Hearth and Home Technologies ESCAPE-42DV owner manual Assembling Minimum Installations MI Sections

Page 23

Note: Make sure that the seams are not aligned to prevent unintentional disconnection.

CORRECT

Figure 8.4 Seams

INCORRECT

Assembling Minimum Installations (MI) Sections

MI sections are non-unitized so that they can be cut to a certain length. Cut these sections to length from the non- expanded end (see Figure 8.5).

They can then be attached by first connecting the expanded end of the MI inner flue with the inner pipe from the adjacent pipe section and securing with three screws. The expanded portion of the MI inner flue must overlap completely with the unexpanded end of the adjacent pipe section.

The outer flue can then be inserted into the adjacent outer flue expanded end and attached to the next pipe section with three screws. The other end of the MI pipe section can then be attached by fitting another pipe section to it and snapping it together, as normal.

Assembling DVP-12A Slip Sections

The outer flue of the slip section should slide over the outer flue of the pipe section and into (inner flue) the last pipe section (see Figure 8.6) .

Slide together to the desired length, making sure that a 1-1/2 inch outer flue overlap is maintained between the pipe section and slip section.

The pipe and slip section need to be secured by driving two screws through the overlapping portions of the outer flues using the pilot holes (see Figure 8.7).

This will secure the slip section to the desired length and prevent it from separating. The slip section can then be attached to the next pipe section.

If the slip section is too long, the inner and outer flues of the slip section can be cut to the desired length.

Cut from this end

(outer)

Cut from this end

(inner)

Figure 8.5

Pilot hole

Figure 8.6 Slip Section Pilot Holes

Figure 8.7 Screws into Slip Section

Heat & Glo • Escape-42DV2052-900 Rev. R • 10/08

23

Image 23
Contents Hot glass will cause burns ModelWhat to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Inspect Firebox Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseHearth Extension Mantel ProjectionsSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Use of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsH1+ H2 Vent DiagramsTop Vent Horizontal Termination One Elbow Two ElbowsTop Vent Horizontal Termination Three Elbows 12 ft V1 + V2 + H1 = 50 ft 15.2 m Max Ht Max Top Vent Vertical Termination Three ElbowsCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Securing and Leveling the Appliance Removing Non-combustible Facing Mate- rial AssemblyAppliance Preparation Attaching Non-combustible Facing Material Installing Non-combustible Facing MaterialAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Heat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap flue of the pipe see Figure Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Optional Accessories Requirements Recommendation for WireIntellifire Ignition System Wiring Connecting to the ApplianceDetail a PVK-80 Motor Neutral Vacuum Switch 120VAC HOT Facing Material FinishingNon-combustible Finishing Material Requirements Finishing Materials RequirementsEmber Placement Appliance SetupClean the Appliance AccessoriesStep Positioning the LogsLOG #2 SRV569-705 Two LOG #1 SRV750-706 ThreeLOG #5 SRV2012-163 LOG #3 SRV2052-701LOG #4 SRV2012-162 Final Step LOG #6 SRV2052-702LOG #7 SRV2012-165 LOG #8 SRV2012-166Replacing Glass Assembly Glass AssemblyAir Shutter Setting Removing Glass AssemblyBefore Lighting Appliance Operating InstructionsFinal inspection by Turn off all electric power to the applianceOn position. The ON/OFF switch may Lighting Appliance IPI IgnitionAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksLocation Inches Millimeters Appliance Dimension DiagramReference Materials DVP vent components Vent Components DiagramsDVP-TRAP RF6M RF12M Part number list on following Log Set AssemblyService Parts At Depot Service Parts ListStocked Stocked IPI Valve AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

ESCAPE-42DV specifications

Hearth and Home Technologies has established itself as a leader in the hearth industry, bringing innovation and style to homes across North America. One of their standout offerings is the ESCAPE-42DV, a versatile and efficient direct vent gas fireplace that combines modern design with cutting-edge technology.

The ESCAPE-42DV features a sleek, contemporary look that seamlessly integrates into various home aesthetics. With a viewing area of 42 inches, it provides a wide and inviting flame display that enhances the ambiance of any living space. Its generous size makes it an ideal centerpiece for larger rooms, allowing for a captivating focal point in homes with open floor plans.

One of the notable characteristics of the ESCAPE-42DV is its direct vent technology, which allows for efficient operation without the need for a traditional chimney. This system ensures that combustion gases are expelled outside while bringing in fresh air for combustion, creating a cleaner and more energy-efficient environment. Homeowners can enjoy the warmth and comfort of real flames without the hassle of maintaining a complex venting system.

Efficiency is key in today's eco-conscious world, and the ESCAPE-42DV exceeds expectations with its impressive energy ratings. It operates at a high efficiency level, providing excellent heating capability while minimizing gas consumption. This not only reduces utility bills but also makes it an environmentally friendly choice, appealing to those who prioritize sustainability.

Hearth and Home Technologies have also incorporated advanced features into the ESCAPE-42DV, including a variety of heat and flame control options. The unit comes equipped with a programmable remote control, allowing users to adjust the flame height and heat output with ease. This personalization ensures comfort whether homeowners are looking for a cozy ambiance or substantial warmth during colder months.

The fireplace can be styled according to individual preferences, thanks to customizable options such as various media choices, including beautiful ceramic logs and glowing embers. The ability to personalize the appearance of the ESCAPE-42DV enhances its appeal, making it a functional yet stylish addition to any home.

With its combination of design elegance, innovative technology, and operational efficiency, the Hearth and Home Technologies ESCAPE-42DV direct vent gas fireplace is an exceptional choice for homeowners seeking to elevate their living spaces. It stands as a testament to the brand's commitment to quality and innovation in the hearth industry, delivering warmth and beauty to modern homes.