Troubleshooting

TROUBLE

PROBABLE CAUSE

 

REMEDY

 

 

 

 

 

 

Unit

will

not

run

• Speed control in off position.

• Turn speed control clockwise.

and Fill Light is not

• Selected humidity level is

Raise humidistat setting if

on.

 

 

 

obtained.

 

desired.

 

 

 

 

• No power.

• Check 120 volt source for power.

 

 

 

 

 

 

 

Unit

will

not

shut

• Float is not free.

Free float from obstruction.

off.

 

 

 

 

 

 

 

 

 

 

 

 

Unit

will

not

dry

• This is normal.

• A small amount of water remains

out completely.

 

 

in the cabinet after fill light comes

 

 

 

 

 

 

on.

 

 

 

Bottle continues to

• Air is entering water bottle.

• Check “E-Z-Fill Side-Cap” and

empty.

 

 

 

 

valve assembly cap to ensure

 

 

 

 

 

 

tightness.

 

 

 

 

 

Check for leak in water bottle.

 

 

 

 

 

• Ensure gaskets for “E-Z-Fill Side

 

 

 

 

 

 

Cap” are in place (see repair

 

 

 

 

 

 

parts list).

 

 

 

 

 

Unit is not

 

• Dirty filters.

Change to fresh new filters.

emptying during

• Bottle cap plunger missing post

• Check orientation of bottle.

operation.

 

in bottom of cabinet.

 

Reposition so that bottle cap

 

 

 

 

 

 

plunger is depressed by post in

 

 

 

 

 

 

bottom of cabinet.

 

 

 

Bottle not empty-

• Unit is not set up on a level sur-

• Position unit level. (Some carpet

ing and/or fill

 

face. (Float will not sense water

 

padding may allow unit to set

indicator turns on

at the rear of the cabinet.)

 

lower on the left side than the

before bottle is

 

 

right side due to the weight of the

empty.

 

 

 

 

water bottle on the left side. Install

 

 

 

 

 

 

coasters under left casters to

 

 

 

 

 

 

level.

 

 

 

 

Water smells.

 

• Poor water conditions.

• Clean humidifier as instructed in

 

 

 

 

 

 

your Owner’s Manual

 

 

 

 

 

• Replace filters and use an EPA

 

 

 

 

 

 

Approved Bacteriostat.

 

 

 

No mist appears.

• This is an evaporative

• No mist will appear.

 

 

 

 

humidifier.

 

 

 

 

 

 

 

 

 

FOR TECHNICAL HELP

If in the USA call 1-800-654-3545

If in Canada call 1-888-744-4687

13

Image 13
Contents Emerson Limited Warranty General Safety InstructionsDescription HD7002 & HD7005 Know Your HumidifierHumidifier Operations AssemblyElectrical Hook-Up Water Fill Location InstructionsCheck for possible leaks by performing the following Humidity Control Operating Humidifier ControlsOperating Tips for Best Performance Using Your HumidifierReplacement and Care of Filters Replacement and Care of Filters Cleaning Your Humidifier Disinfecting Water Bottle Cabinet Removing ScaleTrouble Probable Cause Remedy TroubleshootingModel NO. HD7002 1 & HD7005 Repair PartsKey Model Description HD7002 HD7005 Repair PartsHighway Markham, Ontario Canada L3P 3J3