Heatiator CL36D 1Listing and Code Approvals, A. Appliance Certification, C. Combustible Materials

Page 6
1Listing and Code Approvals

1Listing and Code Approvals

A. Appliance Certification

This fireplace system has been tested and listed in accor- dance with UL 127 and ULC-S610 standards by Under- writers Laboratories Inc. for installation and operation in the United States and Canada.

This fireplace may be installed in sleeping rooms EX- CEPT in manufactured homes. If installed with a gas log set, provisions for the National Fuel Gas Code must be met.

This fireplace has been tested and listed for use with the optional components specified in this manual. These op- tional components may be purchased separately and in- stalled at a later date. Installation of an outside air kit will require significant reconstruction and is best if installed at the time of fireplace installation.

Heatilator is a registered trademark of Hearth & Home Technologies Inc.

Warning! Risk of Fire! Hearth & Home Technologies disclaims any responsibility for, and the warranty and agency listing will be voided by the following actions.

DO NOT:

install or operate damaged fireplace

modify fireplace

install other than as instructed by Hearth & Home Technologies

operate the fireplace without fully assembling all components

overfire

install an unvented gas log set

install any component not approved by Hearth & Home Technologies

install parts or components not Listed or approved

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified installer, service agency or your dealer.

NoTICE: This fireplace is tested and approved as a decorative fireplace. It should not be factored as a primary heat source in residential heating calculations.

B. Non-Combustible Materials

Materials which will not ignite and burn, composed of any combination of the following:

-

Steel

-

Iron

-

Brick

-

Tile

-

Concrete

-

Slate

-

Glass

-

Plasters

Materials reported as passing ASTM E 136, Standard

Test Method for Behavior of Metals, in a Vertical Tube Furnace at 750° C

C. Combustible Materials

Materials made of or surfaced with any of the following materials:

-

Wood

-

Compressed paper

-

Plant fibers

-

Plastic

Any material that can ignite and burn; flame proofed or not, plastered or un-plastered

6

Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12

Image 6
Contents Wood Burning Fireplace Owner’s ManualModels CL36D CR36D Listing Label Information/Location CongratulationsHomeowner Reference Information FIREPLACE NOSafety Alert Key Table of ContentsInstaller Guide User GuideWARRANTY COVERAGE Limited Warranty Hearth & Home Technologies IncLIMITED LIFETIME WARRANTY WARRANTY PERIODThis warranty is void if WARRANTY CONDITIONSWARRANTY EXCLUSIONS LIMITATIONS OF LIABILITYB. Non-CombustibleMaterials 1Listing and Code ApprovalsA. Appliance Certification C. Combustible MaterialsA. Your Fireplace User Guide2Operating Instructions Hot glass will cause burnsD. Grate B. Seasoned WoodC. Starting a Fire E. FirescreenJ. Vented Gas Log Sets & Gas Log Lighters H. Glass DoorsI. Outside Air optional K. Optional ComponentsMoisture M. Wood FuelHardwood vs Softwood Seasoned WoodA. Disposal of Ashes 3Maintenance and ServiceB. Chimney Inspection/Cleaning Creosote - Formation and Need for RemovalD. Inspect Grate E. Glass CleaningC. Check Firebox Refractory Frequency: As desiredSolution 4Troubleshooting GuideStart Fire Problems Possible CauseA. Typical Fireplace System Installer Guide5Getting Started •Illustrations/diagrams are not drawn to scaleB. Design and Installation Considerations C. DraftD. Negative Pressure E. Locating Fireplace & Chimney F. Tools and Supplies Needed G. Fireplace System RequirementsH. Inspect Fireplace and Components 6Framing & Clearances A. Select Fireplace LocationB. Clearances Heatilator • CL36D, CR36D • 12538 • Rev Z 7/1239 deg C. Sidewalls/Surrounds20 in 50 degD. Frame the Fireplace B. Position the Fireplace 7Installation of FireplaceA. Things to Consider C. Place Protective Metal Hearth StripsCanada Note: Chimney air kit notshown, but required in Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12E. Install Outside Air Kit 8Chimney Assembly A. Chimney Requirements TableB. Using Offsets/Returns TableExample D. Install Chimney Air Kit E. Install Ceiling FirestopsC. Assemble Chimney Sections F. Install Attic Insulation Shield H. Complete Installation I. Install FlashingG. Cut out Hole in Roof J. Chimney Termination Requirements 9Chase Installations A. Construct the ChaseC. Install Chase Top B. Install Fireplace & ChimneyD. Install Termination Cap •Warning! Risk of Fire! The minimum overlap of•ST375 Square Termination Cap •TR342 Round Telescoping Termination Cap•TS345/TS345P Square Termination Cap •TCT375 Terra Cotta Cap10 Shrouds A. Radiation ShieldB. Field Constructed Shrouds Roofed Style Shroud radiation shield required Figure 10.4 Roofed Style Shroud DimensionsMailbox Style Shroud radiation shield required Heatilator CL36D, CR36D 12538 Rev Z 7/12B. Combustible Materials 11 FinishingA. Non-combustibleMaterials C. Hearth ExtensionD. Finishing Material Warning! Risk of FireE. Combustible Mantel MantelSidewalls/Surrounds B. Wood Burning Inserts 12 AccessoriesA. Gas Log/Lighter Provision Gas Code, ANSI Z223.1A. Fireplace Dimensions 13 Reference MaterialsB. Optional Components C. Chimney Components Catalog #14-1/2in 368 mmHeatilator • CL36D, CR36D • 12538 • Rev Z 7/12 Stocked D. Service PartsCL36D at DepotStocked D. Service Parts continuedCR36D at DepotDO NOT DISCARD THIS MANUAL – NOTES –E. Contact Information DO DISCARDNOT