DISCHARGE

Install a tee at the discharge connection of the pump. The top opening of the tee is required for initial priming. See Figure 1.

PRIMING OPENING

FUSED OR

 

CIRCUIT BREAKER

 

DISCONNECT MEANS

UNION

 

SUCTION

Rotation

NOTICE: INCORRECT ROTATION MAY CAUSE DAMAGE TO THE PUMP AND VOIDS THE WARRANTY.

Correct rotation is right hand, CLOCKWISE when viewed from the motor end.

Three phase unit rotation may be checked by removing motor end cap or plug and observing rotation of motor shaft. To reverse rotation, reverse any two of the three motor leads.

Operation

Figure 1

Wiring and Grounding

WARNING

OPERATION WITHOUT PRIME, OR AGAINST A CLOSED DISCHARGE VALVE, CAN GENERATE HOT WATER OR STEAM CAUSING

WARNING

Install, ground and wire according to local and National Electrical Code requirements.

Install an all leg electrical power disconnect switch near the

Extreme heat can cause personal injury or property damage

INJURY OR PROPERTY DAMAGE.

NOTICE: DO NOT OPERATE PUMP WITHOUT PRIME OR SEAL DAMAGE WILL RESULT.

Hazardous voltage can shock, burn or cause death.

pump.

Disconnect electrical power before installing or servicing pump.

Prime pump by filling pump and piping through opening in top of tee with clean water. See Figure 1.

Install pipe plug in top of tee using TeflonTM tape or equivalent.

Electrical supply MUST match pump’s nameplate specification. Incorrect voltage can cause fire or damage to the motor and voids warranty.

Motors without built-in protection MUST be provided with contactors and thermal overloads for single phase motors, or starters with heaters for three phase motors. See motor nameplate.

Follow motor manufacturer’s wiring diagram on the

motor nameplate or terminal cover carefully.

NOTICE: IF PUMP IS DRAINED OR SHUT OFF DURING PRIMING PERIOD, CASING MUST BE REFILLED BEFORE RESTARTING PUMP.

Start the pump and partially open discharge valve and wait for system pressure to stabilize. If system pressure is surging, or prolonged pressure drop is experienced, the system may not be completely primed.

Maintenance

Use only copper wire to motor and ground. The ground

wire MUST be at least as large as the wire to the motor.

Wires should be color coded for ease of maintenance.

RECOMMENDED MINIMUM WIRE SIZE

 

 

 

Distance from Service Entrance to Motor

 

HP

50 Ft. (15 m)

100 Ft. (30 m)

150 Ft. (46 m)

200 Ft. (61 m)

 

 

 

 

 

 

 

 

 

 

115 V

230 V

115 V

230 V

115 V

230 V

115 V

230 V

34

12

14

10

14

8

14

6

12

WARNING

Hazardous voltage can shock, burn or cause death.

FAILURE TO DISCONNECT ELECTRICAL POWER BEFORE ATTEMPTING ANY MAINTENANCE CAN CAUSE SHOCK, BURNS OR DEATH.

No lubrication is required on pump. For motor lubrication, refer to and follow manufacturer’s instructions.

1

12

14

8

14

8

12

6

12

 

112

10

14

8

14

12

10

2

10

14

8

14

12

10

3

12

12

10

10

 

 

 

FAILURE TO PERMANENTLY

 

 

WARNING

 

 

GROUND THE PUMP, MOTOR AND

 

Hazardous

 

CONTROLS BEFORE CONNECTING

 

voltage

 

 

 

TO ELECTRICAL POWER CAN

 

 

 

 

 

 

 

 

CAUSE SHOCK, BURNS, OR DEATH.

SEASONAL SERVICE

To REMOVE pump from service, remove all drain plugs and drain all piping.

To RETURN pump to service, replace all drain plugs using TeflonTM tape or equivalent.

Reconnect suction line if removed, examine union and repair if necessary.

Reprime and operate pump following all instructions and warnings in the “OPERATION” section of manual.

3

Image 3
Contents IRRI-GATOR Models and Owner’s Information Table of ContentsPiping Safety InstructionsDescription and Specifications Engineering DataOperation Wiring and Grounding MaintenanceRotation Symptom DisassemblyReassembly Trouble ShootingElectrical Data Repair Parts ListPage Page This Warranty Extends to the Dealer only Índice Modelos e información del propietarioTuberías Instrucciones de seguridadDatos de ingeniería Descripción y especificacionesRotación Operación Alambrado y conexión a tierraMantenimiento Desensamblaje Reensamblaje Identificación y resolución de problemas SíntomaCausas Probables Lista de partes de repuesto Datos eléctricosNotas LA Presente Garantía SE Extiende AL Comerciante Únicamente Table des matières Modèle et informations pour le propriétaireDescription et caractéristiques Consignes de sécuritéDonnées techniques TuyauterieSens de rotation Utilisation Câblage et mise à la terreEntretien Anomalie Diagnostic des anomaliesDémontage RemontageListe de pièces de rechange Données sur l’alimentation électriquePage Page Cette Garantie SE Rapporte AU Détaillant Seulement

GT07, GT15, GT10, GT20, GT30 specifications

The ITT GT series, comprising models GT30, GT20, GT10, GT15, and GT07, is renowned for its advanced engineering and superior performance in the realm of industrial and commercial applications. Each model in the GT series represents a unique blend of technology and design aimed at meeting diverse operational requirements.

The ITT GT30 is one of the flagship models of the series, recognized for its robust performance and reliability. It features a high-capacity design, capable of delivering significant power while maintaining energy efficiency. Key technologies integrated into the GT30 include advanced cooling systems and precision engineering of components, which help minimize wear and tear, thus extending the lifespan of the unit.

The GT20 model stands as a versatile option, striking a balance between power and compact design. With its flexible configuration and modular design, the GT20 can adapt to various settings, making it ideal for applications where space is a constraint. The inclusion of smart technology allows for real-time monitoring, ensuring optimal performance and minimal downtime.

The GT10 model is tailored for those who prioritize efficiency without compromising on output. This model emphasizes energy-saving features, thus making it an excellent choice for eco-conscious businesses. The GT10 is equipped with state-of-the-art power management systems that optimize energy use while delivering consistent performance across multiple applications.

The GT15 combines the strengths of both the GT20 and GT10, offering a balanced solution for mid-range applications. Its design focuses on ease of installation and maintenance, which operators will find advantageous as it reduces operational disruptions. The GT15 also supports advanced connectivity options, providing users with greater control and oversight.

Lastly, the GT07 serves as the entry-level model in the ITT GT series. Despite its smaller size, the GT07 does not compromise on performance. It is engineered for user-friendly operation and reliability, making it suitable for smaller operations or as a supplemental unit in larger systems. The advancements in digital technology embedded within the GT07 ensure that it meets modern standards for performance and safety.

Overall, the ITT GT series epitomizes innovation and quality, with each model designed to cater to specific needs in an ever-evolving industrial landscape. Whether it’s for heavy-duty applications or more compact needs, the GT series delivers an impressive array of features and specifications that underline ITT's commitment to excellence in engineering.