Energy Tech Laboratories F5, 40 Series Recommended Boiler Piping for Series Loop Hot Water System

Page 11

Figure 9: Recommended Boiler Piping for Series Loop Hot Water System

NOTE: Vertical piping will prevent door from opening fully for service and cleaning of boiler.

2.Thread relief valve onto factory installed ¾" NPT x 7¼" nipple located in left rear corner on top

of boiler as shown in Figures 1A and 1B. Valve spindle must be in vertical position. Tighten with wrench. Pipe discharge as shown in Figure 9. Installation of the relief valve must be consistent with ANSI/ASME Boiler and Pressure Vessel Code, Section IV.

3.On boilers with rear tankless heater, factory wired L7224C Control Relay was not installed in heater. Locate ¾" NPT Immersion Well, apply sealant and thread into ¾" NPT tapping on heater. Apply heat transfer paste (not furnished) to control bulb and insert bulb into immersion well. Tighten clamp screws to secure control to immersion well. Secure

control conduit to jacket right side panel with 5/8" cable clamp provided, refer to Figure 1B.

4.Connect Field Wiring

a.Water boilers without tankless heater and with front tankless heater. Connect the field wiring from the circulator to the aquastat control and from the control to the burner. Make the wiring connections as shown on Figures 16B.

b.Water boilers with rear tankless heater. Connect the field wiring from a standard junction box to the circulator, aquastat control and burner. Make the wiring connections as shown on Figure 17B.

G.INSTALL STEAM BOILER TRIM AND CONTROLS, (see Figures 1C and 1D).

1.Thread ¾" MPT safety valve and ¾" NPT coupling onto factory installed ¾" NPT x 7¼" nipple located

11

Image 11
Contents Price $3.00 Important Information Please Read this page Carefully Page General Information Table of ContentsCL3 Thru CL5 Water Boiler Less Tankless Heater Boiler Dimensions Minimum Chimney Size Approx. Water Rating data Inspect Combustion Target Wall and Combustion Chamber Liner II. Installation InstructionsRemove Crate Removal of Boiler from SkidInstallation/Removal of Drawer Assembly Electrode Setting Recommended Boiler Piping for Series Loop Hot Water System Connect Supply and Return Piping to Heating System Connect Field WiringOxygen Contamination Water BoilerSteam Boiler Schematic Tankless Heater Piping Tankless Heater Data Recommended Smokepipe Arrangement Chimney Requirements Single stage units 3450 rpm two pipe systems Fuel Units and OIL LinesSequence of Operation Wiring Diagram, Water without Tankless Heater, Riello Burner Sequence of Operation Page Sequence of Operation Page Indirect Water Heater Piping on CL Series Water Boiler III. Indirect Water Heater PipingDisplay Readout IV. Operating and Service InstructionsLubrication Operation LEd error codesLOW Limit and Circulator Controller Remove GUN AssemblyHigh Limit Controller Start OIL Burner Adjust OIL Burner Before StartingOpen ALL OIL Line Valves Flame Failure Adjust OIL Burner While OperatingCAD Cell Location and Service Check for Clean CUT OFF of BurnerRemove Jumper Checkout ProcedureTest Controls Primary Relay TestMaintenance and Service Instructions Water Boilers Suction Line Leaks Excessive MAKE-UP WaterHints on Combustion High Altitude Installations Reassemble Boiler VI. Boiler CleaningClean TOP of Boiler Sections Clean the FireboxAvoid Breathing Fiber Particulates and Dust Carlin 40200 OIL Primary Control Trouble Shooting Carlin 40200 Oil Primary ControlVII. Repair Parts Bare Boiler Assembly Exploded View Boiler Assembly Jacket Assembly Exploded View CL3 Thru CL5 Water Boilers Trim and Controls CL3 Thru CL5 Steam Boilers Trim and Controls Beckett OIL Burner Parts List Beckett OIL Burner Part NOS. for CL Series Boilers When VIII. Low Water Cut Off LwcoBeckett AFG Riello OIL Burner Part Numbers for CL Series BOILERS  Service Record Service Record Service Record Page Limited Warranties

F3, F5, 40 Series, CL Series specifications

Energy Tech Laboratories has made significant strides in innovation and sustainability with its well-regarded CL Series, 40 Series, F5, and F3 product lines. Each series is designed to provide scalable energy solutions tailored to meet diverse industry demands while promoting efficiency and environmental responsibility.

The CL Series stands out for its compact design and modular construction. It is ideal for small to medium-sized enterprises looking to optimize energy consumption. One of the primary features of the CL Series is its advanced energy management system, which uses real-time data analytics to help users monitor and analyze their energy usage patterns. Additionally, it is equipped with a regenerative braking technology that captures and reuses energy, making it exceptionally efficient.

In contrast, the 40 Series is targeted towards larger industrial applications. This series boasts high-capacity energy storage solutions and integrates seamlessly with existing systems. One of its most remarkable features is its adaptive load management system, which intelligently distributes power based on real-time demand, ensuring maximum efficiency and minimal waste. The 40 Series is also built with robust safety protocols, including fire suppression systems and advanced fault detection technologies.

The F5 model is engineered for ultimate performance. It incorporates cutting-edge battery technology that enhances energy density, resulting in longer operational life and reduced maintenance costs. Its real-time monitoring capabilities offer users the ability to track performance metrics from anywhere, further enabling proactive decision-making. Additionally, the F5 features a modular battery design, allowing for easy upgrades and expansions as energy needs grow.

Finally, the F3 series exemplifies the future of energy technology with its innovative approach to renewable energy integration. The F3 is designed to work with solar and wind energy systems, leveraging advanced algorithms to maximize energy capture from these sources. Users benefit from its intelligent grid interface, which allows for efficient energy distribution within microgrid configurations.

In summary, Energy Tech Laboratories’ CL Series, 40 Series, F5, and F3 combine robust engineering and innovative technologies to address the varying energy needs of users. With features like real-time monitoring, adaptive load management, and renewable energy integration, these product lines not only enhance operational efficiency but also contribute to a sustainable energy future. As industries increasingly look towards improving energy practices, these series stand out as relevant, viable solutions in the evolving landscape of energy technology.