F. Tools and Supplies Needed

Before beginning the installation be sure the following tools and building supplies are available:

Reciprocating saw

Framing material

Pliers

Non-combustible sealant

Hammer

Gloves

Phillips screwdriver

Framing square

Flat blade screwdriver

Electric drill and bits

Plumb line

Safety glasses

Level

Tape measure

1/2-3/4 in. length, #6 or #8 self-drilling screws Misc. screws and nails

G. Fireplace System Requirements

This fireplace system requires:

Hearth Refractory

Grate Assembly

Outside Air Hood

- Duct must be installed, but sold separately.

H. Inspect Fireplace and Components

WARNING! Risk of Fire and/or Explosion! Damaged parts could impair safe operation. DO NOT install dam- aged, incomplete or substitute components. Keep fire- place dry.

Remove fireplace and components from packaging (please refer to Section 7) and inspect for damage.

Vent system components and doors are shipped in separate packages.

Report to your dealer any parts damaged in shipment.

Read all the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.

Heat & Glo • EXCLAIM-36, EXCLAIM-424013-251 Rev C • 11/08

17

Image 17
Contents Fire Risk Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Number Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyHeat & Glo EXCLAIM-36, EXCLAIM-42 4013-251 Rev C 11/08 Appliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Starting a Fire Seasoned WoodGrate FirescreenVented Gas Log Sets & Gas Log Lighters Glass DoorsOptional Components Clear SpaceWood Fuel Chimney Inspection/Cleaning Maintainance and ServiceDisposal of Ashes Creosote Formation and Need for RemovalCheck Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedNegative Pressure Design and Installation ConsiderationsDraft Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Select Fireplace Location Framing & ClearancesClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsUnpack the Fireplace EXCLAIM-42 only Installation of FireplaceThings to Consider Unpack the Fireplace EXCLAIM-36 onlyRemoving Smoke Shield Position the Fireplace EXCLAIM-42 onlyGAS Knockout Install the Refractory EXCLAIM-42 onlyLevel Fireplace Place Protective Metal Hearth StripsYES Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssemble Chimney Sections Install Chimney Air KitInstalling the Ceiling Firestop Install Ceiling Firestops330 mm Install Attic Insulation ShieldInstall Flashing Complete InstallationFollowing steps should be skipped if using a chase Cut out Hole in RoofFlat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST1175/ST475 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Radiation Shield ShroudsField Constructed Shrouds Open Top Shroud TR11/TR11T caps require radiation shieldRoofed Style Shroud radiation shield required Mailbox Style Shroud radiation shield required= 1/k x inches of thickness FinishingHearth Extension Hearth Extension Construction Raised Hearth Extension FramingFlush Hearth Extension Framing Non-combustible SealantNoncombustible Facing Finishing MaterialCombustible Mantel 19 3/4 502 mm Gas Log/Lighter Provision AccessoriesWood Burning Inserts Gas Code, Ansi Z223.1Reference Materials Fireplace DimensionsEXCLAIM-36 EXCLAIM-42 Catalog # Chimney Components15-1/4 387 mm 15-3/4 400 mm CT56 Chase Top LDS33/LDS46 Decorative Shroud EXCLAIM-36H, EXCLAIM-36T Service PartsEXCLAIM-42H, EXCLAIM-42T This page intentionally left blank Do not Discard this Manual