C. Chimney Components

The following pictures show only those chimney components which may be safely used with this fireplace.

Catalog #

Description

SL306

Chimney Section - 6 in. (152 mm) long

SL312

Chimney Section - 12 in. (305 mm) long

 

 

SL318

Chimney Section - 18 in. (457 mm) long

SL324

Chimney Section - 24 in. (610 mm) long

 

 

SL336

Chimney Section - 36 in. (914 mm) long

SL348

Chimney Section - 48 in. (1219 mm) long

 

 

SL3

Chimney Stabilizer

 

 

SL315

Chimney Offset/Return - 15 deg

SL330

Chimney Offset/Return - 30 deg

 

 

FS338

Ceiling Firestop - Straight

FS339

Ceiling Firestop - 15 deg

 

 

FS340

Ceiling Firestop - 30 deg

AS8

SL300 Straight Attic Insulation Shield, 24 in. (610 mm)

 

 

JB877

Chimney Joint Band

CB876

Chimney Bracket

RF370

Roof Flashing - Flat to 6/12 Pitch

 

 

RF371

Roof Flashing - 6/12 to 12/12 Pitch

TR344

Round Termination Cap

 

 

TR342

Round Telescoping Termination Cap

ST375

Square Termination Cap

 

 

TS345

Square Termination Cap

TS345P

Square Termination Cap - Painted

TCT375

Terra Cotta Termination Cap

CT35

Chase Top

DTO134

Short Octagon Decorative Cap

 

 

DTO146

Tall Octagon Decorative Cap

DTS134

Short Square Decorative Cap

 

 

DTS146

Tall Square Decorative Cap

LDS33

Decorative Shroud - 3 ft x 3 ft (.91 m x .91 m)

ID4 Insulated Duct

4 in. (102 mm) i

42 in.

(1067 mm)

UD4 Uninsulated Duct

4 in. (102 mm) i

42 in.

(1067 mm)

 

A

8 in.

10-1/2 in.

(267 mm)

(203 mm)

 

 

B

 

Chimney Sections

 

A

 

 

B

Catalog #

in

 

mm

in

 

mm

SL306

6

 

152

4-3/4

 

121

SL312

12

 

305

10-3/4

 

273

 

 

 

 

 

 

 

SL318

18

 

457

16-3/4

 

425

SL324

24

 

610

22-3/4

 

578

 

 

 

 

 

 

 

SL336

36

 

914

34-3/4

 

883

SL348

48

 

1219

46-3/4

 

1187

A = Actual Length

B = Effective Length (length of

chimney part after it has

been snapped to another)

LDS46

Decorative Shroud - 4 ft x 6 ft (1.22 m x 1.83 m)

 

 

LDS-BV

Decorative Shroud - 26 in. x 26 in. (660 mm x 660 mm)

 

 

 

Field Constructed Shrouds (See “Woodburning

 

Termination Cap”)

CT-3A

Adapter - May be used with the following copper caps

 

 

 

CT-Series

12 in.

(305 mm)

5-1/4 in. (133 mm)

10-1/2 in.

(287 mm)

12in.

(305 mm)

4 in. (102 mm)

DT-Series

CAK4A Chimney Air Kit

 

Inside

20-3/4 in.

Diameter

8 in.

(527 mm)

(203 mm)

4-3/4 in. (121 mm)

Outside

Diameter

Effective Height

10-1/2 in.

SL3 Vent Stabilizer

(267 mm)

Heatilator • EL36/EL42 • 4044-132 • Rev AD• 7/12

47

Image 47
Contents Fire Risk Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Listing Label Information/Location Homeowner Reference InformationUser Guide Table of ContentsInstaller Guide Limited Lifetime Warranty Warranty Hearth & Home Technologies IncThis warranty is void if Warranty ConditionsCombustible Materials Listing and Code ApprovalsAppliance Certification Non-Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Firescreen Seasoned WoodStarting a Fire GrateClear Space Glass DoorsVented Gas Log Sets & Gas Log Lighters Optional ComponentsWood Fuel Creosote Formation and Need for Removal Maintenance and ServiceChimney Inspection/Cleaning Disposal of AshesFrequency As desired Glass CleaningCheck Firebox Refractory Inspect GrateStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedNegative Pressure Design and Installation ConsiderationsDraft Recommended Chimney Locations Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Select Fireplace Location Framing & ClearancesClearances to Combustible Materials ClearancesModel # Sidewalls/SurroundsFrame the Fireplace OutsidePlace Protective Metal Hearth Strips Installation of FireplaceThings to Consider Position the FireplaceFt min. from top of uppermost chimney section to air inlet Outside Air Installation Install Outside Air KitChimney Assembly Chimney Requirements Chimney RequirementsSL306 SL312 SL318 SL324 SL336 SL348 Using Offsets/ReturnsExample DegreeAssemble Chimney Sections Install Chimney Air KitInstalling the Ceiling Firestop Install Ceiling FirestopsPrepare Attic Insulation Shield Install Attic Insulation ShieldCut out Hole in Roof Complete InstallationInstall Flashing Following steps should be skipped if using a chaseMultiple Chimney Locations Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyCap Install Termination CapTS345/TS345P Square Termination Cap Open Top Shroud TR342 caps require radiation shield ShroudsRadiation Shield Field Constructed ShroudsTR342/344 Mailbox Style Shroud radiation shield requiredRoofed Style Shroud radiation shield required TS345 TR342Material Finishing= 1/k x inches of thickness Hearth Extension MinimumModel # Raised Hearth Extension FramingRaised Platform Hearth Extension-Finishing Materi- als Non-combustible SealantDecorative Facing Finishing MaterialClearances to Mantels or other Combustibles above Fireplace Combustible Mantel4 in mm Gas Code, Ansi Z223.1 AccessoriesGas Log/Lighter Provision Wood Burning InsertsReference Materials Fireplace DimensionsAK24 In. HX3 Hearth Extension 13 mmMm HX4 Hearth Extension Bifold Glass Doors DM1036, DM1042Catalog # Chimney ComponentsST375 Square Termination Cap JB877 Chimney Joint BandCeiling Firestop CB876 Chimney Joint BandTS345/TS345P Square Termination Cap TCT375 Terra Cotta CapCT35 Chase Top Damper Kit Air Handle Part number list on followingAt Depot Service PartsStocked Piece Rod EL42EL42 Contact Information