Hearth and Home Technologies ESCAPE-42DV Vent Diagrams, Top Vent Horizontal Termination One Elbow

Page 14

D. Vent Diagrams

WARNING

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling firestops.

ALWAYS maintain specified clearances around venting and firestop systems.

Install wall shield and ceiling firestops as specified.

Failure to keep insulation or other material away from vent pipe may cause fire.

1. Top Vent - Horizontal Termination

One Elbow

NOTE: A flue restrictor can

Note: Must have a 24

inches

only be used in vent runs that

minimum vertical vent

before

include no elbows and exceed

attaching any elbow to the unit.

30 ft. total of straight vertical.

 

 

V1

H1

V1 Minimum

H1

Maximum

2 ft

610 mm

7 in*

 

178 mm

3 ft

914 mm

2 ft

 

610 mm

4 ft

1.2 m

4 ft

 

1.2 m

 

 

 

 

 

5 ft

1.5 m

9 ft

 

2.7 m

 

 

 

 

 

6 ft

1.8 m

12 ft

 

3.7 m

7 ft

2.1 m

14 ft

 

4.3 m

10 ft

3.0 m

20 ft

 

6.1 m

 

 

 

 

 

20 ft

6.1 m

40 ft

 

12.2 m

After V1= 6 ft then H1 = 2 x V ft Maximum

V1 + H1 = 60 ft Maximum

*when used with approved termination caps

Figure 5.3

Two Elbows

NOTE: A flue restrictor can

 

 

 

 

Note: Must have a 24

inches

only be used in vent runs that

 

minimum vertical vent

before

include no elbows and exceed

 

attaching any elbow to the unit.

30 ft. total of straight vertical.

 

 

 

 

 

 

 

 

 

V1 Minimum

H1+ H2

3 ft

914 mm

18 in

457 mm

4 ft

1.2 m

3 ft

914 mm

 

 

 

 

5 ft

1.5 m

7 ft

2.1 m

 

 

 

 

6 ft

1.8 m

10 ft

3.0 m

7 ft

2.1 m

12 ft

3.7 m

10 ft

3.0 m

18 ft

5.5 m

 

 

 

 

20 ft

6.1 m

20 ft

6.1 m

 

 

 

 

After V1= 6 ft then H1 = 2 x V1 ft Maximum

V1 + H1 + H2= 60 ft Maximum

H1 + H2= 20 ft Maximum

H2H1

INSTALLED

HORIZONTALLY

Figure 5.4

V1

14

Heat & Glo • Escape-42DV2052-900 Rev. R • 10/08

Image 14
Contents Hot glass will cause burns ModelWhat to do if you smell gas Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Inspect Firebox Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections Hearth ExtensionSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Measuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsTwo Elbows Vent DiagramsTop Vent Horizontal Termination One Elbow H1+ H2Top Vent Horizontal Termination Three Elbows 12 ft V1 + V2 + H1 = 50 ft 15.2 m Max Top Vent Vertical Termination Three Elbows Ht MaxWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Securing and Leveling the Appliance Removing Non-combustible Facing Mate- rial AssemblyAppliance Preparation Installing Non-combustible Facing Material Attaching Non-combustible Facing MaterialAttaching Vent to the Firebox Assembly Installing Vent PipeAssembly of Vent Sections Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Heat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Installing Roof Flashing and Vertical Termination Cap flue of the pipe see FigureAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Connecting to the Appliance Recommendation for WireIntellifire Ignition System Wiring Optional Accessories RequirementsDetail a PVK-80 Motor Neutral Vacuum Switch 120VAC HOT Finishing Facing MaterialFinishing Materials Requirements Non-combustible Finishing Material RequirementsAccessories Appliance SetupClean the Appliance Ember PlacementPositioning the Logs StepLOG #1 SRV750-706 Three LOG #2 SRV569-705 TwoLOG #5 SRV2012-163 LOG #3 SRV2052-701LOG #4 SRV2012-162 LOG #8 SRV2012-166 LOG #6 SRV2052-702LOG #7 SRV2012-165 Final StepRemoving Glass Assembly Glass AssemblyAir Shutter Setting Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceLighting Appliance IPI Ignition Turn off all electric power to the applianceOn position. The ON/OFF switch may Final inspection byAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsLocation Inches Millimeters Appliance Dimension DiagramReference Materials Vent Components Diagrams DVP vent componentsDVP-TRAP RF6M RF12M Part number list on following Log Set AssemblyService Parts At Depot Service Parts ListStocked IPI Valve Assembly StockedCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

ESCAPE-42DV specifications

Hearth and Home Technologies has established itself as a leader in the hearth industry, bringing innovation and style to homes across North America. One of their standout offerings is the ESCAPE-42DV, a versatile and efficient direct vent gas fireplace that combines modern design with cutting-edge technology.

The ESCAPE-42DV features a sleek, contemporary look that seamlessly integrates into various home aesthetics. With a viewing area of 42 inches, it provides a wide and inviting flame display that enhances the ambiance of any living space. Its generous size makes it an ideal centerpiece for larger rooms, allowing for a captivating focal point in homes with open floor plans.

One of the notable characteristics of the ESCAPE-42DV is its direct vent technology, which allows for efficient operation without the need for a traditional chimney. This system ensures that combustion gases are expelled outside while bringing in fresh air for combustion, creating a cleaner and more energy-efficient environment. Homeowners can enjoy the warmth and comfort of real flames without the hassle of maintaining a complex venting system.

Efficiency is key in today's eco-conscious world, and the ESCAPE-42DV exceeds expectations with its impressive energy ratings. It operates at a high efficiency level, providing excellent heating capability while minimizing gas consumption. This not only reduces utility bills but also makes it an environmentally friendly choice, appealing to those who prioritize sustainability.

Hearth and Home Technologies have also incorporated advanced features into the ESCAPE-42DV, including a variety of heat and flame control options. The unit comes equipped with a programmable remote control, allowing users to adjust the flame height and heat output with ease. This personalization ensures comfort whether homeowners are looking for a cozy ambiance or substantial warmth during colder months.

The fireplace can be styled according to individual preferences, thanks to customizable options such as various media choices, including beautiful ceramic logs and glowing embers. The ability to personalize the appearance of the ESCAPE-42DV enhances its appeal, making it a functional yet stylish addition to any home.

With its combination of design elegance, innovative technology, and operational efficiency, the Hearth and Home Technologies ESCAPE-42DV direct vent gas fireplace is an exceptional choice for homeowners seeking to elevate their living spaces. It stands as a testament to the brand's commitment to quality and innovation in the hearth industry, delivering warmth and beauty to modern homes.