Century Jefferson manual Attach the Inner Vent Assembly to the stove

Page 16

Jefferson Direct Vent/Natural Vent Gas Heater

First Section of

Vent Pipe

4” Inner

Starter

Pipe

1/4”-20 x 1/2” Phillips Screw

CEMENT

ST211

Fig. 17 Connect the inner starter with the next section of inner vent pipe.

4.Attach the Inner Vent Assembly to the stove.

• Run a bead of sealant around the bottom end of the starter pipe and attach the assembly to the stove using three 1/4-20 x 3/8” Phillips screws provided in the parts bag. (Fig. 18)

CEMENT

ST212

Fig. 18 Attach inner assembly to flue collar.

5.Install the Outer Adapter Pipe. Insert the pipe over the stove flue collar, keeping the vertical seam oriented to the back of the stove. Also, be sure to align holes on the pipe with the holes on the flue collar of the firebox. Fasten the pipe to the holes in the flue collar with the #12 x 1/2” sheet metal screws provided. (Fig. 19)

ST213

Fig. 19 Fasten outer pipe with #12 x 1/2” sheet metal screws.

Install the Vent Adapter Pipe

(Simpson Dura-Vent Components)

1.Install the Restrictor Plate. Consult the “Vertical Terminations” on Page 9 to determine whether the restrictor plate is needed. If so, put the restrictor plate in place within the inner flue collar as shown in Figure 16.

2.Discard the inner starter pipe shipped with the log- set. Using the starter pipe assembly listed on Page 13, slide the inner section out to allow access.

• Run a bead of sealant around the bottom end of the starter pipe and attach the assembly to the stove using three 1/4-20 x 3/8” Phillips screws provided in the parts bag. (Fig. 20)

3.Install the Outer Adapter Pipe. Apply a 1/4” bead of cement around the outside surface, about one inch from the crimped end. (Fig. 21) Orient the verti- cal seam to the rear, and insert the crimped end of the outer pipe into the flue collar. Fasten with three

(3) sheet metal screws provided.

1/4-20 x

Inner Adapter Pipe

 

3/8” Phillips

 

Screws

 

 

CEMENT

ST355

Fig. 20 Simpson Dura-Vent - install inner adapter pipe.

1616

30004177

Image 16
Contents Jefferson Direct Vent/Natural Vent Gas Heater Table of Contents Installation & Operating Instructions Requirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedJefferson Direct Vent/Natural Vent Stove Dimensions Jefferson dimensionsLocating The Stove Installation RequirementsClearance Requirements Wall and Ceiling Clearances Wall Centerline from FloorHearth Requirements Gas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal Termination Direct Vent onlyVertical Termination Direct Vent only Restictor Plate is used on Direct Vent installations onlyVent Termination Clearances Location of Vent Termination Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesVenting Requirements and Options Direct Vent only Approved Vent System ComponentsAssembly Procedures Install the Optional FanTools Required Unpack the StoveInstall the Vent Adapter Pipe Venting System Assembly Direct Vent General InformationFor Canadian installations The venting system must Attach the Inner Vent Assembly to the stove Attach inner assembly to flue collarSide Wall Termination Assembly Simpson Dura-Vent install outer adapter pipeVent Termination Below Grade Measure the horizontal lengthVertical Through the Roof Vent Assembly Venting System Assembly Natural Vent General InformationInstall the Vent Pipe Install the Log Set Air Shutter Adjustment Air Shutter Adjustment InstructionsAir Shutter Adjustment Connect the Gas Supply LineRemove stove front Complete the Assembly Install ON/OFF SwitchInstall the Stove Front Thermostat Connection optionalFlame & Temperature Adjustment Flame CharacteristicsOperation Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionConversion Precautions Conversion ProcedureFuel Conversion Instructions Pilot TypeInjector Orifice Size Matrix Conversion to LP Input BTU/hMaintenance Gasket Replacement Stove DisassemblyInspect the Vent System Annually Check the Gas Flame RegularlyWiring Diagrams BLKJefferson Direct Vent/Natural Vent Gas Heater DescriptionDescripción Fuel Conversion KitsOptional Accessories Remote ControlsFan Kits Decorative Rings3636 Jefferson Direct Vent /Natural Vent Gas Heater 3838 CFM Corporation Toll Free Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %