Heatiator CL36D B. Design and Installation Considerations, C. Draft, D. Negative Pressure

Page 15

B. Design and Installation Considerations

Notice: Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits.

Before installing, determine the following:

Where the fireplace is to be installed

The vent system configuration to be used

Gas supply piping

Electrical wiring

Framing and finishing details

Whether optional accessories—devices such as a fan, wall switch or remote control­—are desired

Notice: Junction box should be installed during initial setup to avoid major reconstruction.

C. Draft

Draft is the pressure difference needed to vent fireplaces successfully. When a fireplace is drafting successfully, all combustion byproducts are exiting the home through the chimney.

Considerations for successful draft include:

Preventing negative pressure

Location of fireplace and chimney

NoTICE: Hearth & Home Technologies assumes no responsibility for the improper performance of the fireplace system caused by:

Inadequate draft due to environmental conditions

Downdrafts

Tight sealing construction of the structure

Mechanical exhausting devices

Improper location of the chimney

D. Negative Pressure

Warning! Risk of Asphyxiation! Negative pressure can cause spillage of combustion fumes and soot. Fire must draft properly for safe operation.

Negative pressure results from the imbalance of air avail- able for the fireplace to operate properly. It can be stron- gest in lower levels of the house.

Causes include:

Exhaust fans (kitchen, bath, etc.)

Range hoods

Combustion air requirements for furnaces, water heaters and other combustion appliances

Clothes dryers

Location of return-air vents to furnace or air conditioning

Imbalances of the HVAC air handling system

Upper level air leaks such as:

-Recessed lighting

-Attic hatch

-Duct leaks

To minimize the effects of negative air pressure:

Install the outside air kit with the intake facing prevailing winds during the heating season

Ensure adequate outdoor air for all combustion appliances and exhaust equipment

Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the fireplace

Avoid installing the fireplace near doors, walkways or small isolated spaces

Recessed lighting should be a “sealed can” design

Attic hatches weather stripped or sealed

Attic mounted duct work and air handler joints and seams taped or sealed

Basement installations should be avoided

NoTICE: Hearth & Home Technologies Inc. recommends the use of direct vent fireplaces in basements.

Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12

15

Image 15
Contents Wood Burning Fireplace Owner’s ManualModels CL36D CR36D FIREPLACE NO CongratulationsHomeowner Reference Information Listing Label Information/LocationUser Guide Table of ContentsInstaller Guide Safety Alert KeyWARRANTY PERIOD Limited Warranty Hearth & Home Technologies IncLIMITED LIFETIME WARRANTY WARRANTY COVERAGELIMITATIONS OF LIABILITY WARRANTY CONDITIONSWARRANTY EXCLUSIONS This warranty is void ifC. Combustible Materials 1Listing and Code ApprovalsA. Appliance Certification B. Non-CombustibleMaterialsHot glass will cause burns User Guide2Operating Instructions A. Your FireplaceE. Firescreen B. Seasoned WoodC. Starting a Fire D. GrateK. Optional Components H. Glass DoorsI. Outside Air optional J. Vented Gas Log Sets & Gas Log LightersSeasoned Wood M. Wood FuelHardwood vs Softwood MoistureCreosote - Formation and Need for Removal 3Maintenance and ServiceB. Chimney Inspection/Cleaning A. Disposal of AshesFrequency: As desired E. Glass CleaningC. Check Firebox Refractory D. Inspect GratePossible Cause 4Troubleshooting GuideStart Fire Problems Solution•Illustrations/diagrams are not drawn to scale Installer Guide5Getting Started A. Typical Fireplace SystemB. Design and Installation Considerations C. DraftD. Negative Pressure E. Locating Fireplace & Chimney F. Tools and Supplies Needed G. Fireplace System RequirementsH. Inspect Fireplace and Components A. Select Fireplace Location 6Framing & ClearancesHeatilator • CL36D, CR36D • 12538 • Rev Z 7/12 B. Clearances50 deg C. Sidewalls/Surrounds20 in 39 degD. Frame the Fireplace C. Place Protective Metal Hearth Strips 7Installation of FireplaceA. Things to Consider B. Position the FireplaceHeatilator • CL36D, CR36D • 12538 • Rev Z 7/12 Note: Chimney air kit notshown, but required in CanadaE. Install Outside Air Kit 8Chimney Assembly Table A. Chimney RequirementsB. Using Offsets/Returns TableExample D. Install Chimney Air Kit E. Install Ceiling FirestopsC. Assemble Chimney Sections F. Install Attic Insulation Shield H. Complete Installation I. Install FlashingG. Cut out Hole in Roof J. Chimney Termination Requirements A. Construct the Chase 9Chase Installations•Warning! Risk of Fire! The minimum overlap of B. Install Fireplace & ChimneyD. Install Termination Cap C. Install Chase Top•TCT375 Terra Cotta Cap •TR342 Round Telescoping Termination Cap•TS345/TS345P Square Termination Cap •ST375 Square Termination Cap10 Shrouds A. Radiation ShieldB. Field Constructed Shrouds Heatilator CL36D, CR36D 12538 Rev Z 7/12 Figure 10.4 Roofed Style Shroud DimensionsMailbox Style Shroud radiation shield required Roofed Style Shroud radiation shield requiredC. Hearth Extension 11 FinishingA. Non-combustibleMaterials B. Combustible MaterialsWarning! Risk of Fire D. Finishing MaterialMantel E. Combustible MantelSidewalls/Surrounds Gas Code, ANSI Z223.1 12 AccessoriesA. Gas Log/Lighter Provision B. Wood Burning InsertsA. Fireplace Dimensions 13 Reference MaterialsB. Optional Components Catalog # C. Chimney Components368 mm 14-1/2inHeatilator • CL36D, CR36D • 12538 • Rev Z 7/12 at Depot D. Service PartsCL36D Stockedat Depot D. Service Parts continuedCR36D StockedDO DISCARDNOT – NOTES –E. Contact Information DO NOT DISCARD THIS MANUAL
Related manuals