Hearth and Home Technologies EXCLAIM-36 Chimney Requirements, Height of Chimney Components

Page 27

A. Chimney Requirements

Measure vertical distances from the base of the fireplace as shown in Figure 8.2.

 

ft

m

• Minimum overall straight height

18

5.49

• Minimum height with offset/return

18.5

5.64

• Maximum height

90

27.43

• Maximum chimney length between an

20

6.10

offset and return

 

 

• Maximum distance between chimney

35

10.67

stabilizers`

 

 

• Double offset/return minimum height

24

7.32

• Maximum unsupported chimney length

6

1.83

between the offset and return

 

 

• Maximum unsupported chimney height

35

10.67

above the fireplace

 

 

• Maximum unsupported chimney above

6

1.83

roof

 

 

WARNING! Risk of Fire! You must maintain 2 in. (51

mm)air space clearance to insulation and other combus- tible materials around the chimney system. Failure to do so may cause overheating and fire.

Determine the chimney components needed to complete your particular installation:

Measure the total vertical height of the fireplace installation from the base of the fireplace assembly to the approximate location of the bottom of the termination cap.

Subtract the effective height of the fireplace assembly (see Figure 8.2) from the total vertical height to determine the overall height of the chimney installation.

Create a schematic for your application similar to Figure 8.2 showing components required (referring to Table 8.1). Figure 8.1 identifies those components and where used.

Install a ceiling firestop whenever the chimney penetrates a floor/ceiling.

NOTICE: A maximum of two pairs of offsets and returns may be used.

CAUTION! Risk of Fire and/or Asphyxiation! DO NOT connect this fireplace to a chimney flue servicing another appliance. DO NOT connect to any air distribu- tion duct or system. These actions could cause over- heating/fire in the chimney flue, or release of exhaust fumes into the living areas.

Î Table 8.1

HEIGHT OF CHIMNEY COMPONENTS

in.

mm

US

 

Canada ONLY

 

 

Chimney Stabilizer

 

 

 

SL11

 

SL4

4-3/4

121

Ceiling Firestops

 

 

 

FS538

 

FS538

0

0

 

 

 

 

 

FS540

 

FS540

0

0

Offsets/Returns

 

 

 

SL1130

 

SL430

14-1/2

368

Roof Flashing

 

 

 

RF570

 

RF570

0

0

RF571

 

RF571

0

0

Chimney Sections*

 

 

 

SL1106

 

SL406

4-3/4

121

SL1112

 

SL412

10-3/4

273

 

 

 

 

 

SL1118

 

SL418

16-3/4

425

SL1136

 

SL436

34-3/4

883

 

 

 

 

 

SL1148

 

SL448

46-3/4

1187

 

 

 

 

 

n/a

 

SLA10

16-3/4

425

* Dimensions reflect effective height.

6 ft (1.8 m) max. unsupported run

20 ft (6 m) max. pipe between an offset & return

Ceiling Firestop

11-10 in./279-254mm adaptor required in Canada

55-1/2 in.

(1410 mm)

Effective Height

(bottom of fireplace

to top of starter collar)

6 ft (1.8 m) max. unsupported chimney above roof

35 ft (10.7 m) max. straight unsupported chimney height

18.5ft (5.6 m) min. height single offset-return

24 ft. (7.3 m) min. height

double offset-return

90 ft (27.4 m) max. height

Figure 8.2 Chimney Requirements

Heat & Glo • EXCLAIM-36, EXCLAIM-424013-251 Rev C • 11/08

27

Image 27
Contents Wood Burning Fireplace Hot screen/mesh and glass doors will cause burnsFire Risk Listing Label Information/Location GrateNumber Table of Contents Installer GuideUser Guide CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyHeat & Glo EXCLAIM-36, EXCLAIM-42 4013-251 Rev C 11/08 Combustible Materials Listing and Code ApprovalsAppliance Certification Non-Combustible MaterialsOperating Instructions Your FireplaceHot glass will cause burns Firescreen Seasoned WoodStarting a Fire GrateClear Space Glass DoorsVented Gas Log Sets & Gas Log Lighters Optional ComponentsWood Fuel Creosote Formation and Need for Removal Maintainance and ServiceChimney Inspection/Cleaning Disposal of AshesFrequency As desired Glass CleaningCheck Firebox Refractory Inspect GrateStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDesign and Installation Considerations DraftNegative Pressure Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyTools and Supplies Needed Fireplace System RequirementsInspect Fireplace and Components Select Fireplace Location Framing & ClearancesClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsUnpack the Fireplace EXCLAIM-36 only Installation of FireplaceUnpack the Fireplace EXCLAIM-42 only Things to ConsiderRemoving Smoke Shield Position the Fireplace EXCLAIM-42 onlyGAS Knockout Install the Refractory EXCLAIM-42 onlyLevel Fireplace Place Protective Metal Hearth StripsYES Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssemble Chimney Sections Install Chimney Air KitInstalling the Ceiling Firestop Install Ceiling Firestops330 mm Install Attic Insulation ShieldCut out Hole in Roof Complete InstallationInstall Flashing Following steps should be skipped if using a chaseFlat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST1175/ST475 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Open Top Shroud TR11/TR11T caps require radiation shield ShroudsRadiation Shield Field Constructed ShroudsRoofed Style Shroud radiation shield required Mailbox Style Shroud radiation shield requiredFinishing Hearth Extension= 1/k x inches of thickness Hearth Extension Construction Raised Hearth Extension FramingFlush Hearth Extension Framing Non-combustible SealantNoncombustible Facing Finishing MaterialCombustible Mantel 19 3/4 502 mm Gas Code, Ansi Z223.1 AccessoriesGas Log/Lighter Provision Wood Burning InsertsReference Materials Fireplace DimensionsEXCLAIM-36 EXCLAIM-42 Catalog # Chimney Components15-1/4 387 mm 15-3/4 400 mm CT56 Chase Top LDS33/LDS46 Decorative Shroud EXCLAIM-36H, EXCLAIM-36T Service PartsEXCLAIM-42H, EXCLAIM-42T This page intentionally left blank Do not Discard this Manual