Century Jefferson manual Lighting and Operating Instructions, To Turn Off Gas To Heater

Page 26

Jefferson Direct Vent/Natural Vent Gas Heater

Lighting and Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A.This heater has a pilot which must be lit manu- ally. When lighting the pilot follow these instruc- tions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neigh- bor’s phone. Follow the gas supplier’s instruc- tions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise to “OFF”.

 

 

 

 

PILOT

PILOT

OFF

 

 

 

 

 

t

 

1

F

 

 

 

 

 

 

 

lo

 

 

ON

ON

 

P

 

 

 

F

 

 

F

 

i

 

2

 

 

 

 

O

 

O

 

 

 

F

 

 

 

 

 

 

5

 

3

 

FFO

 

 

4

 

 

 

 

 

 

 

 

 

 

Euro SIT

SIT NOVA

Honeywell

6.Remove glass door before lighting pilot. (See Glass Frame Removal section).

7.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety infor- mation above. If you do not smell gas, go to the next step.

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to “PILOT”.

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depress- ing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to “OFF” and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1.Turn the On/Off switch to Off position or set the thermostat to lowest setting.

2.Turn off all electric power to the fireplace if service is to be performed.

3.Open control access panel.

4.Push in gas control knob slightly and turn clock-

wise to “OFF”. Do not force.

5.Close control access panel.

2626

30004177

Image 26
Contents Jefferson Direct Vent/Natural Vent Gas Heater Table of Contents Installation & Operating Instructions Requirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedJefferson Direct Vent/Natural Vent Stove Dimensions Jefferson dimensionsClearance Requirements Installation RequirementsLocating The Stove Hearth Requirements Wall Centerline from FloorWall and Ceiling Clearances High Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal Termination Direct Vent onlyVent Termination Clearances Restictor Plate is used on Direct Vent installations onlyVertical Termination Direct Vent only Location of Vent Termination Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesVenting Requirements and Options Direct Vent only Approved Vent System ComponentsTools Required Assembly ProceduresInstall the Optional Fan Unpack the StoveFor Canadian installations The venting system must Venting System Assembly Direct Vent General InformationInstall the Vent Adapter Pipe Attach the Inner Vent Assembly to the stove Attach inner assembly to flue collarSide Wall Termination Assembly Simpson Dura-Vent install outer adapter pipeVent Termination Below Grade Measure the horizontal lengthVertical Through the Roof Vent Assembly Venting System Assembly Natural Vent General InformationInstall the Vent Pipe Install the Log Set Air Shutter Adjustment Air Shutter AdjustmentAir Shutter Adjustment Instructions Connect the Gas Supply LineRemove stove front Install the Stove Front Complete the AssemblyInstall ON/OFF Switch Thermostat Connection optionalOperation Flame & Temperature AdjustmentFlame Characteristics Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionFuel Conversion Instructions Conversion PrecautionsConversion Procedure Pilot TypeInjector Orifice Size Matrix Conversion to LP Input BTU/hMaintenance Inspect the Vent System Annually Gasket ReplacementStove Disassembly Check the Gas Flame RegularlyWiring Diagrams BLKJefferson Direct Vent/Natural Vent Gas Heater DescriptionDescripción Fuel Conversion KitsFan Kits Optional AccessoriesRemote Controls Decorative Rings3636 Jefferson Direct Vent /Natural Vent Gas Heater 3838 CFM Corporation Toll Free Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %