Hearth and Home Technologies EXCLAIM-36 owner manual TCT1175 Terra Cotta Cap

Page 37

TCT1175 Terra Cotta Cap

Collar

2 in. (51 mm)

Minimum Height

Chase Top

Place waterproof sealer under each flange of the termina- tion cap and on top of each screw to help prevent leaks.

Termination Cap

The last section of pipe must stop between 2 in. (51 mm) above top of chase and 7 in. (178 mm) below top of chase

2 in. (51 mm)

7 in. (178 mm

Chase

Chimney

Pipe

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Figure 9.7 Installing a TCT1175 Terra Cotta Cap

Heat & Glo • EXCLAIM-36, EXCLAIM-424013-251 Rev C • 11/08

37

Image 37
Contents Hot screen/mesh and glass doors will cause burns Wood Burning FireplaceFire Risk Grate Listing Label Information/LocationNumber Installer Guide Table of ContentsUser Guide CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyHeat & Glo EXCLAIM-36, EXCLAIM-42 4013-251 Rev C 11/08 Appliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsYour Fireplace Operating InstructionsHot glass will cause burns Starting a Fire Seasoned WoodGrate FirescreenVented Gas Log Sets & Gas Log Lighters Glass DoorsOptional Components Clear SpaceWood Fuel Chimney Inspection/Cleaning Maintainance and ServiceDisposal of Ashes Creosote Formation and Need for RemovalCheck Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDraft Design and Installation ConsiderationsNegative Pressure Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyFireplace System Requirements Tools and Supplies NeededInspect Fireplace and Components Select Fireplace Location Framing & ClearancesClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsUnpack the Fireplace EXCLAIM-42 only Installation of FireplaceThings to Consider Unpack the Fireplace EXCLAIM-36 onlyRemoving Smoke Shield Position the Fireplace EXCLAIM-42 onlyGAS Knockout Install the Refractory EXCLAIM-42 onlyLevel Fireplace Place Protective Metal Hearth StripsYES Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssemble Chimney Sections Install Chimney Air KitInstalling the Ceiling Firestop Install Ceiling Firestops330 mm Install Attic Insulation ShieldInstall Flashing Complete InstallationFollowing steps should be skipped if using a chase Cut out Hole in RoofFlat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST1175/ST475 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Radiation Shield ShroudsField Constructed Shrouds Open Top Shroud TR11/TR11T caps require radiation shieldRoofed Style Shroud radiation shield required Mailbox Style Shroud radiation shield requiredHearth Extension Finishing= 1/k x inches of thickness Hearth Extension Construction Raised Hearth Extension FramingFlush Hearth Extension Framing Non-combustible SealantNoncombustible Facing Finishing MaterialCombustible Mantel 19 3/4 502 mm Gas Log/Lighter Provision AccessoriesWood Burning Inserts Gas Code, Ansi Z223.1Reference Materials Fireplace DimensionsEXCLAIM-36 EXCLAIM-42 Catalog # Chimney Components15-1/4 387 mm 15-3/4 400 mm CT56 Chase Top LDS33/LDS46 Decorative Shroud EXCLAIM-36H, EXCLAIM-36T Service PartsEXCLAIM-42H, EXCLAIM-42T This page intentionally left blank Do not Discard this Manual