D. Install Termination Cap
Install the chimney sections up through the chase enclo- sure.
• Caulk the overlap seam of any exposed pipe sections that are located above the roof line to prevent leaks.
•Refer to termination cap instructions.
Warning! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from cap. Separation allows sparks, heat and embers to escape.
Notice: Paint the termination cap with a
•TR344 Round Termination Cap
•TR342 Round Telescoping Termination Cap
Assemble | Termination | |
storm collar | ||
Cap | ||
around extended | ||
| ||
termination cap |
| |
pipe |
| |
once cap is |
| |
installed. | Do NOT | |
| ||
Caulk gaps between | block air | |
holes | ||
storm collar & pipe, | Storm | |
and storm collar | Collar | |
& chase top. | 3 clip brackets. | |
| Slip over chase collar | |
| and attach with screws | |
| provided. | |
Collar |
| |
2 in. (51 mm) | 14 1/2 in. (368 mm) | |
Minimum Height | ||
Maximum | ||
| ||
Chase Top |
|
Chase
Chimney
Pipe
Termination cap pipe and chimney section must overlap
Figure 9.5 Installing a TR342 Round Telescoping Termination
Termination
Cap
Slip
storm collar
around chimney pipe
Cap
•ST375 Square Termination Cap
before termination cap pipe is snapped into the chimney pipe.
Caulk gaps between | Storm | |
storm collar & pipe, | ||
Collar | ||
and storm collar | ||
| ||
& chase top. |
| |
Collar |
| |
2 in. (51 mm) | Chimney | |
Minimum Height | ||
Pipe | ||
| ||
Chase Top |
|
Do NOT
block air holes
6 in. (153 mm) Minimum top of chase to top of chimney pipe
Flange
Termination Cap
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Place waterproof caulk or sealer under each flange of the termination cap and on top of each screw to help prevent leaks.
The last section of pipe must stop between 2 in. (51
mm)above the top of the chase and 4 3/4 in. (121
mm) below the top of the chase.
2 in. (51 mm)
maximum
4 3/4 in. (121 mm)
maximum
Chase
Chimney
Pipe
Chase
Termination cap pipe and chimney section must be snapped together to maintain an overlap of
Figure 9.4 Installing a TR344 Round Termination Cap
Termination cap pipe and chimney section must overlap
Figure 9.6 Installing an ST375 Square Termination Cap
34 | Heatilator • EL36/EL42 • |