Energy Tech Laboratories F5, 40 Series, F3, CL Series manual Rating data

Page 7

table 2: rating data

 

Burner

DOE Heating

I=B=R NET Ratings

Minimum Chimney

AFUE %

Boiler Model

Capacity

Capacity

 

Requirements

 

 

 

 

 

 

 

 

No. *

GPH

MBH

Water

Steam

Water

Steam

Steam

Round

Rectangle

 

Height

Water

Steam

 

 

 

 

 

MBH

MBH

MBH

MBH

Sq. Ft.

In. Dia.

In. x In.

 

Ft.

 

 

CL3-091(W)

0.65

91

80

---

70

---

---

6

8 x 8

 

15

86.0

---

CL3-091(S)

0.65

91

---

78

---

56

233

6

8 x 8

 

15

---

84.1

CL3-105(W)

0.75

105

91

---

79

---

---

6

8 x 8

 

15

85.1

---

CL3-105(S)

0.75

105

---

90

---

68

283

6

8 x 8

 

15

---

83.8

CL3-140(W)

1.00

140

120

---

104

---

---

6

8 x 8

 

15

83.6

---

CL3-140(S)

1.00

140

---

119

---

89

370

6

8 x 8

 

15

---

82.7

CL4-126(W)

0.90

126

111

---

97

---

---

7

8 x 8

 

15

85.8

---

CL4-126(S)

0.90

126

---

108

---

81

338

7

8 x 8

 

15

---

84.1

CL4-175(W)

1.25

175

152

---

132

---

---

7

8 x 8

 

15

84.2

---

CL4-175(S)

1.25

175

---

149

---

112

467

7

8 x 8

 

15

---

83.5

CL4-210(W)

1.50

210

179

---

156

---

---

7

8 x 8

 

15

83.1

---

CL4-210(S)

1.50

210

---

177

---

133

554

7

8 x 8

 

15

---

82.6

CL5-168(W)

1.20

168

147

---

128

---

---

8

8 x 8

 

15

85.7

---

CL5-168(S)

1.20

168

---

144

---

108

450

8

8 x 8

 

15

---

83.7

CL5-245(W)

1.75

245

210

---

183

---

---

8

8 x 8

 

15

83.0

---

CL5-245(S)

1.75

245

---

207

---

155

646

8

8 x 8

 

15

---

82.5

CL5-280(W)

2.00

280

238

---

207

---

---

8

8 x 8

 

15

82.5

---

CL5-280(S)

2.00

280

---

235

---

176

733

8

8 x 8

 

15

---

82.3

* Boiler Model Suffix: (W) = Water, (S) = Steam

Figure 2: Minimum Installation Clearances To Combustible Materials (Inches)

 

 

C

 

 

A

B

Chimney

D

E

Above

Front

Connector

Rear

Sides

6

24

18

6

6

NOTE 1: Listed clearances comply with American National Standard NFPA 31, Standard for the Installation of Oil Burn- ing Equipment.

NOTE 2: CL Series boilers can be installed in rooms with clearances from combustible material as listed above. Listed clearances cannot be reduced for alcove or closet installa- tions.

NOTE 3: For reduced clearances to combustible material, protection must be provided as described in the ANSI/NFPA 31 standard.

