Heatiator CL36D owner manual B. Using Offsets/Returns, Table, Example

Page 27
B. Using Offsets/Returns

B. Using Offsets/Returns

Use an offset/return to bypass overhead obstructions.

An offset and return can be used as a single entity or separated by chimney section(s).

Warning! Risk of Fire! Do not use offset/returns greater than 30°. Chimney draft will be restricted and could cause overheating and fire.

Measure the shift needed to avoid the overhead obstruction. Refer to dimension A in Figure 8.3.

Find the appropriate A dimension listed in Table 8.2.

The B dimension coinciding with the A dimension measurement in Table 8.2 represents the required vertical clearance needed to complete the offset/return.

Read across the chart to find the number of chimney sections/model numbers needed between the offset and return.

Example: A Manual backgroundManual background

B

1-1/4 in. (32 mm)

OVERLAP

Figure 8.3 Chimney Offset/Return

Example:

Your “A” dimension from Figure 8.3 is 14 1/2 in. (368 mm). Using Table 8.2 the dimension closest to, but not less than 14 1/2 in. (368 mm) is 14 1/2 in. (368 mm) using a 30° offset/return.

You determine from the table that you need 34 1/8 in. (867 mm) (Dimension “B”) between the offset and return.

The chimney component that best fits your applica- tion is one SL324.

Table 8.2

 

 

15-degree

 

 

 

 

 

 

 

 

 

 

30-degree

 

 

 

A

 

B

 

 

 

 

 

 

 

A

 

B

Offset

Height

 

 

 

 

 

 

Offset

Height

in.

 

mm

in.

 

mm

SL306

SL312

SL318

SL324

SL336

SL348

in.

 

mm

in.

 

mm

1-5/8

 

41

13-3/8

 

340

-

-

-

-

-

-

3-5/8

 

92

15-1/2

 

394

2-7/8

 

73

17-3/4

 

451

1

-

-

-

-

-

5-1/2

 

140

18-5/8

 

473

4-1/8

 

102

22-3/8

 

568

2

-

-

-

-

-

7-1/4

 

184

21-3/4

 

552

4-1/2

 

114

23-5/8

 

600

-

1

-

-

-

-

8-1/2

 

216

23-3/4

 

603

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-3/4

 

146

28-1/4

 

718

1

1

-

-

-

-

10-1/4

 

260

27

 

686

6

 

152

29-3/8

 

746

-

-

1

-

-

-

11-1/2

 

292

29

 

737

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-1/4

 

184

34

 

864

-

2

-

-

-

-

13-1/4

 

337

32-1/8

 

816

7-3/4

 

197

36-1/8

 

918

-

-

-

1

-

-

14-1/2

 

368

34-1/8

 

867

8-3/4

 

222

39-3/4

 

1010

1

-

-

1

-

-

16-1/4

 

413

37-3/8

 

949

10-3/8

 

264

45-5/8

 

1159

-

-

2

-

-

-

19-1/4

 

489

42-1/2

 

1080

10-5/8

 

270

46-3/4

 

1187

-

-

-

-

1

-

20-1/2

 

521

44-5/8

 

1133

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-7/8

 

302

51-3/8

 

1305

1

-

-

-

1

-

22-1/4

 

565

47-3/4

 

1213

13-1/2

 

243

57-1/4

 

1454

-

-

-

2

-

-

25-1/4

 

641

52-7/8

 

1343

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13-3/4

 

349

58-3/8

 

1483

-

-

-

-

-

1

26-1/2

 

673

55

 

1397

15

 

381

63

 

1600

1

-

-

-

-

1

28-1/4

 

718

58-1/8

 

1476

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-1/2

 

419

68-3/4

 

1746

-

1

-

-

-

1

31-1/4

 

794

63-1/4

 

1607

18

 

457

74-5/8

 

1895

-

-

1

-

-

1

34-1/4

 

870

68-1/2

 

1740

19-5/8

 

498

80-3/8

 

2042

-

-

-

1

-

1

37-1/4

 

946

73-3/4

 

1873

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20-5/8

 

524

84-1/8

 

2137

1

-

-

1

-

1

39-1/8

 

994

76-7/8

 

1953

22-3/4

 

578

91-7/8

 

2334

-

-

-

-

1

1

43-1/4

 

1099

84-1/8

 

2137

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

610

96-1/2

 

2451

1

-

-

-

1

1

45-1/8

 

1146

87-1/4

 

2216

25-7/8

 

657

103-1/2

 

2629

-

-

-

-

-

2

49-1/4

 

1251

94-1/2

 

2400

Proper assembly of air-cooled chimney parts result in an overlap at chimney joints of 1-1/4 in. (32 mm). Effective length is built into this chart.

Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12

27

Image 27
Contents Wood Burning Fireplace Owner’s ManualModels CL36D CR36D FIREPLACE NO CongratulationsHomeowner Reference Information Listing Label Information/LocationUser Guide Table of ContentsInstaller Guide Safety Alert KeyWARRANTY PERIOD Limited Warranty Hearth & Home Technologies IncLIMITED LIFETIME WARRANTY WARRANTY COVERAGELIMITATIONS OF LIABILITY WARRANTY CONDITIONSWARRANTY EXCLUSIONS This warranty is void ifC. Combustible Materials 1Listing and Code ApprovalsA. Appliance Certification B. Non-CombustibleMaterialsHot glass will cause burns User Guide2Operating Instructions A. Your FireplaceE. Firescreen B. Seasoned WoodC. Starting a Fire D. GrateK. Optional Components H. Glass DoorsI. Outside Air optional J. Vented Gas Log Sets & Gas Log LightersSeasoned Wood M. Wood FuelHardwood vs Softwood MoistureCreosote - Formation and Need for Removal 3Maintenance and ServiceB. Chimney Inspection/Cleaning A. Disposal of AshesFrequency: As desired E. Glass CleaningC. Check Firebox Refractory D. Inspect GratePossible Cause 4Troubleshooting GuideStart Fire Problems Solution•Illustrations/diagrams are not drawn to scale Installer Guide5Getting Started A. Typical Fireplace SystemB. Design and Installation Considerations C. DraftD. Negative Pressure E. Locating Fireplace & Chimney F. Tools and Supplies Needed G. Fireplace System RequirementsH. Inspect Fireplace and Components A. Select Fireplace Location 6Framing & ClearancesHeatilator • CL36D, CR36D • 12538 • Rev Z 7/12 B. Clearances50 deg C. Sidewalls/Surrounds20 in 39 degD. Frame the Fireplace C. Place Protective Metal Hearth Strips 7Installation of FireplaceA. Things to Consider B. Position the FireplaceHeatilator • CL36D, CR36D • 12538 • Rev Z 7/12 Note: Chimney air kit notshown, but required in CanadaE. Install Outside Air Kit 8Chimney Assembly Table A. Chimney RequirementsB. Using Offsets/Returns TableExample D. Install Chimney Air Kit E. Install Ceiling FirestopsC. Assemble Chimney Sections F. Install Attic Insulation Shield H. Complete Installation I. Install FlashingG. Cut out Hole in Roof J. Chimney Termination Requirements A. Construct the Chase 9Chase Installations•Warning! Risk of Fire! The minimum overlap of B. Install Fireplace & ChimneyD. Install Termination Cap C. Install Chase Top•TCT375 Terra Cotta Cap •TR342 Round Telescoping Termination Cap•TS345/TS345P Square Termination Cap •ST375 Square Termination Cap10 Shrouds A. Radiation ShieldB. Field Constructed Shrouds Heatilator CL36D, CR36D 12538 Rev Z 7/12 Figure 10.4 Roofed Style Shroud DimensionsMailbox Style Shroud radiation shield required Roofed Style Shroud radiation shield requiredC. Hearth Extension 11 FinishingA. Non-combustibleMaterials B. Combustible MaterialsWarning! Risk of Fire D. Finishing MaterialMantel E. Combustible MantelSidewalls/Surrounds Gas Code, ANSI Z223.1 12 AccessoriesA. Gas Log/Lighter Provision B. Wood Burning InsertsA. Fireplace Dimensions 13 Reference MaterialsB. Optional Components Catalog # C. Chimney Components368 mm 14-1/2inHeatilator • CL36D, CR36D • 12538 • Rev Z 7/12 at Depot D. Service PartsCL36D Stockedat Depot D. Service Parts continuedCR36D StockedDO DISCARDNOT – NOTES –E. Contact Information DO NOT DISCARD THIS MANUAL