Hearth and Home Technologies 5100-I Installation in Canada, USE of Leveling Bolts

Page 12

R

5100-I WOOD INSERT

INSTALLATION IN CANADA

MASONRY and HEAT-CIRCULATING

(INSTALLATIONS INTO FACTORY-BUILT FIREPLACES ARE PROHIBITED IN CANADA)

Whether installed in a masonry or heat-circulating fireplace, this fireplace insert must be installed with a continuous chim- ney liner of 6” (152mm) diameter extending from the fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirements of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.

Do not remove bricks or mortar from fireplace to accommodate insert.

The face of the fireplace must be sealed to prevent room air passage into the chimney cavity.

The permanent metal warning label provided must be affixed to the back of the fireplace with screws or nails to the fireplace, in a location readily visible should the fireplace insert by removed, stating that the fireplace may have been altered to accommodate the insert, and must be returned to original condition for use as a conventional fireplace.

USE OF LEVELING BOLTS

Two leveling bolts, 3/8” x 4” are shipped inside the component pack found inside the firebox.

NOTE: Not all installations will require the use of the leveling bolts. If the leveling bolts are necessary, you will also need sheetmetal guides placed under the leveling bolts to slide insert into position.

1.Remove the bolts from the component pack.

2.Locate the weld nuts welded to each side of the insert bottom and insert the bolts.

3.Position insert on hearth with rear of insert extending into fireplace opening.

4.Extend leveling bolts downward to level insert.

SECURING LINER TO CHIMNEY RING

There are two options to secure the liner to the chim- ney ring: (See Figure 12A).

Option One: If there is enough room on the top of the insert to work, hand bend the two tabs upward 90°. Secure the liner with the supplied hex head bolts 1/4- 20-3/4.

Option Two: Remove the manifold tubes, fiberboard baffle and ceramic blanket. From inside the firebox, pull liner down through the chimney ring below the outer skin. There are two pre-drilled holes in the chim- ney ring 180° apart. Secure the liner with the supplied hex head bolts 1/4-20-3/4.

NOTE: Tabs are shipped from factory in a flat position. Bend upwards 90 degrees.

2 pre-drilled holes on chimney ring under outer skin (access through firebox)

Figure 12A

Page 12

250-1960 Rev B

January 30, 2004

Image 12
Contents Wood Insert Wood Insert Dan HenryWood Insert Safety & Overview of Appliance TOP View Side ViewWood Insert Clearances to Combustibles Thermal Protection USA & CanadaInstallation Recommendations ListingsChimney HEIGHT/DRAFT General Installation Procedure Alternate Floor Protection WorksheetChimney Requirements Ovalizing Round Stainless Steel LinersChimney Height Chimney TOP ViewInstallations Into Zero Clearance Fireplaces in Mobile Homes Installation Options Masonry Fireplace Using DIRECT-CONNECT MethodUSA Installatons only Factory Built Zero Clearance FireplaceInstallation in Canada USE of Leveling BoltsSecuring Liner to Chimney Ring Outside AIR Installation Blower OperationBlower Cord Location Blower Replacement Instructions Wiring DiagramFAN Speed Control ADJUSTMENT, if Necessary Panel and Trim SET Installation Zero Clearance Adjustable Trim SUPPORT, 2 to Overfiring Building a FireWood Selection and Storage Wood Insert Operating Tips FAN Operating InstructionsASH Removal AIR Quality and Your QUADRA-FIRE Insert Story of the Three Burning StagesMaintenance Brick Replacement Instructions Baffle Brick Removal & InstallationAccessories Service PartsAppliances Lifetime Warranty Rev B January 30