Adjacent combustible sidewalls must be located

• Combustible or non-combustible mantel legs, surrounds

 

a minimum of 18 in. (457 mm) from the fireplace

and stub walls may be constructed per Figure 11.5.

 

opening.

 

Manual background48 in. Min.

Manual backgroundManual background 36-5/8 in.Manual background

16 3/4 in.Manual background Minimum

20 in.

50 deg

48 in. Min.

 

BRICK

 

FRONT

 

4 in.

34 in.

14-1/2 in.

 

 

39 deg

 

18 in. Min.

20 in.

50 deg

16 3/4 in. Minimum

14-1/2 in.

39 deg

18 in. Min.

Figure 11.5 Mantel Leg or Wall Projections (acceptable on both sides of opening)

40

Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12

Image 40
Contents Owner’s Manual Wood Burning FireplaceModels CL36D CR36D Congratulations Homeowner Reference InformationListing Label Information/Location FIREPLACE NOTable of Contents Installer GuideSafety Alert Key User GuideLimited Warranty Hearth & Home Technologies Inc LIMITED LIFETIME WARRANTYWARRANTY COVERAGE WARRANTY PERIODWARRANTY CONDITIONS WARRANTY EXCLUSIONSThis warranty is void if LIMITATIONS OF LIABILITY1Listing and Code Approvals A. Appliance CertificationB. Non-CombustibleMaterials C. Combustible MaterialsUser Guide 2Operating InstructionsA. Your Fireplace Hot glass will cause burnsB. Seasoned Wood C. Starting a FireD. Grate E. FirescreenH. Glass Doors I. Outside Air optionalJ. Vented Gas Log Sets & Gas Log Lighters K. Optional ComponentsM. Wood Fuel Hardwood vs SoftwoodMoisture Seasoned Wood3Maintenance and Service B. Chimney Inspection/CleaningA. Disposal of Ashes Creosote - Formation and Need for RemovalE. Glass Cleaning C. Check Firebox RefractoryD. Inspect Grate Frequency: As desired4Troubleshooting Guide Start Fire ProblemsSolution Possible CauseInstaller Guide 5Getting StartedA. Typical Fireplace System •Illustrations/diagrams are not drawn to scaleC. Draft B. Design and Installation ConsiderationsD. Negative Pressure E. Locating Fireplace & Chimney G. Fireplace System Requirements F. Tools and Supplies NeededH. Inspect Fireplace and Components 6Framing & Clearances A. Select Fireplace LocationB. Clearances Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12C. Sidewalls/Surrounds 20 in39 deg 50 degD. Frame the Fireplace 7Installation of Fireplace A. Things to ConsiderB. Position the Fireplace C. Place Protective Metal Hearth StripsNote: Chimney air kit not shown, but required inCanada Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12E. Install Outside Air Kit 8Chimney Assembly A. Chimney Requirements TableTable B. Using Offsets/ReturnsExample E. Install Ceiling Firestops D. Install Chimney Air KitC. Assemble Chimney Sections F. Install Attic Insulation Shield I. Install Flashing H. Complete InstallationG. Cut out Hole in Roof J. Chimney Termination Requirements 9Chase Installations A. Construct the ChaseB. Install Fireplace & Chimney D. Install Termination CapC. Install Chase Top •Warning! Risk of Fire! The minimum overlap of•TR342 Round Telescoping Termination Cap •TS345/TS345P Square Termination Cap•ST375 Square Termination Cap •TCT375 Terra Cotta CapA. Radiation Shield 10 ShroudsB. Field Constructed Shrouds Figure 10.4 Roofed Style Shroud Dimensions Mailbox Style Shroud radiation shield requiredRoofed Style Shroud radiation shield required Heatilator CL36D, CR36D 12538 Rev Z 7/1211 Finishing A. Non-combustibleMaterialsB. Combustible Materials C. Hearth ExtensionD. Finishing Material Warning! Risk of FireE. Combustible Mantel MantelSidewalls/Surrounds 12 Accessories A. Gas Log/Lighter ProvisionB. Wood Burning Inserts Gas Code, ANSI Z223.113 Reference Materials A. Fireplace DimensionsB. Optional Components C. Chimney Components Catalog #14-1/2in 368 mmHeatilator • CL36D, CR36D • 12538 • Rev Z 7/12 D. Service Parts CL36DStocked at DepotD. Service Parts continued CR36DStocked at Depot– NOTES – E. Contact InformationDO NOT DISCARD THIS MANUAL DO DISCARDNOT
Related manuals
Manual 48 pages 11.28 Kb