Century Jefferson manual Wiring Diagrams, Blk

Page 32

Jefferson Direct Vent/Natural Vent Gas Heater

Wiring Diagrams

OFF ON

On/Off Switch

Wiring

POWER

CORD

FAN

Black

TP/TH

TP

TH

opile Therm

Black

ST124b

WHT BLK

BLK

Chassis

GRN

 

 

Ground

 

 

 

 

 

K

 

 

L

 

 

B

 

BLK

 

 

 

 

Thermostat

Optional Thermostat

(Optional)

Wiring

 

FAN JUNCTION BOX

Black

TP/TH

TP

TH

opile Therm

Black

ST124c

Strain Relief

ON / OFF

Rheostat

Snapstat

WHT

Fig. 62 On/off switch and optional thermostat circuit.

NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP- PLIED WITH THE APPLIANCE, MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE SF-2, 200°C WIRE OR ITS EQUIVALENT.

Drafthood Adapter

Harness

Remote Wall Switch or

ON/OFF Rocker Switch

 

TH

 

 

TP

Gas

 

Valve

 

 

 

TH

 

ST943

TP

 

Fig. 63 Draft Hood Adapter (FSDHAG) wiring. Used on

RN/RP models only.

 

K

 

L

BLK

B

 

 

 

GRN

Chassis Ground

RHEOSTAT / SNAPSTAT

 

 

BOX

ST153

MOTOR

Schematic Diagram

 

BLK

BLK

BLK

 

 

 

BLK

SNAPSTAT

WHT

WHT

GRN

RHEOSTAT

 

 

ON/OFF

ST236

Fig. 64 Fan circuit.

3232

30004177

Image 32
Contents Jefferson Direct Vent/Natural Vent Gas Heater Table of Contents Installation & Operating Instructions Requirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedJefferson Direct Vent/Natural Vent Stove Dimensions Jefferson dimensionsClearance Requirements Installation RequirementsLocating The Stove Hearth Requirements Wall Centerline from FloorWall and Ceiling Clearances Gas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal Termination Direct Vent onlyVent Termination Clearances Restictor Plate is used on Direct Vent installations onlyVertical Termination Direct Vent only Location of Vent Termination Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesVenting Requirements and Options Direct Vent only Approved Vent System ComponentsAssembly Procedures Install the Optional FanTools Required Unpack the StoveFor Canadian installations The venting system must Venting System Assembly Direct Vent General InformationInstall the Vent Adapter Pipe Attach the Inner Vent Assembly to the stove Attach inner assembly to flue collarSide Wall Termination Assembly Simpson Dura-Vent install outer adapter pipeVent Termination Below Grade Measure the horizontal lengthVertical Through the Roof Vent Assembly Venting System Assembly Natural Vent General InformationInstall the Vent Pipe Install the Log Set Air Shutter Adjustment Air Shutter Adjustment InstructionsAir Shutter Adjustment Connect the Gas Supply LineRemove stove front Complete the Assembly Install ON/OFF SwitchInstall the Stove Front Thermostat Connection optionalFlame & Temperature Adjustment Flame CharacteristicsOperation Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionConversion Precautions Conversion ProcedureFuel Conversion Instructions Pilot TypeInjector Orifice Size Matrix Conversion to LP Input BTU/hMaintenance Gasket Replacement Stove DisassemblyInspect the Vent System Annually Check the Gas Flame RegularlyWiring Diagrams BLKJefferson Direct Vent/Natural Vent Gas Heater DescriptionDescripción Fuel Conversion KitsOptional Accessories Remote ControlsFan Kits Decorative Rings3636 Jefferson Direct Vent /Natural Vent Gas Heater 3838 CFM Corporation Toll Free Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %