connect the field wiring to the pressure limit, the R8239C Control Center, the LWCO and the burner primary control. If equipped with tankless heater, connect field wiring from the aquastat control to the R8239C Control Center's "R-G" terminals. Make the wiring connections as shown in Figure 19B.

H.CONNECT SUPPLY AND RETURN PIPING TO HEATING SYSTEM.

1.CLEARANCES — Steam and hot water pipes shall have clearances of at least ½” from all combustible construction.

Figure 11: Recommended Boiler Piping For Gravity Return Steam Boiler

12

Image 12
Contents Price $3.00 Important Information Please Read this page Carefully Page Table of Contents General InformationCL3 Thru CL5 Water Boiler Less Tankless Heater Boiler Dimensions Minimum Chimney Size Approx. Water Rating data II. Installation Instructions Remove CrateRemoval of Boiler from Skid Inspect Combustion Target Wall and Combustion Chamber LinerInstallation/Removal of Drawer Assembly Electrode Setting Recommended Boiler Piping for Series Loop Hot Water System Connect Field Wiring Connect Supply and Return Piping to Heating SystemWater Boiler Steam BoilerOxygen Contamination Schematic Tankless Heater Piping Tankless Heater Data Recommended Smokepipe Arrangement Chimney Requirements Fuel Units and OIL Lines Single stage units 3450 rpm two pipe systemsSequence of Operation Wiring Diagram, Water without Tankless Heater, Riello Burner Sequence of Operation Page Sequence of Operation Page III. Indirect Water Heater Piping Indirect Water Heater Piping on CL Series Water BoilerIV. Operating and Service Instructions LubricationDisplay Readout LEd error codes OperationRemove GUN Assembly High Limit ControllerLOW Limit and Circulator Controller Adjust OIL Burner Before Starting Open ALL OIL Line ValvesStart OIL Burner Adjust OIL Burner While Operating CAD Cell Location and ServiceCheck for Clean CUT OFF of Burner Flame FailureCheckout Procedure Test ControlsPrimary Relay Test Remove JumperMaintenance and Service Instructions Water Boilers Excessive MAKE-UP Water Hints on CombustionSuction Line Leaks High Altitude Installations VI. Boiler Cleaning Clean TOP of Boiler SectionsClean the Firebox Reassemble BoilerAvoid Breathing Fiber Particulates and Dust Trouble Shooting Carlin 40200 Oil Primary Control Carlin 40200 OIL Primary ControlVII. Repair Parts Bare Boiler Assembly Exploded View Boiler Assembly Jacket Assembly Exploded View CL3 Thru CL5 Water Boilers Trim and Controls CL3 Thru CL5 Steam Boilers Trim and Controls Beckett OIL Burner Parts List Beckett OIL Burner Part NOS. for CL Series Boilers VIII. Low Water Cut Off Lwco WhenBeckett AFG Riello OIL Burner Part Numbers for CL Series BOILERS  Service Record Service Record Service Record Page Limited Warranties

F3, F5, 40 Series, CL Series specifications

Energy Tech Laboratories has made significant strides in innovation and sustainability with its well-regarded CL Series, 40 Series, F5, and F3 product lines. Each series is designed to provide scalable energy solutions tailored to meet diverse industry demands while promoting efficiency and environmental responsibility.

The CL Series stands out for its compact design and modular construction. It is ideal for small to medium-sized enterprises looking to optimize energy consumption. One of the primary features of the CL Series is its advanced energy management system, which uses real-time data analytics to help users monitor and analyze their energy usage patterns. Additionally, it is equipped with a regenerative braking technology that captures and reuses energy, making it exceptionally efficient.

In contrast, the 40 Series is targeted towards larger industrial applications. This series boasts high-capacity energy storage solutions and integrates seamlessly with existing systems. One of its most remarkable features is its adaptive load management system, which intelligently distributes power based on real-time demand, ensuring maximum efficiency and minimal waste. The 40 Series is also built with robust safety protocols, including fire suppression systems and advanced fault detection technologies.

The F5 model is engineered for ultimate performance. It incorporates cutting-edge battery technology that enhances energy density, resulting in longer operational life and reduced maintenance costs. Its real-time monitoring capabilities offer users the ability to track performance metrics from anywhere, further enabling proactive decision-making. Additionally, the F5 features a modular battery design, allowing for easy upgrades and expansions as energy needs grow.

Finally, the F3 series exemplifies the future of energy technology with its innovative approach to renewable energy integration. The F3 is designed to work with solar and wind energy systems, leveraging advanced algorithms to maximize energy capture from these sources. Users benefit from its intelligent grid interface, which allows for efficient energy distribution within microgrid configurations.

In summary, Energy Tech Laboratories’ CL Series, 40 Series, F5, and F3 combine robust engineering and innovative technologies to address the varying energy needs of users. With features like real-time monitoring, adaptive load management, and renewable energy integration, these product lines not only enhance operational efficiency but also contribute to a sustainable energy future. As industries increasingly look towards improving energy practices, these series stand out as relevant, viable solutions in the evolving landscape of energy technology.