5100-I WOOD INSERT

PANEL and TRIM SET INSTALLATION

STANDARD Size: 30-1/2” h x 47”w

LARGE Size: 34-1/4” h x 51-1/4”w

831-1452, Gold Trim

831-1461, Gold Trim

SP-51S-NL, Nickel Trim

SP-51l-NL, Nickel Trim

Kit Includes: (2) Side Panels, left & right; (1) Panel Top & Fastener package; (2) Side Trim, left & right; (1) Trim Top & Fastener package.

Tools Needed: Powered Phillips head screw driver and a long handled Phillips screw driver .

Attaching Panels to the Insert

1.Loosely install the 2 side panels, do not tighten, using the cage nuts already attached to the stove. (Note: The sides are not interchangeable).

2.Put top panel in place pushing straight back and then to the right to lock onto top of side panels. Attach the top panel to the sides using the screw already installed at the top of side panels and the panel brackets included in the fasteners package.

3.Tighten side panels to the stove using a long handle screw driver. See Figure 15B.

Panel brackets

Do not tighten sides until top is locked into place

Figure 15A

Back view of top and side panel assembled

Assembling Trim

1.Place protective covering on surface to be used to assemble the trim pieces. Lay the trim face down.

2.Attach the 2 side trim pieces to the top trim at each corner using the “L” bracket included in fasteners package. Slide assembled trim over panel set. See Figure 15C.

View of "L" Bracket

installed

Figure 15C

Figure 13B

January 30, 2004

250-1960 Rev B

Page 15

Image 15
Contents Wood Insert Dan Henry Wood InsertWood Insert Safety & Overview of Appliance Side View TOP ViewThermal Protection USA & Canada Wood Insert Clearances to CombustiblesInstallation Recommendations ListingsChimney HEIGHT/DRAFT Alternate Floor Protection Worksheet General Installation ProcedureChimney TOP View Chimney RequirementsOvalizing Round Stainless Steel Liners Chimney HeightInstallations Into Zero Clearance Fireplaces in Mobile Homes Masonry Fireplace Using DIRECT-CONNECT Method Installation OptionsFactory Built Zero Clearance Fireplace USA Installatons onlyInstallation in Canada USE of Leveling BoltsSecuring Liner to Chimney Ring Outside AIR Installation Blower OperationBlower Cord Location Blower Replacement Instructions Wiring DiagramFAN Speed Control ADJUSTMENT, if Necessary Panel and Trim SET Installation Zero Clearance Adjustable Trim SUPPORT, 2 to Overfiring Building a FireWood Selection and Storage Wood Insert Operating Tips FAN Operating InstructionsASH Removal Story of the Three Burning Stages AIR Quality and Your QUADRA-FIRE InsertMaintenance Baffle Brick Removal & Installation Brick Replacement InstructionsAccessories Service PartsAppliances Lifetime Warranty Rev B January 30