7Installation of Fireplace
Caution! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp.
A. Things to Consider
•Location of chimney air kit (see Figure 7.4)
•Location of outside air kit
•Electrical connections and/or wall switch
•Gas line piping
B. Position the Fireplace
•Place the fireplace on a continuous flat surface.
•Follow framing instructions in Section 6.
Warning! Risk of Fire! Prevent contact with sag- ging, loose insulation.
•DO NOT install against vapor barriers or exposed insulation.
•Secure insulation and vapor barriers.
•Provide minimum air space clearances at the sides and back of the fireplace assembly as outlined in Section 6.
C. Place Protective Metal Hearth Strips
Warning! Risk of Fire! Protective metal hearth strips MUST be installed. DO NOT cover metal strips with com- bustible materials. Sparks or embers may ignite flooring.
•Refer to Figures 7.1 and 7.2.
•Locate the two protective metal hearth strips measuring approximately 26 in. x 4 in. (660 mm x 102 mm) included with this fireplace.
•Slide each metal strip 2 in. (51 mm) under front edge of fireplace.
•Overlap strips in the middle of the front fireplace opening by 1 in. (25 mm) minimum.
•Metal strips must extend beyond the front and sides of the fireplace opening by at least 2 in. (51 mm).
•Protect the front of a platform elevated above the hearth extension with metal strips (not included with fireplace) per Figure 7.2. See Section 11 for hearth extension instructions.
D. Level Fireplace
•Level fireplace
•Shim with
•Secure fireplace to framing with nailing flanges with a minimum of two fasteners per nailing flange.
•Check fireplace opening for square to ensure proper fit of glass doors. Measure diagonals of fireplace opening to make sure they are equal.
1" OVERLAP
Metal strip 2 in. (51 mm) under edge of fireplace openings and hearth extension.
Figure 7.1 Position the Protective Metal Hearth Strips
| Top piece must overlap |
| bottom piece |
| Raised Platform |
2 in. | 1 in. (25 mm) min. |
(51 mm) | overlap |
Floor
2 in.
(51 mm)
Figure 7.2 Protect the Front of an Elevated Platform
22 | Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12 |