Hearth and Home Technologies ESCAPE-42DV owner manual Alcove Applications

Page 12

R

M

N

P

Q

(See Note 2)

V

T

VS Electrical S

Service

D*

V

V

V

= VENT TERMINAL

X = AIR SUPPLY INLET

= AREA WHERE TERMINAL IS NOT PERMITTED

A

=

12 inches

clearances above grade, veranda,

L**

=

.7 ft

clearance above paved

 

 

(See Note 1)

porch, deck or balcony

 

 

 

 

(See Note 1)

 

sidewalk or a paved driveway

B

=

12 inches

clearances to window or door

 

 

 

 

 

 

 

 

located on public property

M*** =

18 inches

clearance under veranda, porch,

 

 

 

that may be opened, or to perma-

 

 

 

nently closed window. (Glass)

 

 

 

 

 

 

 

 

deck, balcony or overhang

D*

=

24 inches

vertical clearance to unventilated

 

 

 

 

42 inches

vinyl

 

 

 

 

 

 

soffit or to ventilated soffit located

S

=

 

6 inches

clearance from sides of electri-

 

 

 

above the terminal

 

 

 

 

 

(See Note 5)

 

cal service

 

 

 

 

 

*42 inches

for vinyl clad soffits and below

T

=

12 inches

clearance above electrical

 

 

 

electrical service

 

 

 

 

(See Note 5)

 

service

 

 

 

F

=

9 inches

clearance to outside corner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alcove Applications

 

 

 

 

 

G

=

6 inches

clearance to inside corner

 

 

 

 

 

 

 

 

 

N

 

=

6 inches

non-vinyl sidewalls

 

H

=

3 ft. (Canada)

not to be installed above a gas

 

 

 

 

 

 

 

 

 

12 inches

vinyl sidewalls

 

 

 

 

meter/regulator assembly within 3

 

 

 

 

 

 

 

 

 

 

 

P

 

=

8 ft.

 

 

 

 

 

 

 

 

 

feet (90 cm) horizontally from the

 

 

 

 

 

 

 

 

 

 

 

 

center-line of the regulator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QMIN

 

RMAX

 

 

I

=

3 ft

clearance to gas service regulator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 cap

 

3 feet

 

2 x Q ACTUAL

 

 

 

 

 

vent outlet

 

 

 

 

 

 

 

 

J

=

9 inches (U.S.A.)

 

 

 

 

 

2 caps

 

6 feet

 

1 x Q ACTUAL

 

 

 

 

12 inches (Canada) clearance to non-mechanical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 caps

 

9 feet

 

2/3 x Q ACTUAL

 

 

 

 

 

air supply inlet to building or the

 

 

 

 

 

 

 

 

 

 

 

combustion air inlet to any other

 

 

 

 

4 caps

 

12 feet

 

1/2 x Q ACTUAL

 

 

 

 

 

appliance

 

 

 

 

 

 

 

 

 

 

 

 

 

K

=

3 ft. (U.S.A.)

 

 

 

QMIN

= # termination caps x 3

RMAX = (2 / # termination caps) x QACTUAL

 

 

 

 

 

 

 

 

 

 

6 ft. (Canada)

clearance to a mechanical (pow-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ered) air supply inlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or meets Note 2.

NOTE 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap shield is suggested. (See vents components page)

NOTE 2: Termination in an alcove space (spaces open only on one side and with an overhang) are permitted with the dimensions specified for

vinyl or non-vinyl siding and soffits. 1. There must be 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap.

Figure 4.4 Minimum Clearances for Termination

NOTE 3: Local codes or regulations may require different clearances.

NOTE 4: Termination caps may be hot. Consider their proximity to doors or other traffic areas.

NOTE 5: Location of the vent termination must not interfere with access to the electrical service.

WARNING: In the U.S: Vent system termination is NOT permitted in screened porches. You must follow side wall, overhang and ground clearances as stated in the instructions.

In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must follow all side walls, overhang and ground clearances as stated in the instructions.

Heat & Glo assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.

12

Heat & Glo • Escape-42DV2052-900 Rev. R • 10/08

Image 12 Contents
Model What to do if you smell gasHot glass will cause burns Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Inspect Firebox Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections Hearth ExtensionTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Vent Information and Diagrams Vent Table KeyMeasuring Standards Use of ElbowsVent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows H1+ H2Top Vent Horizontal Termination Three Elbows 12 ft V1 + V2 + H1 = 50 ft 15.2 m Max Top Vent Vertical Termination Three Elbows Ht MaxVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Removing Non-combustible Facing Mate- rial Assembly Appliance PreparationSecuring and Leveling the Appliance Installing Non-combustible Facing Material Attaching Non-combustible Facing MaterialInstalling Vent Pipe Assembly of Vent SectionsAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Termination Cap flue of the pipe see FigureAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Intellifire Ignition System WiringConnecting to the Appliance Optional Accessories RequirementsDetail a PVK-80 Motor Neutral Vacuum Switch 120VAC HOT Finishing Facing MaterialFinishing Materials Requirements Non-combustible Finishing Material RequirementsAppliance Setup Clean the ApplianceAccessories Ember PlacementPositioning the Logs StepLOG #1 SRV750-706 Three LOG #2 SRV569-705 TwoLOG #3 SRV2052-701 LOG #4 SRV2012-162LOG #5 SRV2012-163 LOG #6 SRV2052-702 LOG #7 SRV2012-165LOG #8 SRV2012-166 Final StepGlass Assembly Air Shutter SettingRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceTurn off all electric power to the appliance On position. The ON/OFF switch mayLighting Appliance IPI Ignition Final inspection byFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsAppliance Dimension Diagram Reference MaterialsLocation Inches Millimeters Vent Components Diagrams DVP vent componentsDVP-TRAP RF6M RF12M Log Set Assembly Service PartsPart number list on following Service Parts List StockedAt Depot IPI Valve Assembly StockedCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information