Image 7
Contents Price $3.00 Important Information Please Read this page Carefully Page General Information Table of ContentsCL3 Thru CL5 Water Boiler Less Tankless Heater Boiler Dimensions Minimum Chimney Size Approx. Water Rating data Inspect Combustion Target Wall and Combustion Chamber Liner II. Installation InstructionsRemove Crate Removal of Boiler from SkidInstallation/Removal of Drawer Assembly Electrode Setting Recommended Boiler Piping for Series Loop Hot Water System Connect Supply and Return Piping to Heating System Connect Field WiringSteam Boiler Water BoilerOxygen Contamination Schematic Tankless Heater Piping Tankless Heater Data Recommended Smokepipe Arrangement Chimney Requirements Single stage units 3450 rpm two pipe systems Fuel Units and OIL LinesSequence of Operation Wiring Diagram, Water without Tankless Heater, Riello Burner Sequence of Operation Page Sequence of Operation Page Indirect Water Heater Piping on CL Series Water Boiler III. Indirect Water Heater PipingLubrication IV. Operating and Service InstructionsDisplay Readout Operation LEd error codesHigh Limit Controller Remove GUN AssemblyLOW Limit and Circulator Controller Open ALL OIL Line Valves Adjust OIL Burner Before StartingStart OIL Burner Flame Failure Adjust OIL Burner While OperatingCAD Cell Location and Service Check for Clean CUT OFF of BurnerRemove Jumper Checkout ProcedureTest Controls Primary Relay TestMaintenance and Service Instructions Water Boilers Hints on Combustion Excessive MAKE-UP WaterSuction Line Leaks High Altitude Installations Reassemble Boiler VI. Boiler CleaningClean TOP of Boiler Sections Clean the FireboxAvoid Breathing Fiber Particulates and Dust Carlin 40200 OIL Primary Control Trouble Shooting Carlin 40200 Oil Primary ControlVII. Repair Parts Bare Boiler Assembly Exploded View Boiler Assembly Jacket Assembly Exploded View CL3 Thru CL5 Water Boilers Trim and Controls CL3 Thru CL5 Steam Boilers Trim and Controls Beckett OIL Burner Parts List Beckett OIL Burner Part NOS. for CL Series Boilers When VIII. Low Water Cut Off LwcoBeckett AFG Riello OIL Burner Part Numbers for CL Series BOILERS  Service Record Service Record Service Record Page Limited Warranties

F3, F5, 40 Series, CL Series specifications

Energy Tech Laboratories has made significant strides in innovation and sustainability with its well-regarded CL Series, 40 Series, F5, and F3 product lines. Each series is designed to provide scalable energy solutions tailored to meet diverse industry demands while promoting efficiency and environmental responsibility.

The CL Series stands out for its compact design and modular construction. It is ideal for small to medium-sized enterprises looking to optimize energy consumption. One of the primary features of the CL Series is its advanced energy management system, which uses real-time data analytics to help users monitor and analyze their energy usage patterns. Additionally, it is equipped with a regenerative braking technology that captures and reuses energy, making it exceptionally efficient.

In contrast, the 40 Series is targeted towards larger industrial applications. This series boasts high-capacity energy storage solutions and integrates seamlessly with existing systems. One of its most remarkable features is its adaptive load management system, which intelligently distributes power based on real-time demand, ensuring maximum efficiency and minimal waste. The 40 Series is also built with robust safety protocols, including fire suppression systems and advanced fault detection technologies.

The F5 model is engineered for ultimate performance. It incorporates cutting-edge battery technology that enhances energy density, resulting in longer operational life and reduced maintenance costs. Its real-time monitoring capabilities offer users the ability to track performance metrics from anywhere, further enabling proactive decision-making. Additionally, the F5 features a modular battery design, allowing for easy upgrades and expansions as energy needs grow.

Finally, the F3 series exemplifies the future of energy technology with its innovative approach to renewable energy integration. The F3 is designed to work with solar and wind energy systems, leveraging advanced algorithms to maximize energy capture from these sources. Users benefit from its intelligent grid interface, which allows for efficient energy distribution within microgrid configurations.

In summary, Energy Tech Laboratories’ CL Series, 40 Series, F5, and F3 combine robust engineering and innovative technologies to address the varying energy needs of users. With features like real-time monitoring, adaptive load management, and renewable energy integration, these product lines not only enhance operational efficiency but also contribute to a sustainable energy future. As industries increasingly look towards improving energy practices, these series stand out as relevant, viable solutions in the evolving landscape of energy technology.