Hearth and Home Technologies EXCLAIM-36 owner manual EXCLAIM-42H, EXCLAIM-42T

Page 54

54

Heat & Glo • EXCLAIM-36, EXCLAIM-424013-251 Rev C • 11/08

 

 

Service Parts

EXCLAIM-42H, EXCLAIM-42T

 

 

 

Service Parts Diagram

 

 

Beginning Manufacturing Date: March 2004

 

 

 

42 in. Woodburning Fireplace

 

 

 

Ending Manufacturing Date: Active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refractories

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Traditional

3

Herringbone

4

5

7

6

8

9

Part number list on following page.

06/08

 

 

Service Parts

EXCLAIM-42H, EXCLAIM-42T

 

 

 

Service Parts List

 

Beginning Manufacturing Date: March 2004

 

 

 

42 in. Woodburning Fireplace

 

 

Ending Manufacturing Date: Active

 

 

 

 

 

 

 

 

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement

 

 

 

Stocked

parts for your appliance please provide model number and serial number. All parts listed

 

in this manual may be ordered from an authorized dealer.

 

 

 

at Depot

ITEM

 

DESCRIPTION

 

COMMENTS

PART NUMBER

 

1

Starter Section Assembly

 

 

22072B

Y

2

Damper Blade Assembly

 

 

29964

N

3

Damper Control

 

 

20549

N

 

Damper Weight

 

 

19785A

N

4

Rear Top Standoff

 

Qty. 2 req.

19228

N

5

Front Top Standoff

 

Qty. 2 req.

11864i

N

6

Grate

 

 

GR38

Y

7

Upper Front

 

 

4013-207

N

 

Smoke Shield Kit

 

 

35406

Y

8

Smoke Shield

 

 

29946

N

 

Rear Smoke Shelf

 

 

35597

N

9

Firescreen Assembly

 

Qty. 2 req.

4013-121

Y

 

Firescreen Handle

 

1 ea.

4021-149

N

 

 

 

 

 

 

 

Firescreen Rod

 

Qty. 2 req.

28404

Y

 

Outside Air Kit

 

 

AK22

N

 

Fastener Pack

 

 

17916B

N

 

Outside Air Shield

 

 

33271

Y

 

4 in. Outside Air Inlet Ring

 

 

25692

N

 

Nailing Flange

 

Qty. 4 req.

31190

N

 

Refractory Retainer Kit

 

 

4013-090

N

 

Refractory Retainer

 

Qty. 3 req.

11847

N

 

Grate Retainer

 

Qty. 2 req.

4017-046

N

 

Screen Cover (top only)

 

Qty. 2 req.

29926

N

 

Strip Protector

 

Qty. 2 req.

18320

N

 

Side Trim

 

Qty. 2 req.

31326

N

 

Powder Coat Touch-Up Paint

 

 

71479

N

 

 

 

 

 

Herringbone Refractory (EXCLAIM-42H)

 

 

 

 

 

Herringbone Brick Refractory - Hearth

 

 

4013-058

N

 

Herringbone Brick Refractory - Left Side

 

 

4013-056

N

 

Herringbone Brick Refractory - Right Side

 

 

4013-055

N

 

Herringbone Brick Refractory - Back

 

 

4013-061

N

Herringbone Refractory (EXCLAIM-42H)

 

 

 

 

 

Traditional Brick Refractory - Hearth

 

 

4013-058

N

 

Traditional Brick Refractory - Side

 

Qty. 2 req.

4013-052

N

 

Traditional Brick Refractory - Back

 

 

4013-059

N

 

 

 

 

 

 

 

Installation Instructions & Owner's Manual

 

 

4013-251

N

 

 

 

 

 

 

 

06/08

D. Service Parts (continued)

Image 54
Contents Wood Burning Fireplace Hot screen/mesh and glass doors will cause burnsFire Risk Listing Label Information/Location GrateNumber Table of Contents Installer GuideUser Guide Warranty Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHeat & Glo EXCLAIM-36, EXCLAIM-42 4013-251 Rev C 11/08 Non-Combustible Materials Listing and Code ApprovalsAppliance Certification Combustible MaterialsOperating Instructions Your FireplaceHot glass will cause burns Grate Seasoned WoodStarting a Fire FirescreenOptional Components Glass DoorsVented Gas Log Sets & Gas Log Lighters Clear SpaceWood Fuel Disposal of Ashes Maintainance and ServiceChimney Inspection/Cleaning Creosote Formation and Need for RemovalInspect Grate Glass CleaningCheck Firebox Refractory Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemDesign and Installation Considerations DraftNegative Pressure Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsTools and Supplies Needed Fireplace System RequirementsInspect Fireplace and Components Framing & Clearances Select Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceThings to Consider Installation of FireplaceUnpack the Fireplace EXCLAIM-42 only Unpack the Fireplace EXCLAIM-36 onlyPosition the Fireplace EXCLAIM-42 only Removing Smoke ShieldInstall the Refractory EXCLAIM-42 only GAS KnockoutPlace Protective Metal Hearth Strips Level FireplaceInstall Outside Air Kit YESChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleInstall Chimney Air Kit Assemble Chimney SectionsInstall Ceiling Firestops Installing the Ceiling FirestopInstall Attic Insulation Shield 330 mmFollowing steps should be skipped if using a chase Complete InstallationInstall Flashing Cut out Hole in RoofChimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST1175/ST475 Square Termination CapTCT1175 Terra Cotta Cap Field Constructed Shrouds ShroudsRadiation Shield Open Top Shroud TR11/TR11T caps require radiation shieldMailbox Style Shroud radiation shield required Roofed Style Shroud radiation shield requiredFinishing Hearth Extension= 1/k x inches of thickness Raised Hearth Extension Framing Hearth Extension ConstructionNon-combustible Sealant Flush Hearth Extension FramingFinishing Material Noncombustible FacingCombustible Mantel 19 3/4 502 mm Wood Burning Inserts AccessoriesGas Log/Lighter Provision Gas Code, Ansi Z223.1Fireplace Dimensions Reference MaterialsEXCLAIM-36 EXCLAIM-42 Chimney Components Catalog #15-1/4 387 mm 15-3/4 400 mm CT56 Chase Top LDS33/LDS46 Decorative Shroud Service Parts EXCLAIM-36H, EXCLAIM-36TEXCLAIM-42H, EXCLAIM-42T This page intentionally left blank Do not Discard this Manual