Fig. 21 Simpson Dura-Vent - install outer adapter pipe.

Side Wall Termination Assembly

1.Locate the vent opening on the wall. Refer to Page 7, Figure 5, to determine the opening centerline.

It may be necessary to first position the stove and measure to find the hole location. Depending on whether the wall is made of combustible materi- als, cut the opening to the size shown in Figure 22. Combustible wall openings must be framed as shown in Figure 22.

CFM System

 

9³⁄

 

 

 

 

 

 

 

 

(240mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9³⁄

(240mm)

Combustible Wall

Jefferson Direct Vent /Natural Vent Gas Heater

12”

 

(305mm)

Sleeve

Max. Length

 

 

#8 Sheet

 

Metal Screws

Firestop

ZCS103

 

Fig. 23 Assemble the wall sleeve and firestop.

 

For DuraVent pipe only: Install vent pipe by align- ing the locking system together, sliding the pipes together and twisting clockwise.

Install 90° elbow. Twist lock as before.

Slide the wall plate over horizontal run before at- taching the horizontal run to the elbow. Fasten wall plate to wall.

4.For CFM Vent Pipe only: If necessary, measure to determine the vertical length (X) of pipe required from the adapter pipe to the wall cutout centerline, including a 2” overlap at the joint. (Fig. 24) use a hacksaw or tin snips to trim the pipe as needed.

DuraVent System

10”

(254mm)

VO584-100

10”

(254mm)

Framing Detail

7¹⁄₂

Noncombustible

Wall

X

Fig. 22 Locate vent opening.

2.Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”). Assemble the sleeve with the #8 sheet metal screws supplied. Attach the firestop plate to the sleeve end with the holes. (Fig. 23) NOTE: The wall sleeve is required in combustible walls only.

3.Install the Wall Firestop/Sleeve assembly into the wall cutout and fasten the firestop to the wall cutout framing members. (Fig. 23)

ST214

Fig. 24 Determine the vertical pipe length.

5.Install first the inner then the outer straight pipe section(s), trimmed end down, to the point of the el- bow. Drill 3 holes through each joint and fasten with sheet metal screws.

30004177

17

Image 17
Contents Jefferson Direct Vent/Natural Vent Gas Heater Table of Contents Installation & Operating Instructions Gas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsJefferson dimensions Jefferson Direct Vent/Natural Vent Stove DimensionsClearance Requirements Installation RequirementsLocating The Stove Hearth Requirements Wall Centerline from FloorWall and Ceiling Clearances Gas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal Termination Direct Vent onlyVent Termination Clearances Restictor Plate is used on Direct Vent installations onlyVertical Termination Direct Vent only Location of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and Options Direct Vent onlyInstall the Optional Fan Assembly ProceduresTools Required Unpack the StoveFor Canadian installations The venting system must Venting System Assembly Direct Vent General InformationInstall the Vent Adapter Pipe Attach inner assembly to flue collar Attach the Inner Vent Assembly to the stoveSimpson Dura-Vent install outer adapter pipe Side Wall Termination AssemblyMeasure the horizontal length Vent Termination Below GradeVenting System Assembly Natural Vent General Information Vertical Through the Roof Vent AssemblyInstall the Vent Pipe Install the Log Set Air Shutter Adjustment Instructions Air Shutter AdjustmentAir Shutter Adjustment Connect the Gas Supply LineRemove stove front Install ON/OFF Switch Complete the AssemblyInstall the Stove Front Thermostat Connection optionalFlame Characteristics Flame & Temperature AdjustmentOperation Your First FireTo Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemConversion Procedure Conversion PrecautionsFuel Conversion Instructions Pilot TypeConversion to LP Input BTU/h Injector Orifice Size MatrixMaintenance Stove Disassembly Gasket ReplacementInspect the Vent System Annually Check the Gas Flame RegularlyBLK Wiring DiagramsDescription Jefferson Direct Vent/Natural Vent Gas HeaterFuel Conversion Kits DescripciónRemote Controls Optional AccessoriesFan Kits Decorative Rings3636 Jefferson Direct Vent /Natural Vent Gas Heater 3838 CFM Corporation Toll Free Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings