Century Jefferson Operation, Your First Fire, Pilot and Burner Inspection, Flame Characteristics

Page 25

Jefferson Direct Vent /Natural Vent Gas Heater

Operation

Your First Fire

Read these instructions carefully and familiarize yourself with the burner controls shown in Figure 47. Locate the pilot assembly, Figure 46. Follow the lighting instructions on Page 26 exactly.

During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within the first eight to ten hours, however, you can open a window to provide fresh air to alleviate the condition.

Pilot and Burner Inspection

Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Fig- ures 48, 49, 50. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas techni- cian for assistance. Do not operate the heater until the pilot flame is correct.

Follow regular maintenance procedures as described on Page 30.

 

 

Pilot Assembly

 

Thermocouple

ST232

 

 

Fig. 46

Pilot assembly location.

 

Flame & Temperature Adjustment

For stoves equipped with HI/LO valves, flame adjust- ment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas control valve. (Fig. 47)

Turn

 

 

 

counterclockwise

��

��

Turn clockwise

to decrease

 

to increase

 

 

flame height

 

 

flame height

Flame Characteristics

It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to Fig- ures 48, 49, 50. If any of the flames appear abnormal, call a service person.

 

ST233

Fig. 48

Correct pilot flame appearance. PSE pilot.

CO105c

 

Fig. 49

Correct pilot flame pattern. SIT valve.

ST234

Fig. 50 Correct burner flame appearance.

Fig. 47 Flame adjustment knob for Honeywell valve.

30004177

25

Image 25
Contents Jefferson Direct Vent/Natural Vent Gas Heater Table of Contents Installation & Operating Instructions Gas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsJefferson dimensions Jefferson Direct Vent/Natural Vent Stove DimensionsLocating The Stove Installation RequirementsClearance Requirements Wall and Ceiling Clearances Wall Centerline from FloorHearth Requirements Gas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal Termination Direct Vent onlyVertical Termination Direct Vent only Restictor Plate is used on Direct Vent installations onlyVent Termination Clearances Location of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and Options Direct Vent onlyInstall the Optional Fan Assembly ProceduresTools Required Unpack the StoveInstall the Vent Adapter Pipe Venting System Assembly Direct Vent General InformationFor Canadian installations The venting system must Attach inner assembly to flue collar Attach the Inner Vent Assembly to the stoveSimpson Dura-Vent install outer adapter pipe Side Wall Termination AssemblyMeasure the horizontal length Vent Termination Below GradeVenting System Assembly Natural Vent General Information Vertical Through the Roof Vent AssemblyInstall the Vent Pipe Install the Log Set Air Shutter Adjustment Instructions Air Shutter AdjustmentAir Shutter Adjustment Connect the Gas Supply LineRemove stove front Install ON/OFF Switch Complete the AssemblyInstall the Stove Front Thermostat Connection optionalFlame Characteristics Flame & Temperature AdjustmentOperation Your First FireTo Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemConversion Procedure Conversion PrecautionsFuel Conversion Instructions Pilot TypeConversion to LP Input BTU/h Injector Orifice Size MatrixMaintenance Stove Disassembly Gasket ReplacementInspect the Vent System Annually Check the Gas Flame RegularlyBLK Wiring DiagramsDescription Jefferson Direct Vent/Natural Vent Gas HeaterFuel Conversion Kits DescripciónRemote Controls Optional AccessoriesFan Kits Decorative Rings3636 Jefferson Direct Vent /Natural Vent Gas Heater 3838 CFM Corporation Toll Free Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings