5100-I WOOD INSERT
Tested and | Beaverton | |
Listed by | Oregon USA |
C
This manual contains instructions for Installation, Operation & Maintenance. Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death.
IMPORTANT SAFETY NOTES:
1)When installing your insert, particular attention should be paid to fire protection. If this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building, fire officials or authority having jurisdiction about restrictions,installation inspection and permits requirements in your area.
2)CAUTION: Never use gasoline,
3)During operation, if any part of the insert starts to glow, the insert is in an overfired condition. Close the air controls completely by pulling them out, until the glowing has stopped. OVERFIRING VOIDS YOUR WARRANTY!
4)Cool ashes should be disposed of carefully, using a metal container.
5)Do not burn wet or green wood. Store wood in a dry location.
6)DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL. Do not burn treated wood, or wood with salt (driftwood, etc.). Burning materials other than wood (including charcoal) under adverse conditions may generate carbon monoxide in the home, resulting in illness or possible death.
7)Do not permit creosote or soot to accumulate excessively in the chimney or inside the firebox.
8)Check your chimney system thoroughly when installing into an existing metal or masonry chimney. Seek professional advice if in doubt about its condition.
9)Do not connect this unit to a chimnney flue already serving another appliance.
10)Comply with all minimum clearances to combustibles as shown in this manual for this appliance.
11)Build fire on brick firebox floor. Do not use grates, andirons or other methods to support fuel.
12)HOT WHILE IN OPERATION! Keep children, pets, clothing and furniture away. Contact can cause skin burns.
13)Do not connect to any air distribution duct or system.
14)RISK OF FIRE! Do not operate with insert door open. Operating with door open could result in overfiring.
15)For further information refer to NFPA 211 (US) or
16)Do not operate without fully assembling all components.
17)Do not operate with broken glass.
PRIOR TO FIRST FIRE: Remove all labels from glass. Clean plated surfaces with a glass cleanser and soft cloth
to prevent staining from fingerprint oils.
SAVE THESE INSTRUCTIONS