Fuel Conversion Instructions

WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruc- tions is not followed exactly, a fire, explosion

or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is respon- sible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before pro- ceeding with the conversion.

Cap

H

Lift Open

HI

 

I

 

LO

 

LO

Hi/Lo

 

 

Knob

Center Screw

CO100

Fig. 52 Remove center screw from Hi-Lo knob.

7.Insert blue painted screw when converting to natural gas and red painted screw when converting to LP.

8.Tighten screw, replace cap.

9.Remove the rear log bracket by removing the screw. (fig. 53)

10.Remvoe the right and left log bracket assembly by removing the two screws which hold the burner in place. (Fig. 53)

11.Hold the burner at the right hand side and lidft to clear the right burner leg. Then pull to the right to clear the injectors on the left hand side.

12. Locate pilot. (Fig. 53)

 

���

��

 

��������

Gas Supply Inlet

Main

Gas Line

ST226

13. Replace pilot orifice.

 

Remove Screws

Rear Log Bracket

 

 

Pilot

Fig. 51 Attach the gas line to the left side of the valve.

Conversion Precautions

Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.

Conversion Procedure

1.Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 30, Fig. 59)

2.Swing open the swiveling latches at the top left and right corners of the glass frame. (Page 31, Fig. 60)

3.Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a coun- ter protected by a towel.

4.Remove the logset from the firebox.

5.Remove cap from HI/Lo knob. This can be accom- plished by lifting the plastic cap off the screws. (Fig. 52)

6.Remove the screw from center of Hi/Lo knob with small screwdriver turnign counterclockwise. (Fig. 52)

Left & Right Log

ST350

Bracket Assembly

Fig. 53 Remove rear log bracket and left and right log bracket assembly.

Pilot Type 1

Remove pilothood by lifitng up. (Fig. 54) NOTE: Do not remove snap ring to remove pilot hood. NOTE: It is not necessary to remove the pilot tube for conversion.

Remove pilot orifice with allen wrench. (Fig. 55)

Install the conversion orifice.

Reinstall pilot hood. Be sure to align hood with index tab.

Pilot Type 2

Loosen pilot hood by turning counterclockwise using a 7/16” wrench. (Fig. 56) NOTE: You may use penetrating oit to prevent pilot hood threads

from seizing up.

2828

30004177

Image 28
Contents Jefferson Direct Vent/Natural Vent Gas Heater Table of Contents Installation & Operating Instructions Requirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedJefferson Direct Vent/Natural Vent Stove Dimensions Jefferson dimensionsLocating The Stove Installation RequirementsClearance Requirements Wall and Ceiling Clearances Wall Centerline from FloorHearth Requirements Gas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal Termination Direct Vent onlyVertical Termination Direct Vent only Restictor Plate is used on Direct Vent installations onlyVent Termination Clearances Location of Vent Termination Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesVenting Requirements and Options Direct Vent only Approved Vent System ComponentsAssembly Procedures Install the Optional FanTools Required Unpack the StoveInstall the Vent Adapter Pipe Venting System Assembly Direct Vent General InformationFor Canadian installations The venting system must Attach the Inner Vent Assembly to the stove Attach inner assembly to flue collarSide Wall Termination Assembly Simpson Dura-Vent install outer adapter pipeVent Termination Below Grade Measure the horizontal lengthVertical Through the Roof Vent Assembly Venting System Assembly Natural Vent General InformationInstall the Vent Pipe Install the Log Set Air Shutter Adjustment Air Shutter Adjustment InstructionsAir Shutter Adjustment Connect the Gas Supply LineRemove stove front Complete the Assembly Install ON/OFF SwitchInstall the Stove Front Thermostat Connection optionalFlame & Temperature Adjustment Flame CharacteristicsOperation Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionConversion Precautions Conversion ProcedureFuel Conversion Instructions Pilot TypeInjector Orifice Size Matrix Conversion to LP Input BTU/hMaintenance Gasket Replacement Stove DisassemblyInspect the Vent System Annually Check the Gas Flame RegularlyWiring Diagrams BLKJefferson Direct Vent/Natural Vent Gas Heater DescriptionDescripción Fuel Conversion KitsOptional Accessories Remote ControlsFan Kits Decorative Rings3636 Jefferson Direct Vent /Natural Vent Gas Heater 3838 CFM Corporation Toll Free Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %