A. Chimney Requirements

Measure vertical distances from the base of the fireplace as shown in Figure 8.2.

• Minimum overall straight height

13

(3.96 m)

• Minimum height with offset/return

14.5 ft

(4.42 m)

• Maximum height

90 ft

(27.43 m)

• Maximum chimney length between an offset

20 ft

(6.1 m)

and return

 

 

• Maximum distance between chimney

35 ft

(10.67 m)

stabilizers

 

 

• Double offset/return minimum height

20 ft

(6.1 m)

• Maximum unsupported chimney length

6 ft

(1.83 m)

between the offset and return

 

 

• Maximum unsupported chimney height above

35 ft

(10.67 m)

the fireplace

 

 

• Maximum unsupported chimney above roof

6 ft

(1.83 m)

Warning! Risk of Fire! You must maintain 2 in. (51

mm)air space clearance to insulation and other combus- tible materials around the chimney system. Failure to do so may cause overheating and fire.

Table 8.1

Determine the chimney components needed to complete your particular installation:

Measure the total vertical height of the fireplace installation from the base of the fireplace assembly to the approximate location of the bottom of the termination cap.

Subtract the effective height of the fireplace assembly (see Figure 8.2) from the total vertical height to determine the overall height of the chimney installation.

Create a schematic for your application similar to Figure 8.2 showing components required (referring to Table 8.1). Figure 8.1 identifies those components and where used.

Install a ceiling firestop whenever the chimney penetrates a floor/ceiling.

Notice: A maximum of two pairs of offsets and returns may be used.

Caution! Risk of Fire and/or Asphyxiation! DO NOT connect this fireplace to a chimney flue servicing another appliance. Do NOT connect to any air distribu- tion duct or system. These actions could cause over- heating/fire in the chimney flue, or release of exhaust fumes into the living areas.

HEIGHT OF CHIMNEY COMPONENTS

in.

mm

Chimney Stabilizer

 

 

 

SL3

4-3/4

121

 

 

 

 

Ceiling Firestops

 

 

 

FS338

0

0

 

FS339

0

0

 

 

 

 

 

FS340

0

0

Offsets/Returns

 

 

 

SL315

13-3/8

340

 

SL330

15-1/2

394

Roof Flashing

 

 

 

RF370

0

0

 

RF371

0

0

 

 

 

 

Chimney Sections*

 

 

 

SL306

4-3/4

121

 

SL312

10-3/4

273

 

 

 

 

 

SL318

16-3/4

425

 

SL324

22-3/4

578

 

SL336

34-3/4

883

 

 

 

 

 

SL348

46-3/4

1187

* Dimensions reflect effective height.

 

 

20 ft (6.10 m) max. pipe between an offset & return

Ceiling Firestop

391/2 in. (1003 mm) Effective Height

6 ft (1.83 m) max. unsupported chimney above roof

35 ft (10.67 m)

max. straight unsupported chimney height

14.5ft (4.42 m) min. height/single offset-return 20 ft. (6.1 m) min. height/double offset-return

90 ft (27.43 m) max. height

Figure 8.2 Chimney Requirements

Heatilator • EL36/EL42 • 4044-132 • Rev AD• 7/12

25

Image 25
Contents Hot screen/mesh and glass doors will cause burns Wood Burning FireplaceFire Risk Listing Label Information/Location Homeowner Reference InformationInstaller Guide Table of ContentsUser Guide Limited Lifetime Warranty Warranty Hearth & Home Technologies IncThis warranty is void if Warranty ConditionsAppliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsYour Fireplace Operating InstructionsHot glass will cause burns Starting a Fire Seasoned WoodGrate FirescreenVented Gas Log Sets & Gas Log Lighters Glass DoorsOptional Components Clear SpaceWood Fuel Chimney Inspection/Cleaning Maintenance and ServiceDisposal of Ashes Creosote Formation and Need for RemovalCheck Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDraft Design and Installation ConsiderationsNegative Pressure Recommended Chimney Locations Locating Fireplace & ChimneyFireplace System Requirements Tools and Supplies NeededInspect Fireplace and Components Select Fireplace Location Framing & ClearancesClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsOutside Model #Things to Consider Installation of FireplacePosition the Fireplace Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet Outside Air Installation Install Outside Air KitChimney Assembly Chimney Requirements Chimney RequirementsExample Using Offsets/ReturnsDegree SL306 SL312 SL318 SL324 SL336 SL348Assemble Chimney Sections Install Chimney Air KitInstalling the Ceiling Firestop Install Ceiling FirestopsPrepare Attic Insulation Shield Install Attic Insulation ShieldInstall Flashing Complete InstallationFollowing steps should be skipped if using a chase Cut out Hole in RoofMultiple Chimney Locations Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyCap Install Termination CapTS345/TS345P Square Termination Cap Radiation Shield ShroudsField Constructed Shrouds Open Top Shroud TR342 caps require radiation shieldRoofed Style Shroud radiation shield required Mailbox Style Shroud radiation shield requiredTS345 TR342 TR342/344= 1/k x inches of thickness Hearth Extension FinishingMinimum MaterialModel # Raised Hearth Extension FramingRaised Platform Hearth Extension-Finishing Materi- als Non-combustible SealantDecorative Facing Finishing MaterialClearances to Mantels or other Combustibles above Fireplace Combustible Mantel4 in mm Gas Log/Lighter Provision AccessoriesWood Burning Inserts Gas Code, Ansi Z223.1Reference Materials Fireplace DimensionsMm HX4 Hearth Extension In. HX3 Hearth Extension 13 mmBifold Glass Doors DM1036, DM1042 AK24Catalog # Chimney ComponentsCeiling Firestop JB877 Chimney Joint BandCB876 Chimney Joint Band ST375 Square Termination CapCT35 Chase Top TCT375 Terra Cotta CapTS345/TS345P Square Termination Cap Damper Kit Air Handle Part number list on followingStocked Service PartsAt Depot Piece Rod EL42EL42 Contact Information