Hearth and Home Technologies ESCAPE-42DV Vent Components Diagrams, DVP vent components

Page 49

B. Vent Components Diagrams

 

Pipe

Effective Length

10-1/2 in.

 

Effective

Inches

Millimeters

(267 mm)

45°

 

Height/Length

DVP4

4

102

 

 

 

DVP6

6

152

 

 

 

DVP12

12

305

4-7/8 in.

 

 

DVP24

24

610

( 276 mm)

 

 

 

10-7/8 in.

 

DVP36

36

914

 

DVP Pipe (see chart)

 

(276 mm)

DVP48

48

1219

DVP45 (45 Elbow)°

 

 

DVP6A

3 to 6

76 to 152

 

 

 

 

DVP12A

3 to 12

76 to 305

 

 

 

DVP12MI

3 to 12

76 to 305

 

 

 

DVP24MI

3 to 24

76 to 610

 

 

 

 

 

 

 

11-3/8 in.

 

 

 

 

 

(289 mm)

10 in.

 

 

 

 

 

(254 mm)

10 in.

1 in.

 

 

 

(254 mm)

 

 

 

(25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

7-3/8 in.

24 in.

 

 

 

 

(187 mm)

 

 

 

 

 

(610 mm)

 

 

 

 

1-1/4 in. (32 mm)

 

 

 

 

 

 

 

 

 

9-1/4 in.

 

 

 

 

 

(235 mm)

1/2 in. TYP

 

 

 

 

13-1/4 in.

(13 mm)

 

 

 

 

 

 

 

 

 

(337 mm)

 

DVP-AS (Attic Shield)

DVP-FS (Ceiling Firestop)

DVP90ST (90° Elbow)

 

 

 

 

 

 

 

 

12 in.

1 in.

 

 

 

 

(305 mm)

(25 mm)

10 in.

1- 1/2 in.

 

 

 

8 in.

 

 

 

(203 mm)

(254 mm)

(38 mm)

 

14 in.

 

 

 

 

 

 

 

UP

 

 

(356 mm)

 

 

 

 

 

 

5 in.

12 in.

 

 

 

 

(127 mm)

(305 mm)

 

 

 

 

 

 

 

 

6 in.

 

 

 

 

 

(152 mm)

 

DVP-HVS (Vent Support)

 

 

 

DVP-WS (Wall Shield Firestop)

Figure 16.2 DVP vent components

 

 

 

 

 

 

Heat & Glo • Escape-42DV2052-900 Rev. R • 10/08

49

Image 49
Contents What to do if you smell gas ModelHot glass will cause burns Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Inspect Firebox Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseHearth Extension Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Vent Table Key Vent Information and DiagramsMeasuring Standards Use of ElbowsTop Vent Horizontal Termination One Elbow Vent DiagramsTwo Elbows H1+ H2Top Vent Horizontal Termination Three Elbows 12 ft V1 + V2 + H1 = 50 ft 15.2 m Max Ht Max Top Vent Vertical Termination Three ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Appliance Preparation Removing Non-combustible Facing Mate- rial AssemblySecuring and Leveling the Appliance Attaching Non-combustible Facing Material Installing Non-combustible Facing MaterialAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination flue of the pipe see Figure Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Intellifire Ignition System Wiring Recommendation for WireConnecting to the Appliance Optional Accessories RequirementsDetail a PVK-80 Motor Neutral Vacuum Switch 120VAC HOT Facing Material FinishingNon-combustible Finishing Material Requirements Finishing Materials RequirementsClean the Appliance Appliance SetupAccessories Ember PlacementStep Positioning the LogsLOG #2 SRV569-705 Two LOG #1 SRV750-706 ThreeLOG #4 SRV2012-162 LOG #3 SRV2052-701LOG #5 SRV2012-163 LOG #7 SRV2012-165 LOG #6 SRV2052-702LOG #8 SRV2012-166 Final StepAir Shutter Setting Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsOn position. The ON/OFF switch may Turn off all electric power to the applianceLighting Appliance IPI Ignition Final inspection byInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramLocation Inches Millimeters DVP vent components Vent Components DiagramsDVP-TRAP RF6M RF12M Service Parts Log Set AssemblyPart number list on following Stocked Service Parts ListAt Depot Stocked IPI Valve AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

ESCAPE-42DV specifications

Hearth and Home Technologies has established itself as a leader in the hearth industry, bringing innovation and style to homes across North America. One of their standout offerings is the ESCAPE-42DV, a versatile and efficient direct vent gas fireplace that combines modern design with cutting-edge technology.

The ESCAPE-42DV features a sleek, contemporary look that seamlessly integrates into various home aesthetics. With a viewing area of 42 inches, it provides a wide and inviting flame display that enhances the ambiance of any living space. Its generous size makes it an ideal centerpiece for larger rooms, allowing for a captivating focal point in homes with open floor plans.

One of the notable characteristics of the ESCAPE-42DV is its direct vent technology, which allows for efficient operation without the need for a traditional chimney. This system ensures that combustion gases are expelled outside while bringing in fresh air for combustion, creating a cleaner and more energy-efficient environment. Homeowners can enjoy the warmth and comfort of real flames without the hassle of maintaining a complex venting system.

Efficiency is key in today's eco-conscious world, and the ESCAPE-42DV exceeds expectations with its impressive energy ratings. It operates at a high efficiency level, providing excellent heating capability while minimizing gas consumption. This not only reduces utility bills but also makes it an environmentally friendly choice, appealing to those who prioritize sustainability.

Hearth and Home Technologies have also incorporated advanced features into the ESCAPE-42DV, including a variety of heat and flame control options. The unit comes equipped with a programmable remote control, allowing users to adjust the flame height and heat output with ease. This personalization ensures comfort whether homeowners are looking for a cozy ambiance or substantial warmth during colder months.

The fireplace can be styled according to individual preferences, thanks to customizable options such as various media choices, including beautiful ceramic logs and glowing embers. The ability to personalize the appearance of the ESCAPE-42DV enhances its appeal, making it a functional yet stylish addition to any home.

With its combination of design elegance, innovative technology, and operational efficiency, the Hearth and Home Technologies ESCAPE-42DV direct vent gas fireplace is an exceptional choice for homeowners seeking to elevate their living spaces. It stands as a testament to the brand's commitment to quality and innovation in the hearth industry, delivering warmth and beauty to modern homes.