9 Gas Information

A. Fuel Conversions

C. Gas Connection

Before making gas connections ensure that appliance be- ing installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a qualified technician using Hearth & Home Technologies specified and approved parts.

Note: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI

223.1.Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).

B. Gas Pressures

Proper input pressures are required for optimum appli- ance performance. Gas line sizing requirements need to be made following NFPA54.

WARNING

Fire Risk. Explosion Hazard.

High pressure will damage valve.

• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

WARNING

Verify inlet pressures.

• High pressure may cause overfire condition.

• Low pressure may cause explosion.

Verify minimum pressures when other household gas appliances are operating.

Install regulator upstream of valve if line pressure is greater than 1/2 psig.

Note: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 inch (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

Refer to Reference Section 16 for location of gas line access in appliance.

Note: Gas line may be run from either side of the appliance provided the hole in the outer wrap does NOT exceed 2-1/2 inches in diameter and does not penetrate the firebox.

WARNING

Gas Leak Risk

Support control when attaching pipe to prevent bending gas line.

NOTE: The gap between supply piping and gas access hole may be caulked with high temperature caulk or stuffed with non-combustible, unfaced insulation to prevent cold air infiltration.

Pressure requirements for appliance are shown in the table below. Minimum pressures must be met when other household gas appliances are operating.

Pressure

Natural Gas

Propane

Minimum inlet pressure

5.0 inches

11.0 inches

w.c.

w.c.

 

Maximum inlet gas pressure

14.0 inches

14.0 inches

w.c.

w.c.

 

Manifold pressure

3.5 inches

9.2 inches

w.c.

w.c.

 

28

Heat & Glo • Escape-42DV2052-900 Rev. R • 10/08

Image 28
Contents What to do if you smell gas ModelHot glass will cause burns Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Inspect Firebox Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections Hearth ExtensionVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Vent Information and Diagrams Vent Table KeyMeasuring Standards Use of ElbowsVent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows H1+ H2Top Vent Horizontal Termination Three Elbows 12 ft V1 + V2 + H1 = 50 ft 15.2 m Max Top Vent Vertical Termination Three Elbows Ht MaxVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Appliance Preparation Removing Non-combustible Facing Mate- rial AssemblySecuring and Leveling the Appliance Installing Non-combustible Facing Material Attaching Non-combustible Facing MaterialInstalling Vent Pipe Assembly of Vent SectionsAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Termination Cap flue of the pipe see FigureAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Intellifire Ignition System WiringConnecting to the Appliance Optional Accessories RequirementsDetail a PVK-80 Motor Neutral Vacuum Switch 120VAC HOT Finishing Facing MaterialFinishing Materials Requirements Non-combustible Finishing Material RequirementsAppliance Setup Clean the ApplianceAccessories Ember PlacementPositioning the Logs StepLOG #1 SRV750-706 Three LOG #2 SRV569-705 TwoLOG #4 SRV2012-162 LOG #3 SRV2052-701LOG #5 SRV2012-163 LOG #6 SRV2052-702 LOG #7 SRV2012-165LOG #8 SRV2012-166 Final StepGlass Assembly Air Shutter SettingRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceTurn off all electric power to the appliance On position. The ON/OFF switch mayLighting Appliance IPI Ignition Final inspection byInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsReference Materials Appliance Dimension DiagramLocation Inches Millimeters Vent Components Diagrams DVP vent componentsDVP-TRAP RF6M RF12M Service Parts Log Set AssemblyPart number list on following Stocked Service Parts ListAt Depot IPI Valve Assembly StockedCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

ESCAPE-42DV specifications

Hearth and Home Technologies has established itself as a leader in the hearth industry, bringing innovation and style to homes across North America. One of their standout offerings is the ESCAPE-42DV, a versatile and efficient direct vent gas fireplace that combines modern design with cutting-edge technology.

The ESCAPE-42DV features a sleek, contemporary look that seamlessly integrates into various home aesthetics. With a viewing area of 42 inches, it provides a wide and inviting flame display that enhances the ambiance of any living space. Its generous size makes it an ideal centerpiece for larger rooms, allowing for a captivating focal point in homes with open floor plans.

One of the notable characteristics of the ESCAPE-42DV is its direct vent technology, which allows for efficient operation without the need for a traditional chimney. This system ensures that combustion gases are expelled outside while bringing in fresh air for combustion, creating a cleaner and more energy-efficient environment. Homeowners can enjoy the warmth and comfort of real flames without the hassle of maintaining a complex venting system.

Efficiency is key in today's eco-conscious world, and the ESCAPE-42DV exceeds expectations with its impressive energy ratings. It operates at a high efficiency level, providing excellent heating capability while minimizing gas consumption. This not only reduces utility bills but also makes it an environmentally friendly choice, appealing to those who prioritize sustainability.

Hearth and Home Technologies have also incorporated advanced features into the ESCAPE-42DV, including a variety of heat and flame control options. The unit comes equipped with a programmable remote control, allowing users to adjust the flame height and heat output with ease. This personalization ensures comfort whether homeowners are looking for a cozy ambiance or substantial warmth during colder months.

The fireplace can be styled according to individual preferences, thanks to customizable options such as various media choices, including beautiful ceramic logs and glowing embers. The ability to personalize the appearance of the ESCAPE-42DV enhances its appeal, making it a functional yet stylish addition to any home.

With its combination of design elegance, innovative technology, and operational efficiency, the Hearth and Home Technologies ESCAPE-42DV direct vent gas fireplace is an exceptional choice for homeowners seeking to elevate their living spaces. It stands as a testament to the brand's commitment to quality and innovation in the hearth industry, delivering warmth and beauty to modern homes.